Approximately $$1/2500$$ babies are born with only one functioning ventricle and the Fontan is the third and, ideally final staged palliative operation for these patients. This altered circulation is prone to failure with survival rates below $$50\%$$ into adulthood. Chronically elevated inferior vena cava (IVC) pressure is implicated as one cause of the mortality and morbidity in this population. An injection jet shunt (IJS) drawing blood-flow directly from the aortic arch to significantly lower IVC pressure is proposed. A computer-generated 3D model of a 2–4 year old patient with a fenestrated Fontan and a cardiac output of 2.3 L/min was generated. The detailed 3D pulsatile hemodynamics are resolved in a zero-dimensional lumped parameter network tightly-coupled to a 3D computational fluid dynamics model accounting for non-Newtonian blood rheology and resolving turbulence using large eddy simulation. IVC pressure and systemic oxygen saturation were tracked for various IJS-assisted Fontan configurations, altering design parameters such as shunt and fenestration diameters and locations. A baseline “failing” Fontan with a 4 mm fenestration was tuned to have an elevated IVC pressure (+ 17.8 mmHg). Enlargement of the fenestration to 8 mm resulted in a 3 mmHg IVC pressure drop but an unacceptable reduction in systemic oxygen saturation below 80%. Addition of an IJS with a 2 mm nozzle and minor volume load to the ventricle improved the IVC pressure drop to 3.2 mmHg while increasing systemic oxygen saturation above 80%. The salutary effects of the IJS to effectively lower IVC pressure while retaining acceptable levels of oxygen saturation are successfully demonstrated.
6 May 2021 in Journal of Biomechanical Engineering
This study investigates the hypothesis that by surgically manipulating the outflow graft (OG) implantation during ventricle assist device placement, it may be possible to reduce the risk of cerebral embolism. We investigate this hypothesis using a computational approach on a patient-specific basis under fully pulsatile hemodynamics with a multiscale computational fluid dynamics model incorporating a coupled Eulerian-Lagrangian scheme that effectively tracks emboli in the fluid domain. Blood is modeled as a non-Newtonian fluid based on the hematocrit level. Preliminary flow analysis shows that depending on the anastomosis angle the left ventricular assist device (LVAD) can enhance the flow to the cerebral circulation by nearly 31%. Z-test results suggest that unsteady-flow modeling ought to be an integral part of any cardiovascular simulation with residual ventricular function. Assuming unsteady-flow conditions, a shallow LVAD outflow graft anastomosis angle is the most optimal if thrombi are released from the aortic-root reducing cerebral embolization incidence to 15.5% and from the ventricle to 17%, while a more pronounced anastomosis angle becomes advantageous when particles originate from the LVAD with an embolization rate of 16.9%. Overall, computations suggest that a pronounced LVAD anastomosis angle is the better implementation. Unsteady modeling is shown to be necessary for the presence of significant antegrade aortic-root flow which induces cyclical flow patterns due to residual pulsatility. On the other hand, depending on thrombus origin and ventricular assist devices (VAD) anastomosis angle there is a strong tradeoff in embolization rates.
Around 8% of all newborns with a Congenital Heart Defect (CHD) have only a single functioning ventricle. The Fontan operation has served as palliation for this anomaly for decades, but the surgery entails multiple complications, and the survival rate is less than 50% by adulthood. A rapidly testable novel alternative is proposed by creating a bifurcating graft, or Injection Jet Shunt (IJS), used to “entrain” the pulmonary flow and thus provide assistance while reducing the caval pressure. A dynamically scaled Mock Flow Loop (MFL) has been configured to validate this hypothesis. Three IJS nozzles of varying diameters 2, 3, and 4 mm with three aortic anastomosis angles and pulmonary vascular resistance (PVR) reduction have been tested to validate the hypothesis and optimize the caval pressure reduction. The MFL is based on a Lumped-Parameter Model (LPM) of a non-fenestrated Fontan circulation. The best outcome was achieved with the experimental testing of a 3 mm IJS by producing an average caval pressure reduction of more than 5 mmHg while maintaining the clinically acceptable pulmonary flow rate (Qp) to systemic flow rate (Qs) ratio of ~1.5. Furthermore, alteration of the PVR helped in achieving higher caval pressure reduction with the 3 mm IJS at the expense of an increase in Qp/Qs ratio.
The impact of different meditation protocols on human health is explored at the cognitive and cellular levels. Preksha Dhyana meditation has been observed to seemingly affect the cognitive performance, transcriptome, and methylome of healthy and novice participant practitioners. In this study, we performed correlation analyses to investigate the presence of any relationships in the changes in cognitive performance and DNA methylation in a group of college students practicing Preksha Dhyāna (N = 34). Nine factors of cognitive performance were assessed at baseline and 8 weeks postintervention timepoints in the participants. Statistically significant improvements were observed in six of the nine assessments, which were predominantly relating to memory and affect. Using Illumina 850 K microarray technology, 470 differentially methylated sites (DMS) were identified between the two timepoints (baseline and 8 weeks), using a threshold of p-value < 0.05 and methylation levels beyond −3% to 3% at every site. Correlation analysis between the changes in performance on each of the nine assessments and every DMS unveiled statistically significant positive and negative relationships at several of these sites. The identified DMS were in proximity of essential genes involved in signaling and other important metabolic processes. Interestingly, we identified a set of sites that can be considered as biomarkers for Preksha meditation improvements at the genome level.
23 November 2021 in Computer Methods in Biomechanics and Biomedical Engineering
We investigate tailoring cannula implantation angles of left ventricle assist devices (LVAD) to reduce cerebral embolism risk for full LVAD support. We resolve pulsatile hemodynamics with a multi-scale computational fluid dynamics model coupled to a Lagrangian scheme tracking 2-5 mm particles for three cannula implantations. Blood is modeled as non-Newtonian. Cerebral flow distribution is altered depending on anastomosis angle and comparison of means embolization rates between steady and unsteady flow models show that unsteady modeling is more accurate even in the full LVAD support case. Intermediate angle implantation yields lowest cerebral embolization incidence of 11% vs 29% for normal and 36% for shallow implantation.
Rationale: Approximately 1/2500 babies are born with only one functioning ventricle and the Fontan is the third and, ideally final staged palliative operation for these patients. This altered circulation is prone to failure with survival rates below 50% into adulthood in some series. Chronically elevated inferior vena cava (IVC) pressure is implicated as one cause of the mortality and morbidity in this population.Objective: An injection jet shunt (IJS) drawing blood-flow directly from the aortic arch to significantly lower IVC pressure is proposed.Methods and Results: A computer-generated 3D model of a 2–4 year old patient with a fenestrated Fontan and a cardiac output of 2.3L/min was generated. The detailed 3D pulsatile hemodynamics are resolved in a zero-dimensional lumped parameter network tightly-coupled to a 3D computational fluid dynamics model accounting for non-Newtonian blood rheology and resolving turbulence using large eddy simulation. IVC pressure and systemic oxygen saturation were tracked for various IJS-assisted Fontan configurations, altering design parameters such as shunt and fenestration diameters and locations.A baseline “failing” Fontan with 4mm fenestration was tuned to elevated IVC pressure (\(+17.8mmHg\)). Enlargement of the fenestration to 8mm resulted in a 3mmHg IVC pressure drop but an unacceptable reduction in systemic oxygen saturation below 80%. Addition of an IJS with a 2mm nozzle and minor volume load to the ventricle improved the IVC pressure drop to 3.2mmHg while increasing systemic oxygen saturation above 80%.Conclusions: The salutary effects of the IJS to effectively lower IVC pressure while retaining acceptable levels of oxygen saturation are successfully demonstrated.