Alain Kassab

Prof. Dr. Alain Kassab

Department of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, FL 32816, USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
AOAndres F. Osorio
Andres F. Osorio
RORuben Osorio
Ruben Osorio
ACAndres Ceballos
Andres Ceballos
RTReginald Tran
Reginald Tran
WCWilliam Clark
William Clark
WDWilliam M. DeCampli
William M. DeCampli
Background. Currently, mechanical support is the most promising alternative to cardiac transplantation. Ventricular assist devices (VADs) were originally used to provide mechanical circulatory support in patients awaiting planned heart transplantation (‘bridge-to-transplantation’ therapy). The success of short-term bridge devices led to clinical trials evaluating the clinical suitability of long-term support (‘destination’ therapy) with left ventricular assist devices (LVADs). The first larger scale, randomised trial that tested long-term support with an LVAD reported a 44% reduction in the risk of stroke or death in patients with an LVAD. In spite of the success of LVADs as bridge-to-transplantation and long-term support, patients managed by these devices are still at risk of several adverse events. The most devastating complication is caused by embolisation of thrombi formed within the LVAD or inside the heart into the brain. Prevention of thrombi formation is attempted through anticoagulation management and by improving LVADs design; however, there is still significant occurrence of thromboembolic events in patients. Investigators have reported that the incidence of thromboembolic cerebral events ranges from 14% to 47% over a period of 6–12 months. Methods and approach. An alternative method to reduce the incidence of cerebral embolisation is proposed by the co-authors, and the hypothesis is that it is possible to minimise the number of thrombi flowing into the carotid and vertebral arteries by an optimal placement of the LVAD outflow conduit, with or without the addition of aortic bypass connecting the ascending aorta and the innominate artery (IA), or left carotid artery. This paper presents the computational fluid dynamics (CFD) analysis of the aortic arch haemodynamics using a representative geometry of the human aortic arch with or without an alternative aortic bypass. In order to study the trajectory of the thrombi within the aortic arch bed, the CFD code, Fluent 6.3, is utilised to resolve the flow field and to solve the Lagrangian particle tracking of thrombi released randomly at the inlet of the LVAD cannula. Results. Results are presented for simulations of thrombi in the range of 2–5 mm. The percentage of individual diameter as well as aggregate diameter thrombi flowing to the carotid and vertebral arteries as a function of LVAD conduit placement and aortic bypass implantation is reported. The influence of the LVAD conduit implantation and bypass reveals a nearly 50% variation in predicted cerebral embolism rates. Conclusions. The adjustment of the location of the anastomosis of the LVAD outflow cannula as well as its angle of incidence plays a significant role in the level of thromboembolisms. By proper adjustment in this CFD study of a synthetic model of an aortic arch bed, we found that nearly a 50% reduction in cerebral embolism could be achieved for a configuration consisting of a shallow angle of implantation over a baseline normal incidence of the LVAD cannula. Within the limitations of our model, we have established that the LVAD implantation geometry is an important factor and should be taken into consideration when implanting an LVAD. It is possible that other parameters such as distance of the LVAD outflow cannula to the root of the IA could affect the thrombi embolisation probabilities. However, the results of this study suggest that the risk of stroke may be significantly reduced by as much as 50% by tailoring the VAD implantation by a simple surgical manoeuvre. The results of this line of research may ultimately lead to techniques that can be used to estimate the optimal LVAD configuration in a patient-specific manner by pre-operative imaging.

1 July 2015 in Journal of Biomechanics
Verified
Journal Article
Closed access
Victor HuayamaveVictor Huayamave
Victor Huayamave
CRChristopher Rose
Christopher Rose
SSSheila Serra
Sheila Serra
BJBrendan Jones
Brendan Jones
EDEduardo Divo
Eduardo Divo
CPCharles T. Price
Charles T. Price

16 May 2014 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
IAI. Ricardo Argueta-Morales
I. Ricardo Argueta-Morales
RTReginald Tran
Reginald Tran
ACAndres Ceballos
Andres Ceballos
WCWilliam Clark
William Clark
RORuben Osorio
Ruben Osorio
WDWilliam M. DeCampli
William M. DeCampli
Stroke is the most devastating complication after ventricular assist device (VAD) implantation, with an incidence of 14%–47% despite improvements in device design and anticoagulation. This complication continues to limit the widespread implementation of VAD therapy. Patient-specific computational fluid dynamics (CFD) analysis may elucidate ways to reduce this risk. A patient-specific three-dimensional model of the aortic arch was generated from computed tomography. A 12 mm VAD outflow-graft (VAD-OG) “anastomosed” to the aorta was rendered. CFD was applied to study blood flow patterns. Particle tracks, originating from the VAD, were computed with a Lagrangian phase model and percentage of particles entering the cerebral vessels was calculated. Twelve implantation configurations of the VAD-OG and three particle sizes (2, 4, and 5 mm) were considered. Percentage of particles entering the cerebral vessels ranged from 6% for the descending aorta VAD-OG anastomosis, to 14% for the ascending aorta at 90 deg VAD-OG anastomosis. Values were significantly different among all configurations (X2 = 3925, p < 0.0001). Shallower and more cephalad anastomoses prevented formation of zones of recirculation in the ascending aorta. In this computational model and within the range of anatomic parameters considered, the percentage of particles entering the cerebral vessels from a VAD-OG is reduced by nearly 60% by optimizing outflow-graft configuration. Ascending aorta recirculation zones, which may be thrombogenic, can also be eliminated. CFD methods coupled with patient-specific anatomy may aid in identifying the optimal location and angle for VAD-OG anastomosis to minimize stroke risk.

6 March 2017 in International Journal of Numerical Methods for Heat & Fluid Flow
Verified
Journal Article
Closed access
Victor HuayamaveVictor Huayamave
Victor Huayamave
ACAndres Ceballos
Andres Ceballos
CBCarolina Barriento
Carolina Barriento
HSHubert Seigneur
Hubert Seigneur
SBStephen Barkaszi
Stephen Barkaszi
AKAlain Kassab
Alain Kassab
Purpose: Wind loading calculations are currently performed according to the ASCE 7 standard. Values in this standard were estimated from simplified models that do not necessarily take into account relevant flow characteristics. Thus, the standard does not have provisions to handle the majority of rooftop photovoltaic (PV) systems. Accurate solutions for this problem can be produced using a full-fledged three-dimensional computational fluid dynamics (CFD) analysis. Unfortunately, CFD requires enormous computation times, and its use would be unsuitable for this application which requires real-time solutions. To this end, a real-time response framework based on the proper orthogonal decomposition (POD) method is proposed. Design/methodology/approach: A real-time response framework based on the POD method was used. This framework used beforehand and off-line CFD solutions from an extensive data set developed using a predefined design space. Solutions were organized to form the basis snapshots of a POD matrix. The interpolation network using a radial-basis function (RBF) was used to predict the solution from the POD method given a set of values of the design variables. The results presented assume varying design variables for wind speed and direction on typical PV roof installations. Findings: The trained POD–RBF interpolation network was tested and validated by performing the fast-algebraic interpolation to obtain the pressure distribution on the PV system surface and they were compared to actual grid-converged fully turbulent 3D CFD solutions at the specified values of the design variables. The POD network was validated and proved that large-scale CFD problems can be parametrized and simplified by using this framework. Originality/value: The solar power industry, engineering design firms and the society as a whole could realize significant savings with the availability of a real-time in situ wind-load calculator that can prove essential for plug-and-play installation of PV systems. Additionally, this technology allows for automated parametric design optimization to arrive at the best fit for a set of given operating conditions. All these tasks are currently prohibited because of the massive computational resources and time required to address large-scale CFD analysis problems, all made possible by a simple but robust technology that can yield massive savings for the solar industry.

6 November 2021 in Fluids
Verified
Journal Article
Open access
PDF file
ADArka Das
Arka Das
RPRay Prather
Ray Prather
EDEduardo Divo
Eduardo Divo
MFMichael Farias
Michael Farias
AKAlain Kassab
Alain Kassab
WDWilliam DeCampli
William DeCampli
Around 8% of all newborns with a Congenital Heart Defect (CHD) have only a single functioning ventricle. The Fontan operation has served as palliation for this anomaly for decades, but the surgery entails multiple complications, and the survival rate is less than 50% by adulthood. A rapidly testable novel alternative is proposed by creating a bifurcating graft, or Injection Jet Shunt (IJS), used to “entrain” the pulmonary flow and thus provide assistance while reducing the caval pressure. A dynamically scaled Mock Flow Loop (MFL) has been configured to validate this hypothesis. Three IJS nozzles of varying diameters 2, 3, and 4 mm with three aortic anastomosis angles and pulmonary vascular resistance (PVR) reduction have been tested to validate the hypothesis and optimize the caval pressure reduction. The MFL is based on a Lumped-Parameter Model (LPM) of a non-fenestrated Fontan circulation. The best outcome was achieved with the experimental testing of a 3 mm IJS by producing an average caval pressure reduction of more than 5 mmHg while maintaining the clinically acceptable pulmonary flow rate (Qp) to systemic flow rate (Qs) ratio of ~1.5. Furthermore, alteration of the PVR helped in achieving higher caval pressure reduction with the 3 mm IJS at the expense of an increase in Qp/Qs ratio.

23 June 2015 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
WCWilliam D. Clark
William D. Clark
BEBenjamin A. Eslahpazir
Benjamin A. Eslahpazir
IAI. Ricardo Argueta-Morales
I. Ricardo Argueta-Morales
AKAlain Kassab
Alain Kassab
EDEduardo A. Divo
Eduardo A. Divo
WDWilliam M. DeCampli
William M. DeCampli