We present a comparative study of ionizing radiation effects in 0.18 and 0.25 /spl mu/m CMOS transistors, with the goal of evaluating the impact of device scaling in the design of low-noise rad-hard analog circuits. Device parameters were monitored before and after irradiation with 10 keV X-rays and /sup 60/Co /spl gamma/-rays and after subsequent annealing. The effects of different biasing conditions during irradiation and annealing are discussed. The results are used to point out the different radiation hardness properties of the examined technologies, belonging to different CMOS generations.
Among movement disorders, essential tremor is by far the most common, as much as eight times more prevalent than Parkinson’s disease. Although these two conditions differ in their presentation and course, clinicians do not always recognize them, leading to common misdiagnoses. Proper and early diagnosis is important for receiving the right treatment and support. In this paper, the development of a portable and reliable tremor classification system based on a wearable device, enabling clinicians to differentiate between essential tremor and Parkinson’s disease-associated one, is reported. Inertial data were collected from subjects with a well-established diagnosis of tremor, and analyzed to extract different sets of relevant spectral features. Supervised learning methods were then applied to build several classification models, among which the best ones achieved an average accuracy above 90%. Results encourage the use of wearable technology as effective and affordable tools to support clinicians.
26 June 2006 in IEEE Transactions on Nuclear Science
This paper presents a study of the ionizing radiation tolerance of 0.13 /spl mu/m CMOS transistors, in view of the application to the design of rad-hard analog integrated circuits. Static, signal and noise parameters of the devices were monitored before and after irradiation with /sup 60/Co /spl gamma/-rays at a 10 Mrad total ionizing dose. The effects on key parameters such as threshold voltage shift and 1/f noise are studied and compared with the behavior under irradiation of devices in previous CMOS generations.
In this paper, a wearable electronic platform for in-ear photoplethysmography is presented. The system is specifically designed with a miniaturized form factor in order to enable the potential monitoring of athletes during physical activity, as well as professionals wearing earbuds or headphones during their normal duties. Measurements have been collected to address the main factors affecting the signal quality. As a result, the fine tuning of the configuration parameters allowed the extension of the battery lifetime of the system to over 3 days of continuous operation. Moreover, an investigation of the best body measurement location has been carried out. Two different algorithms have been developed: the former is a lightweight procedure for heart rate (HR) estimation suitable for embedded implementation whereas the latter features a motion mitigation adaptive filter to compensate the effect of motion artifacts (MAs).
12 December 2007 in IEEE Transactions on Nuclear Science
Degradation mechanisms associated to lateral isolation oxides are discussed to account for total ionizing dose effects on the noise performance of 90 nm and 130 nm CMOS devices and for their dependence on geometry and operating conditions. In NMOSFETs with a conventional open layout, after irradiation the parasitic transistor at the device edges turns on and contributes to the total device noise. The paper provides a model to help understanding the impact of this radiation-induced noise contribution on white and 1/f noise terms. The different behavior of NMOSFETs in the two examined technology nodes is analyzed in this framework, and design criteria to reduce noise degradation in irradiated devices are discussed.