Pedicle screw insertion with robot assistance dramatically improves surgical accuracy and safety when compared with manual implantation. In developing such a system, hand–eye calibration is an essential component that aims to determine the transformation between a position tracking and robot-arm systems. In this paper, we propose an effective hand–eye calibration method, namely registration-based hand–eye calibration (RHC), which estimates the calibration transformation via point set registration without the need to solve the equation. Our hand–eye calibration method consists of tool-tip pivot calibrations in two-coordinate systems, in addition to paired-point matching, where the point pairs are generated via the steady movement of the robot arm in space. After calibration, our system allows for robot-assisted, image-guided pedicle screw insertion. Comprehensive experiments are conducted to verify the efficacy of the proposed hand–eye calibration method. A mean distance deviation of 0.70 mm and a mean angular deviation of 0.68° are achieved by our system when the proposed hand–eye calibration method is used. Further experiments on drilling trajectories are conducted on plastic vertebrae as well as pig vertebrae. A mean distance deviation of 1.01 mm and a mean angular deviation of 1.11° are observed when the drilled trajectories are compared with the planned trajectories on the pig vertebrae.
In robot-assisted ultrasound-guided needle biopsy, it is essential to conduct calibration of the ultrasound probe and to perform hand-eye calibration of the robot in order to establish a link between intra-operatively acquired ultrasound images and robot-assisted needle insertion. Based on a high-precision optical tracking system, novel methods for ultrasound probe and robot hand-eye calibration are proposed. Specifically, we first fix optically trackable markers to the ultrasound probe and to the robot, respectively. We then design a five-wire phantom to calibrate the ultrasound probe. Finally, an effective method taking advantage of steady movement of the robot but without an additional calibration frame or the need to solve the equation is proposed for hand-eye calibration. After calibrations, our system allows for in situ definition of target lesions and aiming trajectories from intra-operatively acquired ultrasound images in order to align the robot for precise needle biopsy. Comprehensive experiments were conducted to evaluate accuracy of different components of our system as well as the overall system accuracy. Experiment results demonstrated the efficacy of the proposed methods.
7 April 2023 in International Journal of Computer Assisted Radiology and Surgery
Current Deep Learning (DL)-based methods for vertebra localization in biplanar X-ray images mainly focus on two-dimensional (2D) information and neglect the projective geometry, limiting the accuracy of 3D navigation in X-ray-guided spine surgery. A 3D vertebra localization method from calibrated biplanar X-ray images is highly desired to address the problem. In this study, a projective-geometry-aware network for localizing 3D vertebrae in calibrated biplanar X-ray images, referred to as ProVLNet, is proposed. The network design of ProVLNet features three components: a Siamese 2D feature extractor to extract local appearance features from the biplanar X-ray images, a spatial alignment fusion module to incorporate the projective geometry in fusing the extracted 2D features in 3D space, and a 3D landmark regression module to regress the 3D coordinates of the vertebrae from the 3D fused features. Evaluated on two typical and challenging datasets acquired from the lumbar and the thoracic spine, ProVLNet achieved an identification rate of 99.53% and 98.98% and a point-to-point error of 0.64 mm and 1.38 mm, demonstrating superior performance of our proposed approach over the state-of-the-art (SOTA) methods.
Periacetabular osteotomy (PAO) is an effective approach for the surgical treatment of developmental dysplasia of the hip (DDH). However, due to the complex anatomical structure around the hip joint and the limited field of view (FoV) during the surgery, it is challenging for surgeons to perform a PAO surgery. To solve this challenge, we propose a robot-assisted, augmented reality (AR)-guided surgical navigation system for PAO. The system mainly consists of a robot arm, an optical tracker, and a Microsoft HoloLens 2 headset, which is a state-of-the-art (SOTA) optical see-through (OST) head-mounted display (HMD). For AR guidance, we propose an optical marker-based AR registration method to estimate a transformation from the optical tracker coordinate system (COS) to the virtual space COS such that the virtual models can be superimposed on the corresponding physical counterparts. Furthermore, to guide the osteotomy, the developed system automatically aligns a bone saw with osteotomy planes planned in preoperative images. Then, it provides surgeons with not only virtual constraints to restrict movement of the bone saw but also AR guidance for visual feedback without sight diversion, leading to higher surgical accuracy and improved surgical safety. Comprehensive experiments were conducted to evaluate both the AR registration accuracy and osteotomy accuracy of the developed navigation system. The proposed AR registration method achieved an average mean absolute distance error (mADE) of 1.96 ± 0.43 mm. The robotic system achieved an average center translation error of 0.96 ± 0.23 mm, an average maximum distance of 1.31 ± 0.20 mm, and an average angular deviation of 3.77 ± 0.85°. Experimental results demonstrated both the AR registration accuracy and the osteotomy accuracy of the developed system.