An improvement in dielectric strength is required in vacuum circuit breakers (VCBs) intended for use in higher voltage systems. In order to develop higher voltage VCBs, it is important to improve the dielectric strength in a vacuum based on consideration of the vacuum breakdown mechanism. Particularly for gaps longer than 10 mm, little is known about the breakdown mechanisms and their quantitative analyses in a vacuum. This paper discusses the breakdown conditioning characteristics of long gap electrodes, under a non-uniform electric field in a vacuum. We treat gap lengths of up to 50 mm in this paper. The conditioning characteristics are investigated under impulse voltage applications. A negative standard lightning impulse voltage was applied to rod-plane electrodes made of Cu-Cr and SUS304 for different tip radii and gap distances until the conditioning effect was completed. We observed illumination spots on electrodes at each breakdown during the conditioning process and calculated the corresponding breakdown field strengths. Experimental results revealed that the tendency of breakdowns associated with long gaps is different from that for the short gaps. As a result, we clarified that the breakdown field strengths are nearly constant at 110-120 kV/mm at the distances longer than 10 mm, and the breakdown field strength is at its maximum when the gap distance is about 5 mm.
In this article, we demonstrate the value of using decoupled neural oscillators in conjunction with appropriate mechanical designs for snake-like robots engaging in field locomotion. Even though our typical wheeled snake robot with decoupled neural oscillators incorporating angle joint feedback can generate consistent lateral undulation, it lacks robustness. A purely decoupled actuation strategy is not practical for field locomotion. However, the application of one-way wheels and elasticity between the modules improves robustness, allowing our robot to traverse outdoor open terrain. On the other hand, the physical form of the undulatory motion must be varied to pass through intricate narrow-field environments. The lack of neural constraints between the modules passively enables this variability and also facilitates each module independently gaining propulsion (i.e., by means of reflexive thrust via sensory feedback to the neural oscillator and one-way traction generated by one-way side rollers). The designed robot is able to engage in fast creeping motion through an environment containing randomly distributed logs. The results of the field experiments show that the specially designed mechanisms in conjunction with decoupled oscillators can enhance robustness, variability, and independent local propulsion.
We propose a method to achieve autonomous gait transition according to speed for a quadruped robot pacing at medium speeds. We verified its effectiveness through experiments with the simulation model and the robot we developed. In our proposed method, a central pattern generator (CPG) is applied to each leg. Each leg is controlled by a PD controller based on output from the CPG. The four CPGs are coupled, and a hard-wired CPG network generates a pace pattern by default. In addition, we feed the body tilt back to the CPGs in order to adapt to the body oscillation that changes according to the speed. As a result, our model and robot achieve stable changes in speed while autonomously generating a walk at low speeds and a rotary gallop at high speeds, despite the fact that the walk and rotary gallop are not preprogramed. The body tilt angle feedback is the only factor involved in the autonomous generation of gaits, so it can be easily used for various quadruped robots. Therefore, it is expected that the proposed method will be an effective control method for quadruped robots.
We propose a mechanical design for a simple teleoperated unmanned ground vehicle (UGV) to negotiate uneven terrain. UGVs are typically classified into legged, legged-wheeled, wheeled, and tanked forms. Legged vehicles can significantly shift their center of gravity (COG) by positioning their multi-articulated legs at appropriate trajectories, stepping over a high obstacle. To realize a COG movable mechanism with a small number of joints, a number of UGVs have been developed that can shift their COG by moving a mass at a high position above the body. However, these tend to pose a risk of overturning, and the mass must be moved quite far to climb a high step. To address these issues, we design a novel COG shift mechanism, in which the COG can be shifted forward and backward inside the body by moving most of its internal devices. Since this movable mass includes DC motors for driving both tracks, we can extend the range of the COG movement. We demonstrate that a conventional tracked vehicle prototype can traverse a step and a gap between two steps, as well as climb stairs and a steep slope, with a human operating the vehicle movement and the movable mass position.
Our goal is to design a neuromorphic locomotion controller for a prospective bioinspired quadruped robot driven by artificial muscle actuators. In this paper, we focus on achieving a running gait called a pace, in which the ipsilateral pairs of legs move in phase, while the two pairs together move out of phase, by a quadruped robot with realistic legs driven by pneumatic muscle actuators. The robot is controlled by weakly coupled two-level central pattern generators to generate a pace gait with leg loading feedback. Each leg is moved through four sequential phases like an animal, i.e., touch-down, stance, lift-off, and swing phases. We find that leg loading feedback to the central pattern generator can contribute to stabilizing pace running with an appropriate cycle autonomously determined by synchronizing each leg’s oscillation with the roll body oscillation without a human specifying the cycle. The experimental results conclude that our proposed neuromorphic controller is beneficial for achieving pace running by a muscle-driven quadruped robot.
Typical rovers with wheels equipped with conventional grousers are prone to getting stuck in unconsolidated sandy dune inclines as the wheels tend to sink into the sand. This phenomenon is caused by the motion of the grouser through the sand during the latter half of the rotation, in which the grouser pushes the sand from underneath the wheel upwards and towards the backside of the wheel. This creates a space that the wheel can sink into. To minimize sand movement and subsequent sinkage, we propose the concept of using an “assistive grouser”, which is attached to the side of a conventional rover wheel. The assistive grouser is designed to be able to autonomously maintain a uniform angle relative to the rover body independent of the rotation of the wheels. Rotating the wheel causes the assistive grousers to automatically penetrate into the sand slope surface at a constant angle of attack, thereby acting as an anchor and providing traction for the wheel. Maintaining a uniform grouser angle as opposed to a rotating motion also assists in extracting the grouser out of the sand without moving the sand towards the back of the wheel. Moreover, the angle of the assistive grousers is held constantly by a single dedicated motor, meaning that the angle of the assistive grousers can be optimized to provide the least amount of sinkage for each slope angle. The experimental results showed that for slope angles of 0–30 degrees, the rover equipped with the proposed assistive grousers experienced significantly less sinkage and consumed less current compared to the rover equipped with conventional grousers.