Cardiac output (CO) monitoring is a valuable tool for the diagnosis and management of critically ill patients. In the critical care setting, few studies have evaluated the level of agreement between CO estimated by transthoracic echocardiography (CO-TTE) and that measured by the reference method, pulmonary artery catheter (CO-PAC). The objective of the present study was to evaluate the precision and accuracy of CO-TTE relative to CO-PAC and the ability of transthoracic echocardiography to track variations in CO, in critically ill mechanically ventilated patients. Thirty-eight mechanically ventilated patients fitted with a PAC were included in a prospective observational study performed in a 16-bed university hospital ICU. CO-PAC was measured via intermittent thermodilution. Simultaneously, a second investigator used standard-view TTE to estimate CO-TTE as the product of stroke volume and the heart rate obtained during the measurement of the subaortic velocity time integral. Sixty-four pairs of CO-PAC and CO-TTE measurements were compared. The two measurements were significantly correlated (r = 0.95; p < 0.0001). The median bias was 0.2 L/min, the limits of agreement (LOAs) were –1.3 and 1.8 L/min, and the percentage error was 25%. The precision was 8% for CO-PAC and 9% for CO-TTE. Twenty-six pairs of ΔCO measurements were compared. There was a significant correlation between ΔCO-PAC and ΔCO-TTE (r = 0.92; p < 0.0001). The median bias was –0.1 L/min and the LOAs were –1.3 and +1.2 L/min. With a 15% exclusion zone, the four-quadrant plot had a concordance rate of 94%. With a 0.5 L/min exclusion zone, the polar plot had a mean polar angle of 1.0° and a percentage error LOAs of –26.8 to 28.8°. The concordance rate was 100% between 30 and –30°. When using CO-TTE to detect an increase in ΔCO-PAC of more than 10%, the area under the receiving operating characteristic curve (95% CI) was 0.82 (0.62–0.94) (p < 0.001). A ΔCO-TTE of more than 8% yielded a sensitivity of 88% and specificity of 66% for detecting a ΔCO-PAC of more than 10%. In critically ill mechanically ventilated patients, CO-TTE is an accurate and precise method for estimating CO. Furthermore, CO-TTE can accurately track variations in CO.
We aimed to assess variations in the portal vein pulsatility index (PI) during mechanical ventilation following cardiac surgery. Method. After ethical approval, we conducted a prospective monocentric study at Amiens University Hospital. Patients under mechanical ventilation following cardiac surgery were enrolled. Doppler evaluation of the portal vein (PV) was performed by transthoracic echography. The maximum velocity (VMAX) and minimum velocity (VMIN) of the PV were measured in pulsed Doppler mode. The PI was calculated using the following formula (VMAX − VMIN)/(VMax). A positive end-expiratory pressure (PEEP) incremental trial was performed from 0 to 15 cmH2O, with increments of 5 cmH2O. The PI (%) was assessed at baseline and PEEP 5, 10, and 15 cmH2O. Echocardiographic and hemodynamic parameters were recorded. Results. In total, 144 patients were screened from February 2018 to March 2019 and 29 were enrolled. Central venous pressure significantly increased for each PEEP increment. Stroke volumes were significantly lower after PEEP incrementation, with 52 mL (50–55) at PEEP 0 cmH2O and 30 mL (25–45) at PEEP 15 cmH2O, (p < 0.0001). The PI significantly increased with PEEP incrementation, from 9% (5–15) at PEEP 0 cmH2O to 15% (5–22) at PEEP 5 cmH2O, 34% (23–44) at PEEP 10 cmH2O, and 45% (25–49) at PEEP 15 cmH2O (p < 0.001). Conclusion. In the present study, PI appears to be a dynamic marker of the interaction between mechanical ventilation and right heart pressure after cardiac surgery. The PI could be a useful noninvasive tool to monitor venous congestion associated with mechanical ventilation.
Background: Atrial fibrillation (AF) is the most documented arrhythmia in COVID-19 pneumonia. Left atrial (LA) strain (LAS) analysis, a marker of LA contractility, have been associated with the development of AF in several clinical situations. We aimed to assess the diagnostic ability of LA strain parameters to predict AF in patients with severe hypoxemic COVID-19 pneumonia. We conducted a prospective single center study in Amiens University Hospital intensive care unit (ICU) (France). Adult patients with severe or critical COVID-19 pneumonia according to the World Health Organization definition and in sinus rhythm were included. Transthoracic echocardiography was performed within 48 h of ICU admission. LA strain analysis was performed by an automated software. The following LA strain parameters were recorded: LA strain during reservoir phase (LASr), LA strain during conduit phase (LAScd) and LA strain during contraction phase (LASct). The primary endpoint was the occurrence of AF during ICU stay. Results: From March 2020 to February of 2021, 79 patients were included. Sixteen patients (20%) developed AF in ICU. Patients of the AF group were significantly older with a higher SAPS II score than those without AF. LAScd and LASr were significantly more impaired in the AF group compared to the other group (− 8.1 [− 6.3; − 10.9] vs. − 17.2 [− 5.0; − 10.2] %; P < 0.001 and 20.2 [12.3;27.3] % vs. 30.5 [23.8;36.2] %; P = 0.002, respectively), while LASct did not significantly differ between groups (p = 0.31). In a multivariate model, LAScd and SOFA cv were significantly associated with the occurrence of AF. A LAScd cutoff value of − 11% had a sensitivity of 76% and a specificity of 75% to identify patients with AF. The 30-day cumulative risk of AF was 42 ± 9% with LAScd > − 11% and 8 ± 4% with LAScd ≤ − 11% (log rank test P value < 0.0001). Conclusion: For patients with severe COVID-19 pneumonia, development of AF during ICU stay is common (20%). LAS parameters seem useful in predicting AF within the first 48 h of ICU admission. Trial registration : NCT04354558.