Tianqu Zhai

Mr. Tianqu Zhai

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KGKaiwen Guo
Kaiwen Guo
TZTianqu Zhai
Tianqu Zhai
MPManoj Purushothama
Manoj Purushothama
ADAlexander Dobre
Alexander Dobre
SMShawn Meah
Shawn Meah
MIMohammed N. Islam
Mohammed N. Islam
We demonstrate a Contactless Vital Sign Monitoring (CVSM) system and road-test the system for in-cabin driver monitoring using a near-infrared indirect Time-of-Flight (ToF) camera. The CVSM measures both heart rate (HR) and respiration rate (RR) by leveraging the simultaneously measured grayscale and depth information from a ToF camera. For a camera-based driver monitoring system (DMS), key challenges from varying background illumination and motion-induced artifacts need to be addressed. In this study, active illumination and depth-based motion compensation are used to mitigate these two challenges. For HR measurements, active illumination allows the system to work under various lighting conditions, while our depth-based motion compensation has the advantage of directly measuring the motion of the driver without making prior assumptions about the motion artifacts. In addition, we can extract RR directly from the chest wall motion, circumventing the challenge of acquiring RR from the near-infrared photoplethysmography (PPG) signal of low signal quality. We investigate the system’s performance in various scenarios, including monitoring both drivers and passengers while driving on highways and local roads. Our results show that our CVSM system is ambient light agnostic, and the success rates of HR measurements on the highway are 82% and 71.9% for the passenger and driver, respectively. At the same time, we show that the system can measure RR on users driving on a highway with a mean deviation of −1.4 breaths per minute (BPM). With reliable HR and RR measurement in the vehicle, the CVSM system could one day be a key enabler to sudden sickness or drowsiness detection in DMS.

24 May 2019 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
RMRamon Arturo Martinez
Ramon Arturo Martinez
KGKaiwen Guo
Kaiwen Guo
TZTianqu Zhai
Tianqu Zhai
FTFred L. Terry
Fred L. Terry
LPLeland E. Pierce
Leland E. Pierce
AIAgustin I. Ifarraguerri
Agustin I. Ifarraguerri
We demonstrate a prototype mid-wave to long-wave infrared supercontinuum Fourier transform sensor capable of chemical detection and identification at 3.6 m. The system utilizes a 150 mW supercontinuum source with a continuous spectrum from 1.6 - 11 μm and an M $^2$ < 1.4 across all wavelengths to provide high brightness at the target. We measure scattering spectra from powder particles on soda-lime glass down to a concentration of 7.4 μg/cm $^2$ and show that they match theoretical spectra simulated via a Bobbert-Vlieger model. Unlike diffuse scattering measurements performed on commercial units, this stand-off sensor collects a numerical aperture of 0.0375 and received powers are four orders of magnitude lower than probe powers.

18 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KGKaiwen Guo
Kaiwen Guo
TZTianqu Zhai
Tianqu Zhai
EPElton Pashollari
Elton Pashollari
CVChristopher J Varlamos
Christopher J Varlamos
AAAymaan Ashhab Ahmed
Aymaan Ashhab Ahmed
MIMohammed N. Islam
Mohammed N. Islam
This study describes a contactless vital sign monitoring (CVSM) system capable of measuring heart rate (HR) and respiration rate (RR) using a low-power, indirect time-of-flight (ToF) camera. The system takes advantage of both the active infrared illumination as well as the additional depth information from the ToF camera to compensate for the motion-induced artifacts during the HR measurements. The depth information captures how the user is moving with respect to the camera and, therefore, can be used to differentiate where the intensity change in the raw signal is from the underlying heartbeat or motion. Moreover, from the depth information, the system can acquire respiration rate by directly measuring the motion of the chest wall during breathing. We also conducted a pilot human study using this system with 29 participants of different demographics such as age, gender, and skin color. Our study shows that with depth-based motion compensation, the success rate (system measurement within 10% of reference) of HR measurements increases to 75%, as compared to 35% when motion compensation is not used. The mean HR deviation from the reference also drops from 21 BPM to −6.25 BPM when we apply the depth-based motion compensation. In terms of the RR measurement, our system shows a mean deviation of 1.7 BPM from the reference measurement. The pilot human study shows the system performance is independent of skin color but weakly dependent on gender and age.

14 August 2024 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
JSJiho Song
Jiho Song
TZTianqu Zhai
Tianqu Zhai
HHHeung Sik Hahm
Heung Sik Hahm
YLYuancheng Li
Yuancheng Li
HMHui Mao
Hui Mao
JCJae Won Chang
Jae Won Chang

1 December 2024 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
TZTianqu Zhai
Tianqu Zhai
ZWZhang Wei
Zhang Wei
CMChenshuo Ma
Chenshuo Ma
MYMa Yanhui
Ma Yanhui
YPYannis Mantas Paulus
Yannis Mantas Paulus
Xueding WangXueding Wang
Xueding Wang
Alzheimer’s disease (AD), a predominant form of dementia, is marked by the presence of amyloid-β (Aβ) extracellular plaques and neurofibrillary tau tangles in the brain.1 Representing 60% to 80% of dementia cases, AD is one of the leading causes of mortality in the United States, affecting ∼6.7 million people aged 65 or older age in 2023.2 Despite the absence of effective treatment for AD, the detection and quantification of biomarkers play a pivotal role in the staging and early intervention of the disease, as pathological alterations can precede the clinical manifestations of cognitive decline by several years.3 In 2018, the National Institute on Aging and Alzheimer’s Association suggested the inclusion of Aβ, pathologic tau, and neurodegeneration in the pathological assessment and staging of AD for research purposes.4 Meanwhile, small vessel disease has been closely linked to AD, suggesting that cerebrovascular dysfunction should also be incorporated as a biomarker for AD assessment.5 Although numerous biomarkers were found to correlate with AD, the underlying causal relationship and mechanism remain poorly understood. To gain a comprehensive understanding of the disease, imaging techniques capable of providing diverse biomarker profiles are essential.

11 October 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
TZTianqu Zhai
Tianqu Zhai
WQWei Qian
Wei Qian
YPYannis M. Paulus
Yannis M. Paulus
Xueding WangXueding Wang
Xueding Wang
ZWZhang Wei
Zhang Wei
Alzheimer's disease (AD) is a neurodegenerative disease characterized by amyloid beta (Aβ)-containing extracellular plaques and tau-containing intracellular neurofibrillary tangles. Reliable and more accessible biomarkers along with associated imaging methods are essential for early diagnosis and to develop effective therapeutic interventions. Described here is an integrated photoacoustic microscopy (PAM) and optical coherence tomography (OCT) dual-modality imaging system for multiple ocular biomarker imaging in an AD mouse model. Anti-Aβ-conjugated Au nanochains (AuNCs) were engineered and administered to the mice to provide molecular contrast of Aβ. The retinal vasculature structure and Aβ deposition in AD mice and wild-type (WT) mice were imaged simultaneously by dual-wavelength PAM. OCT distinguished significant differences in retinal layer thickness between AD and WT animals. With the unique ability of imaging the multiple ocular biomarkers via a coaxial multimodality imaging system, the proposed system provides a new tool for investigating the progression of AD in animal models, which could contribute to preclinical studies of AD.