Wei DU

Ms. Wei DU

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2022 in Molecules
Verified
Journal Article
Open access
PDF file
WDWei DU
Wei DU
HFHong-Min Fan
Hong-Min Fan
YZYuxin ZHANG
Yuxin ZHANG
XJXiao Hua Jiang
Xiao Hua Jiang
YLYun Li
Yun Li
Background: Excessive oxidative stress is associated with hypertension in professional high-temperature working conditions. Polyphenols exhibit a cardioprotective effect. Hawthorn contains high amounts of flavonoids, though its effect on hypertension protection has yet to be studied. This study aims to investigate this effect of extract of hawthorn (EH) or its combination with vitamin C (Vit. C) in rats induced by working under a hot environment. Methods: Forty-two male rats were randomly divided into a control group under normal temperature and six treatment groups exposed at 33 ± 1 °C along with 1 h of daily treadmill running. They were orally provided with water, Vit. C (14mg/kg), EH (125, 250, and 500 mg/kg), and EH500 + Vit. C, once a day for four weeks. Results: Both EH and Vit. C alone reduced the systolic and diastolic blood pressure of rats exposed to the heat environment; however, their joint supplementation completely maintained their blood pressure to the normal level throughout the experimental period. No morphological changes were found on the intima of aorta. Moreover, the co-supplementation of EH and Vit. C prevented the changes of heat exposure in inducing oxidative stress markers, such as glutathione peroxidase, catalase, total antioxidant capacity, and nitric oxide; the synergistic action was more effective than either individual treatment of EH and Vit. C. Furthermore, the administration of EH had more potent effects on increasing superoxide dismutase, IL-2, the 70 kilodalton heat shock proteins and high sensitivity C reactive protein, and decreasing serum malondialdehyde and lipofuscin in vascular tissue than those in Vit. C group. Conclusions: A strong synergistic effect of EH and Vit. C on the prevention of hypertension under heat exposure was established, as they inhibited the oxidative stress state. This study also sets up a novel intervention strategy in animal models for investigation on the early phases of hypertension induced by heat exposure.

1 May 2018 in European Journal of Anaesthesiology
Verified
Journal Article
Closed access
PDF file
BSBan Leong Sng
Ban Leong Sng
WDWei DU
Wei DU
MLMan Xin Lee
Man Xin Lee
FIFarida Ithnin
Farida Ithnin
DMDeepak Mathur
Deepak Mathur
ASAlex Sia
Alex Sia
Hypotension is a common side effect of spinal anaesthesia during caesarean delivery and is associated with maternal and foetal adverse effects. We developed an updated double intravenous vasopressor automated (DIVA) system that administers phenylephrine or ephedrine based on continuous noninvasive haemodynamic monitoring using the Nexfin device. The aim of our present study is to compare the performance and reliability of the DIVA system against Manual Vasopressor Bolus administration. A randomised, double-blind controlled trial. Single-centre, KK Women's and Children's Hospital, Singapore. Two hundred and thirty-six healthy women undergoing elective caesarean delivery under spinal anaesthesia. The primary outcome was the incidence of maternal hypotension. The secondary outcome measures were reactive hypertension, total vasopressor requirement and maternal and neonatal outcomes. The DIVA group had a significantly lower incidence of maternal hypotension, with 39.3% (46 of 117) patients having any SBP reading less than 80% of baseline compared with 57.5% (65 of 113) in the manual vasopressor bolus group (P = 0.008). The DIVA group also had fewer hypotensive episodes than the manual vasopressor bolus group (4.67 versus 7.77%; P < 0.0001). There was no difference in the incidence of reactive hypertension or the total vasopressor requirement. The DIVA group had less wobble in system performance. Maternal and neonatal outcomes were similar. The DIVA system achieved better control of maternal blood pressure after spinal anaesthesia than manual vasopressor bolus administration. Clinicaltrials.gov identifier: NCT02277730.