Ivan Pavić

Dr. Ivan Pavić

Electrical Engineering, University of Split, Faculty of Maritime Studies, Split, Splitsko-Dalmatinska Županija, Croatia
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Pedagogika-Pedagogy
Verified
Journal Article
Closed access
HJHrvoje Jaram
Hrvoje Jaram
USUniversity of Split
University of Split
PVPero Vidan
Pero Vidan
SVSrđan Vukša
Srđan Vukša
IPIvan Pavić
Ivan Pavić

12 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MZMarko Zubcic
Marko Zubcic
IPIvan Pavić
Ivan Pavić
Petar MatićPetar Matić
Petar Matić
APAdam Polak
Adam Polak
This paper investigates the detection of broken rotor bar in squirrel cage induction motors using a novel approach of randomly positioning a triaxial sensor over the motor surface. This study is conducted on two motors under laboratory conditions, where one motor is kept in a healthy state, and the other is subjected to a broken rotor bar (BRB) fault. The induced electromotive force of the triaxial coils, recorded over ten days with 100 measurements per day, is statistically analyzed. Normality tests and graphical interpretation methods are used to evaluate the data distribution. Parametric and non-parametric approaches are used to analyze the data. Both approaches show that the measurement method is valid and consistent over time and statistically distinguishes healthy motors from those with BRB defects when a reference or threshold value is specified. While the comparison between healthy motors shows a discrepancy, the quantitative analysis shows a smaller estimated difference in mean values between healthy motors than comparing healthy and BRB motors.

28 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
IPIvan Pavić
Ivan Pavić
JŠJoško Šoda
Joško Šoda
VGVlatko Gašparić
Vlatko Gašparić
MIMile Ivanda
Mile Ivanda
Raman and photoluminescence (PL) spectroscopy are important analytic tools in materials science that yield information on molecules’ and crystals’ vibrational and electronic properties. Here, we show results of a novel approach for Raman and PL spectroscopy to exploit variable spectral resolution by using zoom optics in a monochromator in the front of the detector. Our results show that the spectral intervals of interest can be recorded with different zoom factors, significantly reducing the acquisition time and changing the spectral resolution for different zoom factors. The smallest spectral intervals recorded at the maximum zoom factor yield higher spectral resolution suitable for Raman spectra. In contrast, larger spectral intervals recorded at the minimum zoom factor yield the lowest spectral resolution suitable for luminescence spectra. We have demonstrated the change in spectral resolution by zoom objective with a zoom factor of 6, but the perspective of such an approach is up to a zoom factor of 20. We have compared such an approach on the prototype Raman spectrometer with the high quality commercial one. The comparison was made on ZrO2 and TiO2 nanocrystals for Raman scattering and Al2O3 for PL emission recording. Beside demonstrating that Raman spectrometer can be used for PL and Raman spectroscopy without changing of grating, our results show that such a spectrometer could be an efficient and fast tool in searching for Raman and PL bands of unknown materials and, thereafter, spectral recording of the spectral interval of interest at an appropriate spectral resolution.

15 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
AAArkadiusz Adamczyk
Arkadiusz Adamczyk
MKMaciej Klebba
Maciej Klebba
MWMariusz Wąż
Mariusz Wąż
IPIvan Pavić
Ivan Pavić
This study explores the design and performance of an underwater magnetic sensor network (UMSN) tailored for intrusion detection in complex environments such as riverbeds and areas with dense vegetation. The system utilizes wireless sensor network (WSN) principles and integrates AMR-based magnetic sensors (e.g., LSM303AGR) with MEMS-based accelerometers to provide accurate and high-resolution magnetic field measurements. Extensive calibration techniques were employed to correct hard-iron and soft-iron distortions, ensuring reliable performance in fluctuating environmental conditions. Field tests included both controlled setups and real-world scenarios, such as detecting intrusions across river sections, shorelines, and coordinated land-water activities. The results showed detection rates consistently above 90%, with response times averaging 2.5 s and a maximum detection range of 5 m. The system also performed well under adverse weather conditions, including fog and rain, demonstrating its adaptability. The findings underline the potential of UMSN as a scalable and cost-efficient solution for monitoring sensitive areas. By addressing the limitations of traditional surveillance systems, this research offers a practical framework for enhancing security in critical regions, laying the groundwork for future developments in magnetic sensor technology.

1 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
IPIvan Pavić
Ivan Pavić
NKNediljko Kaštelan
Nediljko Kaštelan
AAArkadiusz Adamczyk
Arkadiusz Adamczyk
MIMile Ivanda
Mile Ivanda
Raman spectroscopy is a powerful analytical technique based on the inelastic scattering of photons. Conventional macro-Raman spectrometers are suitable for mass analysis but often lack the spatial resolution required to accurately examine microscopic regions of interest. For this reason, the development of micro-Raman spectrometers has been driven forward. However, even with micro-Raman spectrometers, high resolution is required to gain better insight into materials that provide low-intensity Raman signals. Here, we show the development of a micro-Raman spectrometer with implemented zoom lens technology. We found that by replacing a second collimating mirror in the monochromator with a zoom lens, the spectral resolution could be continuously adjusted at different zoom factors, i.e., high resolution was achieved at a higher zoom factor and lower spectral resolution was achieved at a lower zoom factor. A quantitative analysis of a micro-Raman spectrometer was performed and the spectral resolution was analysed by FWHM using the Gaussian fit. Validation was also performed by comparing the results obtained with those of a high-grade laboratory Raman spectrometer. A quantitative analysis was also performed using the ANOVA method and by assessing the signal-to-noise ratio between the two systems.