Jihao Liu

Dr. Jihao Liu

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Journal of Pure and Applied Algebra
Verified
Journal Article
Closed access
JLJihao Liu
Jihao Liu
LXLiudan Xiao
Liudan Xiao

23 January 2019 in Advances in Mechanical Engineering
Verified
Journal Article
Open access
PDF file
EGEnguang Guan
Enguang Guan
HMHuihua Miao
Huihua Miao
PLPeibo Li
Peibo Li
JLJihao Liu
Jihao Liu
YZYanzheng Zhao
Yanzheng Zhao
In view of the shortcomings of traditional hydraulic support system, such as poor mobility and limited range of adjustment, a new configuration with double parallelogram structure is proposed. Combining the kinematic diagram of the mechanism of the new support system and the relevant parameters of the balance moment, using the kinematic vector closed-loop modeling method and D’Alembert’s principle, the relationship equation between the generalized coordinates of the hydraulic support and the geometric position parameters is obtained, and the analysis model with plural-freedom is established. Dynamic response characteristics and natural frequencies of column hydraulic cylinder and balance hydraulic cylinder are analyzed. The results demonstrate that the natural frequencies of the improved balance hydraulic cylinder and column hydraulic cylinder have been greatly improved, and the safety performance of the hydraulic support has been greatly increased.

3 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
WSWenyuan Sun
Wenyuan Sun
JLJihao Liu
Jihao Liu
YZyuyun zhao
yuyun zhao
Guoyan ZhengGuoyan Zheng
Guoyan Zheng
Pedicle screw insertion with robot assistance dramatically improves surgical accuracy and safety when compared with manual implantation. In developing such a system, hand–eye calibration is an essential component that aims to determine the transformation between a position tracking and robot-arm systems. In this paper, we propose an effective hand–eye calibration method, namely registration-based hand–eye calibration (RHC), which estimates the calibration transformation via point set registration without the need to solve the AX=XB equation. Our hand–eye calibration method consists of tool-tip pivot calibrations in two-coordinate systems, in addition to paired-point matching, where the point pairs are generated via the steady movement of the robot arm in space. After calibration, our system allows for robot-assisted, image-guided pedicle screw insertion. Comprehensive experiments are conducted to verify the efficacy of the proposed hand–eye calibration method. A mean distance deviation of 0.70 mm and a mean angular deviation of 0.68° are achieved by our system when the proposed hand–eye calibration method is used. Further experiments on drilling trajectories are conducted on plastic vertebrae as well as pig vertebrae. A mean distance deviation of 1.01 mm and a mean angular deviation of 1.11° are observed when the drilled trajectories are compared with the planned trajectories on the pig vertebrae.

3 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JLJihao Liu
Jihao Liu
WSWenyuan Sun
Wenyuan Sun
YZyuyun zhao
yuyun zhao
Guoyan ZhengGuoyan Zheng
Guoyan Zheng
In robot-assisted ultrasound-guided needle biopsy, it is essential to conduct calibration of the ultrasound probe and to perform hand-eye calibration of the robot in order to establish a link between intra-operatively acquired ultrasound images and robot-assisted needle insertion. Based on a high-precision optical tracking system, novel methods for ultrasound probe and robot hand-eye calibration are proposed. Specifically, we first fix optically trackable markers to the ultrasound probe and to the robot, respectively. We then design a five-wire phantom to calibrate the ultrasound probe. Finally, an effective method taking advantage of steady movement of the robot but without an additional calibration frame or the need to solve the AX=XB equation is proposed for hand-eye calibration. After calibrations, our system allows for in situ definition of target lesions and aiming trajectories from intra-operatively acquired ultrasound images in order to align the robot for precise needle biopsy. Comprehensive experiments were conducted to evaluate accuracy of different components of our system as well as the overall system accuracy. Experiment results demonstrated the efficacy of the proposed methods.

7 April 2023 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
WSWenyuan Sun
Wenyuan Sun
YZyuyun zhao
yuyun zhao
JLJihao Liu
Jihao Liu
Guoyan ZhengGuoyan Zheng
Guoyan Zheng

1 December 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
FCFeng Cao
Feng Cao
PDPaul D. Docherty
Paul D. Docherty
CJChunming Jiang
Chunming Jiang
JLJihao Liu
Jihao Liu
WYWeixin Yan
Weixin Yan
XCXiaoQi Chen
XiaoQi Chen
Accurate measurement of contact force/torque (CFT) is critical for robotic manipulators to interact effectively with their environment. This paper introduces an adaptive Kalman-filter-based observer for sensorless measurement of the CFT exerted on manipulators. To reduce the predicted state noise, an adaptive Weighted Moving Average (AWMA) with a variable span is proposed. This approach facilitates the use of larger diagonal elements in the predicted noise covariance matrix and enhances the observer’s responsiveness without compromising accuracy. The AWMA span is adjusted online to optimize the balance between measurement accuracy and response time. Experimental validation shows that the proposed observer is applicable to robots with single and multiple manipulators across different scenarios. Compared to a method using only the conventional Kalman filter, the proposed method reduces estimation errors and improves response speed. By utilizing available inertial and kinematic information, physical force/torque sensors are eliminated during modeling, validation, and deployment, providing a more flexible and cost-effective solution for sensorless CFT estimation.