Mahmoud aziz

Dr. Mahmoud aziz


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2022 in Buildings
Verified
Journal Article
Open access
PDF file
MAMahmoud aziz
Mahmoud aziz
Jong Wan HuJong Wan Hu
Jong Wan Hu
SSshim won sup
shim won sup
FAFathi Abdelazeem
Fathi Abdelazeem
GEGalal Elsamak
Galal Elsamak
Many structural elements are subjected to a significant torsional moment that affects the structural design and may require strengthening. This paper presents different effective strengthening techniques to enhance the torsional capacity of reinforced concrete (RC) beams. An experimental and numerical investigation was undertaken to evaluate the efficacy of utilizing various strengthening systems. The experimental program included six full-scale RC beams with a cross-section dimension of (150 mm × 300 mm) and a length of 1500 mm, split into one beam without strengthening as a control beam, and six beams strengthened with various materials. The various strengthening materials were wrapped aluminum strips with anchorage bolts, wrapped stainless steel strips with anchorage bolts, wrapped glass fiber reinforcement polymer (GFRP), one layer of wrapped steel wire, and two layers of wrapped steel wire meshes along the beam. The results showed that the ultimate torque of the beam strengthened by wrapped aluminum strips and the beam strengthened by wrapped stainless steel strips was larger than the control beam by about 32% and 40%, respectively, because the strips acted as an external reinforcement. In addition to the strengthening systems, using aluminum strips and stainless steel strips is effective in raising the capacity to a similar degree despite the high cost of the stainless steel strips. The ultimate torque of the beams strengthened by GFRP, one-layered wrapped steel wire meshes, and two-layered wrapped steel wire meshes along the beam is larger than the control beam by about 62%, 118%, and 163%, respectively, in addition to the ultimate angle of twist, which was larger than the control beam by about 53%, 93%, and 126%, respectively. This showed that the strengthening using the two-layered wrapped steel wire meshes along the beam would be very significant in increasing the ultimate torque strength. Moreover, the strengthened beam by two-layered fully wrapped steel wire meshes along the beam developed the highest ductility factor compared to all strengthened beams; in contrast, the beam strengthened by GFRP had less ductility. To verify the outcomes of the experimental tests, a finite-element program, ABAQUS, was performed. Finally, an excellent agreement between the experimental and numerical results was obtained.

21 December 2022 in Materials
Verified
Journal Article
Open access
PDF file
GEGalal Elsamak
Galal Elsamak
AAAli Abdullah
Ali Abdullah
MSmagdy salama
magdy salama
Jong Wan HuJong Wan Hu
Jong Wan Hu
MAMahmoud aziz
Mahmoud aziz
The punching shear failure of reinforced concrete (RC) flat slabs is an undesirable type of failure, as it is sudden and brittle. This paper presents an experimental and numerical study to explore the behavior of flat slabs made of different types of concrete under the influence of punching shear. Experimental tests were carried out on four groups of flat slabs, each group representing a different type of concrete: ordinary normal concrete (NC), high-strength concrete (HSC), strain-hardening cementitious composite concrete (SHCC), and ultra-high-performance fiber concrete (UHPFC). Each group consisted of six slabs, one representing an unreinforced control slab other than the reinforcement of the bottom mesh, and the others representing slabs internally reinforced with SHCC-filled steel tubes and high-strength bolts. An analytical equation was used to predict the punching shear capacity of slabs internally reinforced using steel assemblies. A numerical model was proposed using the ABAQUS program, and was validated by comparing its results with our experimental results. Finally, a case study was performed on large-scale slabs. The results showed that using steel assemblies inside NC slabs increased the slab’s punching shear capacity but does not completely prevent punching shear failure. Internally unreinforced slabs made of UHPFC and SHCC were able to avoid punching shear failure and collapse in a ductile bending pattern due to the high compressive and tensile strength of these types of concrete. The proposed analytical method succeeded in predicting the collapse load of slabs reinforced with steel assemblies with a difference not exceeding 9%.

13 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
MAMahmoud aziz
Mahmoud aziz
Jong Wan HuJong Wan Hu
Jong Wan Hu
ASAyman S.Mohamed
Ayman S.Mohamed
AEAhmed Saudi Abdel Maula El-sayed
Ahmed Saudi Abdel Maula El-sayed
Currently, the costs of building materials, especially cement, are increasing. Waste marble powder (WMP) could be used as a cement replacement material to produce environmentally friendly concrete to help preserve resources and reduce environmental pollution. The study’s goals are (1) to evaluate the effects of using marble powder in place of cement in high-strength concrete (HSC) on the material’s mechanical properties and durability characteristics. (2) The study is expanded to assess the effect of using partial WMP on the shear behavior of HSC beams under static loads. Eight half-scale simply supported reinforced beams with and without WMP have been tested. Each beam’s cross-section was 120 × 200 mm, and each beam had a total length of 1000 mm. The ratios of the used WMP were 0%, 2.5%, 5%, 7.5% by weight, and two different stirrup ratios, 0% and 0.47%, were used. When applied to HSC beams with and without WMP, the shear strength provisions of two of the most used codes, such as the locally used Egyptian Code (ECP 207) and the internationally used American Concrete Institute’s (ACI-2019), were examined. Using the ABAQUS software, the experimental results were compared to the findings of the nonlinear finite element analysis. The results established that partial replacement of cement by WMP led to increases in the concrete’s compressive and tensile strengths of about 15% and 16%, respectively. When tested specimens were exposed to acid attack, there were slight losses in weight and compressive strength (1.25% to 2.47%) for both with and without the addition of WMP. Both the concrete with and without WMP showed the same level of water absorption. Additionally, WMP led to an enhancement in the shear capacities for all beams. Increasing the WMP ratio from 0% to 2.5%, 5%, and 7.5% increased the shear capacity by about 13%, 20%, and 28%, respectively, for beams without stirrups, while for beams with stirrups, the shear capacity improved by 12%, 19%, and 25%, respectively. The enhancement in the beams’ shear capacities could be attributed to the advanced concrete matrix produced by WMP’s extremely small particle size.

4 February 2022 in Buildings
Verified
Journal Article
Open access
PDF file
MAMahmoud aziz
Mahmoud aziz
MOMoustafa Omar
Moustafa Omar
MEMohamed A. Elnaggar
Mohamed A. Elnaggar
AEAhmed Saudi Abdel Maula El-sayed
Ahmed Saudi Abdel Maula El-sayed
Using lightweight reinforced concrete beams with glass fiber bars (GFRP) is one approach for achieving the requirement seismic design idea of “strong-columns weak-beams”. Twelve full-scale normal-strength concrete (NC with fc` = 32 MPa) and high-strength lightweight concrete (HSLWC with fc` = 42, 49 and 52 MPa) exterior beam-column joints have been tested under cyclic loadings. The beams were reinforced with conventional steel bars (CS) and GFRP using steel fibers (SF). The experimental joint shear force was compared with that estimated by some international codes such as the American Concrete Institute (ACI-19), the Egyptian code (ECP-07), and the New Zealand Code (NZS-06). Nonlinear finite element analysis (ABAQUS) was carried out. In the present study, three main parameters were explored (1) HSLWC, (2) GFRP ratios equal to 0.70%, 1.03% and 1.37%, (3) SF ratios equal to 0.0%, 0.75% and 1.50%. The findings of the experiment revealed that increasing the concrete strength from NC with conventional steel bars to high-strength lightweight concrete HSLWC (fc` = 42 MPa) with the same ratio of GFRP bars enhanced the first cracking load by about 25%. Increasing the SF ratio to 1.50% enhanced the failure load by 18–24% when compared with non-fiber specimens. The predicted joint shear strength estimated using the equations of the ACI 318-19 and ECP-07 are conservative for HSLWC exterior beam-column connection reinforced with GFRP bars but the predicted joint shear strength by using the equations of the NZS-07 is on the borderline for some cases. The finite element program ABAQUS can be used successfully to forecast the behavior of HSLWC beam-column connections reinforced with GFRP under seismic loadings.

24 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
MAMahmoud aziz
Mahmoud aziz
Mosbeh KaloopMosbeh Kaloop
Mosbeh Kaloop
Jong Wan HuJong Wan Hu
Jong Wan Hu
AEAhmed Saudi Abdel Maula El-sayed
Ahmed Saudi Abdel Maula El-sayed
In this study, the shear strength of sixteen full-scale over-reinforced concrete beams with and without nano silica (NS), constructed from high-strength concrete (HSC), was investigated both experimentally and analytically. Nano silica was used as a partial replacement for Portland cement. According to the NS ratio, the tested beams were divided into four groups: 0%, 1%, 2%, and 3%. Shear span to effective depth (a/d) ratios of 1.5 and 2.5 were used in each group, and two different stirrups ratios (ρv) were employed as 0% and 0.38%. The shear strength provisions used by some international codes, such as the American Concrete Institute (ACI-2019), the Eurocode 2 (EC-2), and the Egyptian Code (ECP 207), were examined when applied to HSC beams with and without NS. The most important factors to consider were the effect of using NS on the shear span to effective depth (a/d) ratio and the shear strength of the beams with and without stirrups. The experimental results were validated using a nonlinear finite element analysis using the computer program ABAQUS. The experimental results showed that increasing the NS ratio reduced the number of cracks, and increased the cracks spacing, as well as reducing crack width. In specimens without stirrups, these effects were more obvious. A rise in the (a/d) ratio increased the number of cracks along the beam length, notably in the mid-span region. For specimens without stirrups and with an (a/d) of 1.5, raising NS from 0% to 1%, 2%, and 3% increased the ultimate load by 13%, 30%, and 39%, respectively, whereas for specimens with an (a/d) of 2.5, the ultimate load increased with approximately the same increase as that in beams with an (a/d) of 1.5 due to using NS. Additionally, the addition of NS to concrete boosted the contribution of the concrete to the shear strength, as shown by the results of beams without stirrups. For specimens with stirrups and an (a/d) of 1.5, raising NS from 0% to 1%, 2%, and 3% increased the ultimate load by 8%, 21%, and 30%, respectively. Additionally, for specimens with stirrups and an (a/d) of 2.5, the ultimate load increased with approximately the same increase as that in beams with stirrups and an (a/d) of 1.5 due to using NS. The test findings indicate that the shear strength calculated using the equations of the ACI 318-19 is more conservative than EC-2 and ECP 207 for NS concrete beams. The finite element program ABAQUS may be successfully used to predict the shear strength of NS concrete beams.

30 August 2022 in Buildings
Verified
Journal Article
Open access
PDF file
MAMahmoud aziz
Mahmoud aziz
Jong Wan HuJong Wan Hu
Jong Wan Hu
AEAhmed Saudi Abdel Maula El-sayed
Ahmed Saudi Abdel Maula El-sayed
Waste Glass Powder (WGP) could be used as a cement replacement additive to manufacture concrete and solving the problem of environmental pollution. The experimental program was made up of ten simply supported reinforced High-Strength Concrete (HSC) deep beams tested under static loadings. Five beams were with WGP, while the other five beams were without WGP. Eight beams had web openings while two reference beams were without openings. The principal studied parameters were the effect of using WGP, and the location and size of web openings. Using the three-dimensional finite element computer program ABAQUS, a numerical simulation for comparing the shear strength and behavior of tested deep beams has been suggested. The comparison between experimental failure loads of studied beams with that estimated by the Strut-and-Tie model was carried out. Three codes of practice were used to make this comparison: the American Concrete Institute (ACI 318-19), the New Zealand Code (NZS-06), and the Japan Society of Civil Engineering (JSCE-07). The results showed that using WGP in similar deep beams with web openings enhances the cracking shear strength (by about 17–25%) and the ultimate shear strength (by about 12–41%). The improvement in the ultimate failure load could be attributed to the developed concrete microstructures caused by WGP’s very fine grains, producing further gel, and decreasing the number of voids in the concrete matrix. The suggested finite element simulation accurately predicts the behavior of HSC deep beams with and without WGP beams and with web openings.