Kaiwen Guo

Mr. Kaiwen Guo

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2018 in Applied Optics
Verified
Journal Article
Open access
PDF file
KGKaiwen Guo
Kaiwen Guo
RMRamon A. Martinez
Ramon A. Martinez
GPGenevieve Plant
Genevieve Plant
LMLukasz Maksymiuk
Lukasz Maksymiuk
BJBrian Janiszewski
Brian Janiszewski
AIAgustin I. Ifarraguerri
Agustin I. Ifarraguerri
We generate a supercontinuum (SC) spectrum ranging from 1.57 μm to 12 μm (20 dB bandwidth) with a soft glass fiber cascade consisting of ZrF4-BaF2-LaF3-AlF3-NaF fiber, As2S3 fiber, and As2Se3 fiber pumped by a nanosecond thulium master oscillator power amplifier system. The highest on-time average power generated is 417 mW at 33% duty cycle. We observe a near-diffraction-limit beam quality across the wavelength range from 3 μm to 12 μm, even though the As2Se3 fiber is multimode below 12 μm. Our study also shows that parameters of the As2Se3 fiber, such as numerical aperture, core size, and core/cladding composition, have significant effects on the long wavelength edge of the generated SC spectrum. Our results suggest that the high numerical aperture of 0.76 and low-loss As2Se3/GeAs2Se5 core/cladding material all contribute to broad SC generation in the long-wave infrared spectral region. Also, among our results, 10 μm core diameter selenide fiber yields the best spectral expansion, while the 12 μm core diameter selenide fiber yields the highest output power.

27 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KGKaiwen Guo
Kaiwen Guo
TZTianqu Zhai
Tianqu Zhai
MPManoj Purushothama
Manoj Purushothama
ADAlexander Dobre
Alexander Dobre
SMShawn Meah
Shawn Meah
MIMohammed N. Islam
Mohammed N. Islam
We demonstrate a Contactless Vital Sign Monitoring (CVSM) system and road-test the system for in-cabin driver monitoring using a near-infrared indirect Time-of-Flight (ToF) camera. The CVSM measures both heart rate (HR) and respiration rate (RR) by leveraging the simultaneously measured grayscale and depth information from a ToF camera. For a camera-based driver monitoring system (DMS), key challenges from varying background illumination and motion-induced artifacts need to be addressed. In this study, active illumination and depth-based motion compensation are used to mitigate these two challenges. For HR measurements, active illumination allows the system to work under various lighting conditions, while our depth-based motion compensation has the advantage of directly measuring the motion of the driver without making prior assumptions about the motion artifacts. In addition, we can extract RR directly from the chest wall motion, circumventing the challenge of acquiring RR from the near-infrared photoplethysmography (PPG) signal of low signal quality. We investigate the system’s performance in various scenarios, including monitoring both drivers and passengers while driving on highways and local roads. Our results show that our CVSM system is ambient light agnostic, and the success rates of HR measurements on the highway are 82% and 71.9% for the passenger and driver, respectively. At the same time, we show that the system can measure RR on users driving on a highway with a mean deviation of −1.4 breaths per minute (BPM). With reliable HR and RR measurement in the vehicle, the CVSM system could one day be a key enabler to sudden sickness or drowsiness detection in DMS.

24 May 2019 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
RMRamon Arturo Martinez
Ramon Arturo Martinez
KGKaiwen Guo
Kaiwen Guo
TZTianqu Zhai
Tianqu Zhai
FTFred L. Terry
Fred L. Terry
LPLeland E. Pierce
Leland E. Pierce
AIAgustin I. Ifarraguerri
Agustin I. Ifarraguerri
We demonstrate a prototype mid-wave to long-wave infrared supercontinuum Fourier transform sensor capable of chemical detection and identification at 3.6 m. The system utilizes a 150 mW supercontinuum source with a continuous spectrum from 1.6 - 11 μm and an M $^2$ < 1.4 across all wavelengths to provide high brightness at the target. We measure scattering spectra from powder particles on soda-lime glass down to a concentration of 7.4 μg/cm $^2$ and show that they match theoretical spectra simulated via a Bobbert-Vlieger model. Unlike diffuse scattering measurements performed on commercial units, this stand-off sensor collects a numerical aperture of 0.0375 and received powers are four orders of magnitude lower than probe powers.

18 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KGKaiwen Guo
Kaiwen Guo
TZTianqu Zhai
Tianqu Zhai
EPElton Pashollari
Elton Pashollari
CVChristopher J Varlamos
Christopher J Varlamos
AAAymaan Ashhab Ahmed
Aymaan Ashhab Ahmed
MIMohammed N. Islam
Mohammed N. Islam
This study describes a contactless vital sign monitoring (CVSM) system capable of measuring heart rate (HR) and respiration rate (RR) using a low-power, indirect time-of-flight (ToF) camera. The system takes advantage of both the active infrared illumination as well as the additional depth information from the ToF camera to compensate for the motion-induced artifacts during the HR measurements. The depth information captures how the user is moving with respect to the camera and, therefore, can be used to differentiate where the intensity change in the raw signal is from the underlying heartbeat or motion. Moreover, from the depth information, the system can acquire respiration rate by directly measuring the motion of the chest wall during breathing. We also conducted a pilot human study using this system with 29 participants of different demographics such as age, gender, and skin color. Our study shows that with depth-based motion compensation, the success rate (system measurement within 10% of reference) of HR measurements increases to 75%, as compared to 35% when motion compensation is not used. The mean HR deviation from the reference also drops from 21 BPM to −6.25 BPM when we apply the depth-based motion compensation. In terms of the RR measurement, our system shows a mean deviation of 1.7 BPM from the reference measurement. The pilot human study shows the system performance is independent of skin color but weakly dependent on gender and age.

23 June 2020 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
RMRamon A. Martinez
Ramon A. Martinez
KGKaiwen Guo
Kaiwen Guo
FTFred L. Terry
Fred L. Terry
TZTianqu Zhai
Tianqu Zhai
MIMohammed N. Islam
Mohammed N. Islam
AIAgustin I. Ifarraguerri
Agustin I. Ifarraguerri
We experimentally measure the scattered reflectance of particles deposited on smooth substrates with a mid-wave to long-wave supercontinuum source and a FTIR based sensor at 3.6 m. We measure the scattering return from sparse particles of 1,3,5-Trinitroperhydro-1,3,5-triazine, caffeine, and acetaminophen deposited on smooth aluminum, silicon, and glass substrates. We also measure mono-disperse 5.4, 10.8, and 19.4 μ m diameter polystyrene spheres deposited on aluminum. We demonstrate that spectra obtained using our supercontinuum FTIR sensor can be accurately simulated using a Bobbert–Vlieger model, and non-spherical particle spectra can be approximated by spherical results. The Bobbert–Vlieger model can then be used to create a library that can account for the trace chemical and underlying substrate for standoff chemical identification.