Therese Bergh Nitter

Prof. Dr. Therese Bergh Nitter


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2022 in Building and Environment
Verified
Journal Article
Open access
MAM. Justo Alonso
M. Justo Alonso
TNTherese Bergh Nitter
Therese Bergh Nitter
PLP. Liu
P. Liu
RJRikke Bramming Jørgensen
Rikke Bramming Jørgensen
HMH.M. Mathisen
H.M. Mathisen
In this study, concentrations of pollutants: formaldehyde, carbon dioxide (CO2), and total volatile organic compounds (TVOC) and parameters: indoor room temperature and relative humidity (RH) were measured in 21 home offices for at least one week in winter in Trondheim, Norway. Eleven of these were measured again for the same duration in summer. Potentially explanatory variables of these parameters were collected, including building and renovation year, house type, building location, trickle vent status, occupancy, wood stove, floor material, pets, RH, and air temperature.

1 May 2019 in Science of The Total Environment
Verified
Journal Article
Open access
TNTherese Bergh Nitter
Therese Bergh Nitter
KSKristin V.H. Svendsen
Kristin V.H. Svendsen
Certain volatile disinfection by-products (DBPs) off-gassing from pool water can cause eye and skin irritations, respiratory problems, and even cancer. No guidelines or recommendations concerning DBPs in the air exist in Norway. Traditionally, ventilation strategies in indoor swimming pools are based on reducing condensation on the windows rather than ensuring proper air quality in the users' breathing zone. A total of 93 air samples of airborne concentrations of trihalomethanes (THMs) were collected via stationary sampling. We investigated the distribution of total THM (tTHM) 0.05 m and 0.60 m above the water surface at six different locations in the poolroom and the covariation between the water and air quality parameters. Based on a linear mixed effects model, the most important determinants in terms of predicting the air concentration of CHCl3 were height above water surface, air changes of fresh air per hour, concentration of combined chlorine in the water, relative humidity (RH) and day of the week. Approximately 36% of the total variability could be attributed to these variables; hence, to reduce the average exposure in the poolroom, hazard control should focus on these variables. Based on the identified predictor variables, the supplied air should be controlled based on water quality in addition to the traditional control censors for RH and air temperature used in the ventilation system of Norwegian swimming facilities.

23 May 2023 in Heliyon
Verified
Journal Article
Open access
TNTherese Bergh Nitter
Therese Bergh Nitter
KSKristin V Hirsch Svendsen
Kristin V Hirsch Svendsen
MBMorten Buhagen
Morten Buhagen
RJRikke Bramming Jørgensen
Rikke Bramming Jørgensen
Using an exposure chamber, we investigate the precision of the DustTrak DRX monitor by comparing its results to those obtained from taking traditional gravimetric samples of two stone minerals commonly used in asphalt and lactose powder. We also discuss the possibility of using real-time monitors such as DustTrak DRX for occupational exposure monitoring purposes.

1 June 2020 in Science of The Total Environment
Verified
Journal Article
Open access
TNTherese Bergh Nitter
Therese Bergh Nitter
KSKristin V. Hirsch Svendsen
Kristin V. Hirsch Svendsen
The association between asthma and exposure to the air in swimming facilities has been acknowledged. However, the variation in, long-term exposure to and management of the respiratory irritant trichloramine (NCl3) is not well understood. In this study, 313 swimmers above 18 years of age licensed by the Norwegian Swimming Association answered a questionnaire about health and swimming. The prevalence of asthma amongst the most-exposed swimmers was 36%. Two facilities, those with the highest and lowest reported prevalence of asthma, were chosen for further investigation. For each facility, a one-week-long monitoring campaign was performed, during which pool management, air and water quality were investigated. The results of this study showed that time of day, occupancy and pool management affect the concentration of NCl3, which ranged from 58 μg/m3 to 461 μg/m3. Furthermore, in one of the facilities, the concentration of CO2 was measured to evaluate whether this contaminant could be used to predict the number of pool occupants as well as the concentration of NCl3 in the air. The concentration of CO2 was significantly correlated with occupancy level (ρ = 0.82, p = 0.01) and NCl3 concentration (r = 0.80, p = 0.01). Furthermore, according to the random intercept model the concentration of CO2 explained 52% of the variation observed in the air concentration of NCl3. CO2 sensors to control the air supply can help reduce the air concentrations of NCl3 and balance the air supply based on occupancy level.

9 October 2017 in Water Supply
Verified
Journal Article
Closed access
PDF file
TNTherese Bergh Nitter
Therese Bergh Nitter
WKWolfgang Kampel
Wolfgang Kampel
KSKristin V. H. Svendsen
Kristin V. H. Svendsen
BABjørn Aas
Bjørn Aas
Certain aspects of the distribution of disinfection by-products (DBPs) in the air of indoor swimming pools, the exposure of the users, and possible health effects, have not been well documented. To determine the distribution of trihalomethanes (THMs), measurements were performed at 0.05 m, 0.60 m and 1.50 m above the water surface. These heights were chosen to measure the exposure in the breathing zone of the users. Air samples were collected from two indoor swimming pool facilities in Norway. Facility 1 uses calcium hypochlorite and facility 2 uses sodium hypochlorite for water treatment. In facility 2, one of the swimming pools is filled with 33% seawater, while the other pools in this study were filled with freshwater. Higher values were measured at 0.05 m compared to 1.50 m. Negligible differences between the measurements at 0.60 m and 1.50 m above floor levels were obtained. On average, 282% higher concentrations of total THM (tTHM) were measured in facility 2. Different disinfection products and ventilation concepts are possible explanations. Swimmers are exposed to higher concentrations compared to users by the poolside. For future studies, it is crucial to measure as close to the water surface as possible.

19 October 2023 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Open access
TNTherese Bergh Nitter
Therese Bergh Nitter
RJRikke Bramming Jørgensen
Rikke Bramming Jørgensen
KSKristin V Hirsch Svendsen
Kristin V Hirsch Svendsen
KTKrister Aune Teigen
Krister Aune Teigen
MHMarit Nøst Hegseth
Marit Nøst Hegseth
Exposure to polycyclic aromatic hydrocarbons (PAHs) of high molecular weight from chimney soot can cause cancer among chimney sweepers. These sweepers may also be exposed to high concentrations of nanosized particles, which can cause significant inflammatory responses due to their relatively greater surface area per mass. In this study, the authors aimed to assess the exposure profiles of airborne personal exposure to gaseous and particulate PAHs, and real-time samples of the particle number concentrations (PNCs), particle sizes, and lung-deposited surface areas (LDSAs), for chimney sweepers in Norway. Additionally, the authors aimed to assess the task-based exposure concentrations of PNCs, sizes, and LDSAs while working on different tasks. The results are based on personal samples of particulate PAHs (n = 68), gaseous PAHs (n = 28), and real-time nanoparticles (n = 8) collected from 17 chimney sweepers. Samples were collected during a "typical work week" of chimney sweeping and fire safety inspections, then during a "massive soot" week, where larger sweeping missions took place. Significantly higher PAH concentrations were measured during the "massive soot" week compared to the "typical work week," however, the time weighted average (TWA) (8-h) of all gaseous and particulate PAHs ranged from 0.52 to 4.47 µg/m3 and 0.49 - 2.50 µg/m3, respectively, well below the Norwegian occupational exposure limit (OEL) of 40 µg/m3. The PNCs were high during certain activities, such as emptying the vacuum cleaner. Additionally, during two days of sweeping in a waste sorting facility, the TWAs of the PNCs were 3.6 × 104 and 7.1 × 104 particles/cm3 on the first and second days, respectively, which were near and above the proposed nano reference limit TWA value of 4.0 × 104 particles/cm3 proposed by the International Workshop on Nano Reference Values. The corresponding TWAs of the LDSAs were 49.5 and 54.5 µm2/cm3, respectively. The chimney sweepers seemed aware of the potential health risks associated with exposure, and suitable personal protective equipment was used. However, the PNCs reported for the activities show that when the activities change or increase, the PNCs' TWAs can become unacceptably high.