Patrick Locatelli

Dr. Patrick Locatelli

University of Bergamo
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2020 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
APAshley Marie Polhemus
Ashley Marie Polhemus
JNJan M. Novák
Jan M. Novák
JFJose Ferrao
Jose Ferrao
SSSara Simblett
Sara Simblett
MRMarta Radaelli
Marta Radaelli
MHMatthew Hotopf
Matthew Hotopf
Background: Despite the increasing use of remote measurement technologies (RMT) such as wearables or biosensors in health care programs, challenges associated with selecting and implementing these technologies persist. Many health care programs that use RMT rely on commercially available, “off-the-shelf” devices to collect patient data. However, validation of these devices is sparse, the technology landscape is constantly changing, relative benefits between device options are often unclear, and research on patient and health care provider preferences is often lacking. Objective: To address these common challenges, we propose a novel device selection framework extrapolated from human-centered design principles, which are commonly used in de novo digital health product design. We then present a case study in which we used the framework to identify, test, select, and implement off-the-shelf devices for the Remote Assessment of Disease and Relapse-Central Nervous System (RADAR-CNS) consortium, a research program using RMT to study central nervous system disease progression. Methods: The RADAR-CNS device selection framework describes a human-centered approach to device selection for mobile health programs. The framework guides study designers through stakeholder engagement, technology landscaping, rapid proof of concept testing, and creative problem solving to develop device selection criteria and a robust implementation strategy. It also describes a method for considering compromises when tensions between stakeholder needs occur. Results: The framework successfully guided device selection for the RADAR-CNS study on relapse in multiple sclerosis. In the initial stage, we engaged a multidisciplinary team of patients, health care professionals, researchers, and technologists to identify our primary device-related goals. We desired regular home-based measurements of gait, balance, fatigue, heart rate, and sleep over the course of the study. However, devices and measurement methods had to be user friendly, secure, and able to produce high quality data. In the second stage, we iteratively refined our strategy and selected devices based on technological and regulatory constraints, user feedback, and research goals. At several points, we used this method to devise compromises that addressed conflicting stakeholder needs. We then implemented a feedback mechanism into the study to gather lessons about devices to improve future versions of the RADAR-CNS program. Conclusions: The RADAR device selection framework provides a structured yet flexible approach to device selection for health care programs and can be used to systematically approach complex decisions that require teams to consider patient experiences alongside scientific priorities and logistical, technical, or regulatory constraints.

15 October 2020 in Electronics
Verified
Journal Article
Open access
PDF file
Patrick LocatelliPatrick Locatelli
Patrick Locatelli
DADario Alimonti
Dario Alimonti
Gianluca TraversiGianluca Traversi
Gianluca Traversi
Valerio ReValerio Re
Valerio Re
Among movement disorders, essential tremor is by far the most common, as much as eight times more prevalent than Parkinson’s disease. Although these two conditions differ in their presentation and course, clinicians do not always recognize them, leading to common misdiagnoses. Proper and early diagnosis is important for receiving the right treatment and support. In this paper, the development of a portable and reliable tremor classification system based on a wearable device, enabling clinicians to differentiate between essential tremor and Parkinson’s disease-associated one, is reported. Inertial data were collected from subjects with a well-established diagnosis of tremor, and analyzed to extract different sets of relevant spectral features. Supervised learning methods were then applied to build several classification models, among which the best ones achieved an average accuracy above 90%. Results encourage the use of wearable technology as effective and affordable tools to support clinicians.

1 June 2014
Verified
Conference Paper
Closed access
MCMichele Caldara
Michele Caldara
DCDaniele Comotti
Daniele Comotti
MGMichael Galizzi
Michael Galizzi
Patrick LocatelliPatrick Locatelli
Patrick Locatelli
Valerio ReValerio Re
Valerio Re
MRMaria Cristina Rizzetti
Maria Cristina Rizzetti
A miniaturized wireless Attitude and Heading Reference System has been developed with the primary purpose to achieve a body sensor network for motor performance quantitative analysis of Parkinson's disease patients during rehabilitation sessions. The paper describes the performance of the single node, the peculiarities of the developed wearable network and the custom software developed specifically for the Extended Timed-Up-and-Go test. An experimental protocol on Parkinson's Disease patients is currently ongoing. This paper reports the preliminary results, involving 13 patients (mean age 64.6±9) with a moderate disease level and 4 controls (mean age 64.3±4). The data taken during rehabilitation exercise have been analyzed and outcomes are discussed.

1 June 2017
Verified
Conference Paper
Closed access
Patrick LocatelliPatrick Locatelli
Patrick Locatelli
DADario Alimonti
Dario Alimonti
Essential tremor is the most common form of tremors presenting an outpatient neurology practice and yet it may be often difficult to differentiate with tremors in Parkinson's disease - one of the commonest neurodegenerative disease. Since using appropriate medication is fundamental for efficacy and avoiding serious side effects, precise diagnoses are recommended. Single photon emission computerized tomography (SPECT) of the dopamine transporter (DAT) is a sensitive and specific imaging tool, but expensive and not advisable as screening means. Wearable devices are developing such effective and affordable supports for clinicians. This work aims to be a pilot study of future tremor classification. A low-cost miniaturized wearable device was exploited to collect movements of subject's hand during resting, postural and kinetic tasks. Data were analyzed to extract parameters describing tremors frequency distribution. Results confirm that PD and ET are well separated in the frequency domain, laying the basis for accurate classification.

1 December 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SSSara Siddi
Sara Siddi
IGIago Giné-Vázquez
Iago Giné-Vázquez
Raquel BailónRaquel Bailón
Raquel Bailón
FMFaith Matcham
Faith Matcham
FLFemke Lamers
Femke Lamers
OCon behalf of the RADAR-CNS Consortium
on behalf of the RADAR-CNS Consortium
Background: Changes in lifestyle, finances and work status during COVID-19 lockdowns may have led to biopsychosocial changes in people with pre-existing vulnerabilities such as Major Depressive Disorders (MDDs) and Multiple Sclerosis (MS). Methods: Data were collected as a part of the RADAR-CNS (Remote Assessment of Disease and Relapse—Central Nervous System) program. We analyzed the following data from long-term participants in a decentralized multinational study: symptoms of depression, heart rate (HR) during the day and night; social activity; sedentary state, steps and physical activity of varying intensity. Linear mixed-effects regression analyses with repeated measures were fitted to assess the changes among three time periods (pre, during and post-lockdown) across the groups, adjusting for depression severity before the pandemic and gender. Results: Participants with MDDs (N = 255) and MS (N = 214) were included in the analyses. Overall, depressive symptoms remained stable across the three periods in both groups. A lower mean HR and HR variation were observed between pre and during lockdown during the day for MDDs and during the night for MS. HR variation during rest periods also decreased between pre- and post-lockdown in both clinical conditions. We observed a reduction in physical activity for MDDs and MS upon the introduction of lockdowns. The group with MDDs exhibited a net increase in social interaction via social network apps over the three periods. Conclusions: Behavioral responses to the lockdown measured by social activity, physical activity and HR may reflect changes in stress in people with MDDs and MS. Remote technology monitoring might promptly activate an early warning of physical and social alterations in these stressful situations. Future studies must explore how stress does or does not impact depression severity.

1 June 2015
Verified
Conference Paper
Closed access
MCM. Caldara
M. Caldara
Patrick LocatelliPatrick Locatelli
Patrick Locatelli
DCD. Comotti
D. Comotti
MGM. Galizzi
M. Galizzi
Valerio ReValerio Re
Valerio Re
MPM. Pessione
M. Pessione
In developed countries, sedentary lifestyle is a major health risk factor. In elderly people, such mobility limitation is worsened by the reduced self-confidence and the fear of falling, leading to a further motor deterioration. This work presents an application of a wireless Body Sensor Network as a simple and easy-to-use individual motor function assessment tool for elderly. The wearable nodes have been exploited to monitor the body during the Six-Minute Walk Test and a set of stability tests. During the exercises, wearable sensors inertial data, along with the real-time orientation of the platforms, have been exploited to obtain gold-standard indicators (such as total distance) and some additional gait parameters. Stability tests consist of a series of single and double stance exercises aimed to assess the balance of the subject. This paper presents the system, the processing and the preliminary results on two subjects groups of different ages (31±6 and 70.8±7).