Xingsong Sun

Dr. Xingsong Sun

China Institute of Water Resources and Hydropower Research
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2023 in Construction and Building Materials
Verified
Journal Article
Closed access
XWXiaogang Wang
Xiaogang Wang
XSXingsong Sun
Xingsong Sun
YWYujie Wang
Yujie Wang
TYTao Yin
Tao Yin
XLXingchao Lin
Xingchao Lin

9 January 2021 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
TYTao Yin
Tao Yin
XSXingsong Sun
Xingsong Sun
YWYujie Wang
Yujie Wang
YZYufei Zhao
Yufei Zhao
SWShuangjing Wang
Shuangjing Wang
HCHongjie Chen
Hongjie Chen
The selection of corrosion test method in the corrosion study of the prestressed anchors is an important issue. In this paper, the corrosion test of anchors was conducted with electrolytic corrosion test method. The corrosion characteristics of the anchor cables were examined. The effects of sodium chloride solution concentration, current, test time, and prestress level on corrosion were studied. The applicability of electrolytic corrosion method in anchor cable corrosion study is discussed subsequently. The results show that the corrosion of the anchor appears to be uniform corrosion. With the corrosion of the anchor, the central wire of the cable was basically not corroded, and the cross‐sectional shape of the outer wire changes from a round to fan shape. The sodium chloride concentration and prestress level have no obvious effects on the corrosion of the anchor. The variation of test time does not affect the difference between the measured and theoretical calculated results, while a proper current in the electrolysis test may help reduce the difference. The measured corrosion rate fluctuates from −4% to 10% and tends to be higher compared with calculated results based on Faraday’s law. The study indicates that the electrolytic corrosion test is applicable in the anchor corrosion study.

22 February 2022 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
TYTao Yin
Tao Yin
XSXingsong Sun
Xingsong Sun
YWYujie Wang
Yujie Wang
YZYufei Zhao
Yufei Zhao
With the wide application of prestressed anchors in high slopes, underground structures, and bridge projects, the corrosion problems of the anchor structure during the long-term service have demanded more attention. Because of the environmental impact and structural characteristics, anchor cable corrosion is almost inevitable. To obtain the corrosion status of the anchors that have served over 10 years in the underground chambers of a power station, a field investigation was performed. The environment aggressivity was evaluated, and the anchor corrosion was inspected during the investigation. The results show that the effect of groundwater and stray current on anchor corrosion is slight. The main cause of the severe corrosion of the anchor heads is the high temperature and humidity in the chamber. To better evaluate the corrosion tendency and corrosion degree of the anchor head, a corrosion rating method was proposed based on the principles of existing investigation methods and the actual corrosion situation of anchors observed on-site. It was proved that the rating method can effectively reflect the corrosion characteristics and determine the areas prone to corrosion. This field investigation suggests that a regularly scheduled investigation is of great significance and meaning for accurately obtaining the corrosion status, assessing the failure risk, and issuing an early warning.

29 May 2026 in Construction and Building Materials
Verified
Journal Article
Closed access
MSMing Shi
Ming Shi
YWYujie Wang
Yujie Wang
XSXingsong Sun
Xingsong Sun

1 June 2026 in Symmetry
Verified
Journal Article
Open access
PDF file
TYTao Yin
Tao Yin
YWYujie Wang
Yujie Wang
LLLipeng Liu
Lipeng Liu
YQYong Qiu
Yong Qiu
MSMing Shi
Ming Shi
XSXingsong Sun
Xingsong Sun
As an active reinforcement technology, prestressed anchor cables are susceptible to environmental corrosion during long-term service. Corrosion occurs and progresses more rapidly, especially in an alternating wet–dry environment, which can degrade the mechanical properties of prestressed anchor cables and may ultimately lead to failure. Current methods typically evaluate the mechanical properties of anchor cables based on cross-sectional loss calculated from the average weight loss ratio. However, this uniform-corrosion assumption may underestimate the effect of corrosion on mechanical performance. In this study, a testing apparatus for corroding prestressed anchor cables under alternating wet–dry conditions was developed. The apparatus enabled accurate loading and nondestructive sampling. Using this apparatus, alternating wet–dry corrosion tests and mechanical tensile tests were conducted on anchor cables under different stress levels. The relationship between weight loss ratio and mechanical properties was then analyzed. Based on this relationship, an equation was derived to calculate the breaking strength of corroded anchor cables in alternating wet–dry environments. The service life estimated using this equation was closer to that observed in actual anchor cable failure cases. This indicates that the proposed equation provides more accurate predictions than methods based on the uniform-corrosion assumption.

1 October 2021 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
XSXingsong Sun
Xingsong Sun
YWY J Wang
Y J Wang
TYT Yin
T Yin
HCH J Chen
H J Chen
YZY F Zhao
Y F Zhao
LLL P Liu
L P Liu
In this study, the characteristics of corrosion were described on the basis of previous findings on the corrosion of rock anchors, and various factors causing corrosion were explored. A corrosion investigation system of rock anchors was established by summarizing various methods for the detection of corrosion and influencing factors. In this system, corrosion was investigated by detecting and assessing the environmental influencing factors, analyzing the corrosion rate and morphological characteristics, testing the anchoring structure, and evaluating the causes, development, and prediction of corrosion. On-site corrosion cases were also examined. Results verified that this system is reasonable, effective, and practical.