Background: Damage to the tricuspid valve (TVD) is now considered either a major or minor complication of the transvenous lead extraction procedure (TLE). As yet, the risk factors and long-term survival after TLE in patients with TVD have not been analyzed in detail. Methods: This post hoc analysis used clinical data of 2631 patients (mean age 66.86 years, 39.64% females) who underwent TLE procedures performed in three high-volume centers. The risk factors and long-term survival of patients with worsening tricuspid valve (TV) function after TLE were analyzed. Results: In most procedures (90.31%), TLE had no negative influence on TV function, but in 9.69% of patients, a worsening of tricuspid regurgitation (TR) to varying degrees was noted, including significant dysfunction in 2.54% of patients. Risk factors of TLE relating to severe TVD were: TLE of pacing leads (5.264; p = 0.029), dwell time of the oldest extracted lead (OR = 1.076; p = 0.032), strong connective scar tissue connecting a lead with tricuspid apparatus (OR = 5.720; p < 0.001), and strong connective scar tissue connecting a lead with the right ventricle wall (OR = 8.312; p < 0.001). Long-term survival (1650 ± 1201 [1–5519] days) of patients with severe TR was comparable to patients without tricuspid damage related to TLE. Conclusions: Severe tricuspid valve damage related to TLE is relatively rare (2.5%). The main risk factors for the worsening of TV function are associated with a longer lead dwell time (more often the pacing lead), causing stronger connective tissue scars connecting the lead to the tricuspid apparatus and right ventricle. TVD is unlikely to affect long-term survival after TLE.
Background: Lead-related tricuspid valve dysfunction (LDTVD) has not been studied in a large population and its management remains controversial. Methods: An analysis of the clinical data of 2678 patients undergoing transvenous lead extraction (TLE) in years 2008–2021 was conducted, with a separate group of 119 patients with LDTVD. Potential risk factors for LDTVD, improvement in valve function, and long-term prognosis after TLE were assessed. Results: LDTVD was diagnosed in 4.44% of patients referred for lead extraction due to different reasons. The most common mechanism of LDTVD was propping upward or clamping down the leaflet by the lead (85.71%). The probability of LDTVD was higher in female sex, patients with valvular heart disease, atrial fibrillation, heart failure, large right ventricle and high pulmonary artery systolic pressure, the presence of only pacing lead, and in case of collision of the lead with tricuspid valve and adhesion of the lead to the heart structures. The prognosis of patients with LDTVD was worse, however, patients with improved valve function after TLE showed a significantly better long-term survival. Conclusions: Lead dependent tricuspid valve dysfunction is a potentially serious condition that requires thorough diagnostics and thoughtful management. The risk factors for LDTVD are primarily related to the course of the lead and its adhesion to the heart structures. Improvement of tricuspid valve function after TLE is observed in 35.29% of patients Patients with LDTVD have a worse long-term survival, but the improvement in valve function following TLE contributes to a significant reduction in mortality.
Background: Transesophageal echocardiography (TEE) is a valuable tool for monitoring the patient during transvenous lead extraction (TLE), but the direct impact of TEE on the effectiveness and safety of TLE has not yet been documented. Methods: The effectiveness of TLE and short-term survival were compared between two groups of patients: 2106 patients in whom TEE was performed before and after TLE and 1079 individuals in whom continuous TEE monitoring was used. The procedure-related risk of major complications was assessed using a predictive SAFeTY TLE score. Results: The patients monitored by TEE were characterized by older age, more comorbidities and higher SAFeTY TLE scores (6.143 ± 4.395 vs. 5.593 ± 4.127; p = 0.004). Complete procedural success was significantly higher in the TEE-guided group (97.683% vs. 95.442%, p < 0.01). The rate of serious complications in the TEE-guided group was lower than the predictive SAFeTY TLE score—a reduction of 28.75% (p < 0.05). Periprocedural mortality in the TEE-guided and non-TEE-guided groups was zero vs. six deaths (p = 0.186). Short-term survival was comparable between the groups. Conclusions: Transesophageal echocardiography as a monitoring tool during transvenous lead extraction provides valuable results—higher rates of complete procedural success and a reduced risk of the most severe complications, thus preventing periprocedural deaths.
Background: Implantable cardioverter-defibrillator (ICD) leads are considered a risk factor for major complications (MC) during transvenous lead extraction (TLE). Methods: We analyzed 3878 TLE procedures (including 1051 ICD lead extractions). Results: In patients with ICD lead removal, implant duration was almost half as long (69.69 vs. 114.0 months; p < 0.001), procedure complexity (duration of dilatation of all extracted leads, use of more advanced tools or additional venous access) (15.13% vs. 20.78%; p < 0.001) and MC (0.67% vs. 2.62%; p < 0.001) were significantly lower as compared to patients with pacing lead extraction. The procedural success rate was higher in these patients (98.29% vs. 94.04%; p < 0.001). Extraction of two or more ICD leads or additional superior vena cava (SVC) coil significantly prolonged procedure time, increased procedure complexity and use of auxiliary or advanced tools but did not influence the rate of MC. The type of ICD lead fixation and tip position did not affect TLE complexity, complications and clinical success although passive fixation reduces the likelihood of procedural success (OR = 0.297; p = 0.011). Multivariable regression analysis showed that ICD lead implant duration ≥120 months (OR = 2.956; p < 0.001) and the number of coils in targeted ICD lead(s) (OR = 2.123; p = 0.003) but not passive-fixation ICD leads (1.361; p = 0.149) or single coil ICD leads (OR = 1.540; p = 0.177) were predictors of higher procedure complexity, but had no influence on MC or clinical and procedural success. ICD lead implant duration was of crucial importance, similar to the number of leads. Lead dwell time >10 years is associated with a high level of procedure difficulty and complexity but not with MC and procedure-related deaths. Conclusions: The main factors affecting the transvenous removal of ICD leads are implant duration and the number of targeted ICD leads. Dual coil and passive fixation ICD leads are a bit more difficult to extract whereas fixation mechanism and tip position play a much less dominant role.
Background: Patients with infectious complications related to the presence of cardiac implantable electronic devices (CIED) constitute a heterogeneous group, ranging from local pocket infection (PI) to lead-related infectious endocarditis (LRIE) infection spreading along the leads to the endocardium. The detection of isolated LRIE and the assessment of the spread of infection in a patient with PI is often difficult and requires complex imaging and microbiological tests. The aim of the current study is to evaluate the usefulness of new simple hematological parameters in detecting infectious complications in patients with CIED, differentiating vegetation and vegetation-like masses, and assessing the extent of infections in patients with PI. Methods: A retrospective analysis of clinical data of 2909 patients (36.37% with CIED-related infections), undergoing transvenous lead extraction (TLE) procedures in three high-volume centres in the years 2006–2020, was conducted. Receiver operating characteristic (ROC) curve analysis was used to assess the sensitivity and specificity of neutrophil-to-lymphocyte ratio (NLR), neutrophil-to-platelet ratio (NPR), and lymphocyte-to-platelet ratio (LPR) in the diagnosis of CIED infections, evaluate the spread of the infectious process in patients with PI and differentiate additional structures related to the presence of lead. Results: The values of NLR and NPR were significantly higher in infectious patients than non-infectious controls (3.07 vs. 2.59; p < 0.001, and 0.02 vs. 0.01; p = 0.008) and the area under the ROC curve (AUC) was 0.59; p < 0.001 and 0.56; p < 0.001, respectively. The high specificity of the new markers in detecting the infectious process was demonstrated: 72.82% for NLR (optimal cut-off value: 3.06) and 79.47% for NPR (optimal cut off value: 0.02). The values of NLR and NPR were significantly higher in patients with vegetations than in non-infectious patients with the presence of additional lead-related masses (3.37 vs. 2.61; p < 0.001 and 0.03 vs. 0.02; p = 0.008). The AUC of NLR and NPR for the prediction of vegetations was 0.65; p < 0.001 and 0.60; p < 0.001 with the highest specificity of NPR (82.78%) and an optimal cut-off value of 0.03. NLR and NPR were higher in patients with LRIE compared to isolated PI (4.11 vs. 2.56; p < 0.001 and 0.03 vs. 0.02; p < 0.001) and the ROC curve analysis for coexistence LRIE with PI showed the AUC for NLR: 0.57; p < 0.001 and AUC for NPR: 0.55; p = 0.001. High specificity in the detection of coexistence between PI and LRIE was demonstrated for NLR (87.33%), with an optimal cut-off value of 3.13. Conclusions: Novel hematological markers (NLR and NPR) are characterized by high specificity in the initial diagnosis of CIED infections, with optimal cut-off values of 3.06 and 0.02. NLR is also useful in the assessment of the spread of infection in patients with PI, with a calculated optimal cut-off value of 3.13. NPR may be helpful in the differentiation of vegetation and vegetation-like masses with an optimal cut-off value of 0.03.
Background: Patients with infectious complications related to the presence of cardiac implantable electronic devices (CIED) constitute a heterogeneous group, including local pocket infection (PI) and lead related infectious endocarditis (LRIE). The diagnosis of CIED-related infection is often difficult and requires complex imaging and microbiological tests. The aim of the current study was to evaluate the usefulness of new simple hematological parameters in detecting infectious complications in patients with CIED and assessing their extent. Methods: The retrospective analysis of clinical data of 2909 patients (36.37% with CIED-related infections), undergoing transvenous lead extraction (TLE) procedures in three high-volume centres in the years 2006-2020, was conducted. The sensitivity and specificity of new hematological markers were evaluated: the neutrophil to lymphocyte ratio (NLR), neutrophil to platelet ratio (NPR), and lymphocyte to platelet ratio (LPR) in the diagnosis of infectious complications, assessment of the spread of the infectious process and differentiation of additional structures related to the presence of leads. Results: In patients with CIED infections, compared to the non-infectious group, high inflammatory parameters were confirmed, and the highest specificity of the new markers in detecting the infectious process was demonstrated. (79.47% for NPR and 72.82% for NLR). Analysis of laboratory parameters in infectious and non-infectious patients with the presence of additional lead-related masses showed the highest specificity of NPR (82,78%) in predicting the diagnosis of vegetation. Comparison of laboratory parameters in patients with LRIE and PI showed higher NLR % (4.24 vs 2.56; p<0.001, area under curve (AUC) in a receiver operating characteristic (ROC) curve: 0.67 and 0.78 respectively) and higher NPR (0.03 vs 0.02; p<0.001; AUC: 0,51 and 0,55) in patients with LRIE. The highest sensitivity in the detection of coexistence LRIE with PI has been demonstrated for NLR (87.33%). Conclusions: Novel hematological markers may be helpful in the recognition of the inflammatory process in patients with CIED, differentiation of vegetation and vegetation-like masses, and the extent of infection in patients with PI.