Artifact Subspace Reconstruction (ASR) is an adaptive method for the online or offline correction of artifacts comprising multichannel electroencephalography (EEG) recordings. It repeatedly computes a principal component analysis (PCA) on covariance matrices to detect artifacts based on their statistical properties in the component subspace. We adapted the existing ASR implementation by using Riemannian geometry for covariance matrix processing. EEG data that were recorded on smartphone in both outdoors and indoors conditions were used for evaluation (N = 27). A direct comparison between the original ASR and Riemannian ASR (rASR) was conducted for three performance measures: reduction of eye-blinks (sensitivity), improvement of visual-evoked potentials (VEPs) (specificity), and computation time (efficiency). Compared to ASR, our rASR algorithm performed favorably on all three measures. We conclude that rASR is suitable for the offline and online correction of multichannel EEG data acquired in laboratory and in field conditions.
Recent technological progress has allowed the development of low-cost and highly portable brain sensors such as pre-amplified dry-electrodes to measure cognitive activity out of the laboratory. This technology opens promising perspectives to monitor the “brain at work” in complex real-life situations such as while operating aircraft. However, there is a need to benchmark these sensors in real operational conditions. We therefore designed a scenario in which twenty-two pilots equipped with a six-dry-electrode EEG system had to perform one low load and one high load traffic pattern along with a passive auditory oddball. In the low load condition, the participants were monitoring the flight handled by a flight instructor, whereas they were flying the aircraft in the high load condition. At the group level, statistical analyses disclosed higher P300 amplitude for the auditory target (Pz, P4 and Oz electrodes) along with higher alpha band power (Pz electrode), and higher theta band power (Oz electrode) in the low load condition as compared to the high load one. Single trial classification accuracy using both event-related potentials and event-related frequency features at the same time did not exceed chance level to discriminate the two load conditions. However, when considering only the frequency features computed over the continuous signal, classification accuracy reached around 70% on average. This study demonstrates the potential of dry-EEG to monitor cognition in a highly ecological and noisy environment, but also reveals that hardware improvement is still needed before it can be used for everyday flight operations.
Objective. Our aim was the development and validation of a modular signal processing and classification application enabling online electroencephalography (EEG) signal processing on off-the-shelf mobile Android devices. The software application SCALA (Signal ProCessing and CLassification on Android) supports a standardized communication interface to exchange information with external software and hardware. Approach. In order to implement a closed-loop brain-computer interface (BCI) on the smartphone, we used a multiapp framework, which integrates applications for stimulus presentation, data acquisition, data processing, classification, and delivery of feedback to the user. Main Results. We have implemented the open source signal processing application SCALA. We present timing test results supporting sufficient temporal precision of audio events. We also validate SCALA with a well-established auditory selective attention paradigm and report above chance level classification results for all participants. Regarding the 24-channel EEG signal quality, evaluation results confirm typical sound onset auditory evoked potentials as well as cognitive event-related potentials that differentiate between correct and incorrect task performance feedback. Significance. We present a fully smartphone-operated, modular closed-loop BCI system that can be combined with different EEG amplifiers and can easily implement other paradigms.
The streaming and recording of smartphone sensor signals is desirable for mHealth, telemedicine, environmental monitoring and other applications. Time series data gathered in these fields typically benefit from the time-synchronized integration of different sensor signals. However, solutions required for this synchronization are mostly available for stationary setups. We hope to contribute to the important emerging field of portable data acquisition by presenting open-source Android applications both for the synchronized streaming (Send-a) and recording (Record-a) of multiple sensor data streams. We validate the applications in terms of functionality, flexibility and precision in fully mobile setups and in hybrid setups combining mobile and desktop hardware. Our results show that the fully mobile solution is equivalent to well-established desktop versions. With the streaming application Send-a and the recording application Record-a, purely smartphone-based setups for mobile research and personal health settings can be realized on off-the-shelf Android devices.
Objective. In this report we present the fEEGrid, an electrode array applied to the forehead that allows convenient long-term recordings of electroencephalography (EEG) signals over many hours. Approach. Twenty young, healthy participants wore the fEEGrid and completed traditional EEG paradigms in two sessions on the same day. The sessions were eight hours apart, participants performed the same tasks in an early and a late session. For the late session fEEGrid data were concurrently recorded with traditional cap EEG data. Main results. Our analyses show that typical event-related potentials responses were captured reliably by the fEEGrid. Single-trial analyses revealed that classification was possible above chance level for auditory and tactile oddball paradigms. We also found that the signal quality remained high and impedances did not deteriorate, but instead improved over the course of the day. Regarding wearing comfort, all participants indicated that the fEEGrid was comfortable to wear and did not cause any pain even after 8 h of wearing it. Significance. We show in this report, that high quality EEG signals can be captured with the fEEGrid reliably, even in long-term recording scenarios and with a signal quality that may be considered suitable for online brain-computer Interface applications.
Objective: We investigated a method for an effective artifact attenuation in mobile EEG paradigms. Our method is based on Artifact Subspace Reconstruction (ASR), which is designed for online and offline applications to correct artifacts in multichannel EEG data automatically. ASR is an adaptive procedure which repeatedly computes a principal component analysis on covariance matrices of the channel data to detect artifacts based on their statistical properties in the component subspace. We developed and evaluated an adaptation of the existing ASR implementation in which we explored whether use of Riemannian geometry helps to attenuate typical EEG artifacts as well as natural walking related movement artifacts more reliably and with lower computational costs. Methods: Mobile EEG was recorded while participants were sitting and walking outdoors. A small, wireless 24-channel EEG system with gyroscope sensors and a smartphone were used for EEG acquisition and behavioral response recording. We compared artifact-correction sensitivities of the ASR and Riemann-ASR (rASR) methods by analysing the signal to noise ratio (SNR) of eye blinks and natural outdoors walking artifacts. In a second analysis, we evaluated artifact correction specificities by comparing properties of an auditory N100 for response sounds confirming screen touches. Finally, we compared both ASR variants with independent component analysis (ICA), the current gold standard in EEG artifact correction. Results: We found that our rASR implementation reduced computing time significantly compared to ASR and ICA. Moreover, first results suggest that rASR also outperformed ASR with regard to sensitivity and specificity measures, that is, rASR artifact correction resulted in a larger N100 SNR and stronger eye-blink and movement artifact suppression. Conclusions: Our results demonstrate that rASR may be an efficient and objective method for the online correction of multi-channel EEG data acquired during mobile and non-mobile conditions.