An experimental study is conducted to examine the impact of internal geometry of a fluidic oscillator on its working mechanisms, i.e., the widths of the inlet wedge W1, mixing chamber W2, and exit throat W3, normalized by the width of the inlet throat W0. Using time-resolved particle image velocimetry, the flow dynamics both inside and outside the oscillator are measured simultaneously. The phase-averaged flow fields are obtained using proper orthogonal decomposition analysis based on which the pressure fields are computed. It is found that the external jet spreading angle and the oscillation frequency are proportional to the width of the inlet wedge up to W1/W0 = 2. This is because the inlet wedge controls the feedback flow and accordingly the recirculation bubble in the mixing chamber. At a critical lower value of W1/W0 = 0.8, there is no feedback flow with a stable external sweeping jet. The mixing chamber width W2/W0 controls the size of the recirculation bubble, which has a notable proportional control on the spreading angle. With a small mixing chamber of W2/W0 = 2.9, it is also found that the strong feedback flow can still produce a stable sweeping jet motion but with a small spreading angle. The exit throat width W3/W0 has non-monotonous control on the external jet spreading angle and the oscillation frequency. It is noteworthy that the jet can still produce a stable sweeping motion even with a large value of W3/W0 = 4.2, which can significantly reduce the blocking effect of the exit.
We develop a method for the prediction of flow fields based on local particle image velocimetry (PIV) measurement. High spatial resolution can be achieved by focusing PIV on local flow regions; however, it is difficult for standard dynamic mode decomposition (DMD) to predict the temporally resolved flow field based on limited information in sub-domain. In this regard, the local flow field is embedded using time-delay to augment the spatial dynamics. As such, both high temporally and spatially resolved flow fields can be faithfully obtained from local PIV measurement using the DMD method. Using fabricated patterns, we demonstrate that DMD with time-delay embedding can faithfully predict dynamic patterns over a long time interval, whereas the standard DMD can only match the ground truth briefly following initiation. Using PIV measurement of a wake flow and a highly dynamic sweeping jet flow, the DMD with time-delay embedding can increase the temporal resolution up to 100 times with a prediction error rate of approximately 8%. Compared with wake flow, where unsteady flow patterns are relatively weak, a sweeping jet flow demonstrates that the prediction performance is improved even more significantly using time-delay embedding compared with standard DMD when the flow is highly dynamic. For sweeping jet flow, the prediction error rate can drop from 56% using standard DMD to 8.3% by embedding a time-delay smaller than five steps, for a small cost of calculation time. In addition, the DMD with time-delay embedding shows robustness to small noise. For data with high noise whose signal-to-noise ratio is 15, the method has an error rate of less than 5%.
The spatiotemporal distributions of the coolant coverage behind the 777-shaped hole, sweeping jet (SJ), and compact SJ were quantified comprehensively. Nitrogen gas was selected as the coolant, and its blowing ratio (M) was set from M = 1.0 to 3.0. The fast pressure-sensitive paint technique was applied to measure the instantaneous, mean, and unsteady film cooling effectiveness of the three configurations, and these data are compared side-by-side with the 777-shaped hole. The measured velocity spectra demonstrated a close level of Strouhal number for the SJ (St = 1.6–1.7) and compact SJ (St = 1.5–1.6). Due to the dynamic nature, both the SJ and compact SJ exhibited a highly unstable cooling effectiveness over the surface. Their effectiveness values were found to be lower than the 777 hole at relatively low M, but the compact SJ surpassed it and showed the highest effectiveness (i.e., the best cooling performance) as M ≥ 2.0 due to the widest coolant spreading. Compared with the SJ, the effectiveness of the compact SJ was consistently higher, but its coherence of flow structure was reduced, as revealed by a proper orthogonal decomposition analysis. Further simulations vividly describe the flow structures and oscillating processes inside the sweeping actuators. The SJ with compact geometry exhibited a lower exit momentum and more uniform coolant coverage than the SJ, leading to augmented adiabatic effectiveness.
The super-temporal-resolution (STR) reconstruction of turbulent flows is an important data augmentation application for increasing the data reach in measurement techniques and understanding turbulence dynamics. This paper proposes a data assimilation (DA) strategy based on weak-constraint four-dimensional variation to conduct an STR reconstruction in a turbulent jet beyond the Nyquist limit from given low-sampling-rate observations. Highly resolved large-eddy simulation (LES) data are used to produce synthetic measurements, which are used as observations and for validation. A segregated assimilation procedure is realised to assimilate the initial condition, inflow boundary condition and model error separately. Different types of observational data are tested. The first type is down-sampled LES data containing many small-scale turbulence structures with or without synthetic noise. The DA results show that the temporal variation of the small-scale structures is well recovered even with noise in the observations. The spectra are resolved to a frequency approximately one order of magnitude higher than what can be captured within the Nyquist limit. The second type of observation is low-sampling-rate tomographic particle image velocimetry (tomo-PIV) data with or without the injection of small-scale structures. The modulation between the large-scale structures contained in the tomo-PIV fields and the small scales injected from the observations is improved. The resultant small scales in the STR reconstruction have the characteristics of authentic turbulence to a considerable extent. Additionally, DA yields much smaller errors in the prediction of particle positions when compared with the Wiener filter, demonstrating the great potential for Lagrangian particle tracking in measurement techniques.
In this paper, we present an innovative approach using physics-informed neural networks to reconstruct high-frequency, full-field flows, including the pressure field, by integrating sparse, noisy, low-temporal-resolution particle image velocimetry (PIV) data with high-temporal-resolution pressure probe data. This method effectively leverages the spatial richness of PIV data and the temporal abundance of pressure probe data, offering a complementary spatial and temporal data fusion. The incorporation of physical laws via equation constraints enables the neural network to accurately learn and predict complex fluid dynamics, achieving comprehensive flow field reconstructions. Rigorous testing across various flow types—periodic, non-periodic, and complex—against critical parameters like sampling interval (SI), number of grid points per snapshot (NGPIS), and number of pressure probes (NPP) has demonstrated remarkable accuracy. The results show reconstruction errors for velocity components (u, v) and pressure (p) below 5% with sufficient data, and around 10% for v and p, and below 5% for u in data-limited scenarios. A case study with SI = 30, NGPIS = 2000, NPP = 5 underscores the enhanced robustness and accuracy of random sampling, especially under various noisy conditions. Thus, this approach shows significant potential for temporal and spatial reconstruction of flow fields.