This study investigated the exposure of cooks to polycyclic aromatic hydrocarbons (PAHs), higher mutagenic aldehydes, total particles, and ultrafine particles during cooking. Experiments were performed by pan frying fresh and smoked bacon on both electric and gas stoves, and with the gas alone. Detailed analyses of PAHs were performed, with analyses of the levels of 32 different PAHs. A TSI-3939 scanning mobility particle sizer system was used to measure the ultrafine particles. The results showed that total PAHs were in the range of 270–300 ng/m3 air. However, the smoked bacon experiment showed a somewhat different PAH pattern, whereby retene constituted about 10% of the total PAHs, which is a level similar to that of the abundant gas phase constituent phenanthrene. The reason for the elevated retene emissions is unknown. The total cancer risk, expressed as toxic equivalency factors, showed a somewhat higher risk on the electric stove (p < 0.05) compared with the gas stove. Levels of trans, trans-2,4-decadienal were between 34 and 54 μg/m3 air. The level of total particles was between 2.2 and 4.2 mg/m3. Frying on a gas stove caused a statistically significant higher amount of ultrafine particles compared with frying on an electric stove. Large variations in the mobility diameter at peak particle concentration were found (74.4 nm–153.5 nm). The highest mobility diameter was found for frying on an electric stove. The gas flame itself showed a maximum production of 19.5-nm-sized particles and could not be the explanation for the difference between frying on the gas stove and frying on the electric stove. No single indicator for the exposure to cooking fume could be selected. Each compound should be measured independently to provide a comprehensive characterization of the cooking exposure.
In this study, concentrations of pollutants: formaldehyde, carbon dioxide (CO2), and total volatile organic compounds (TVOC) and parameters: indoor room temperature and relative humidity (RH) were measured in 21 home offices for at least one week in winter in Trondheim, Norway. Eleven of these were measured again for the same duration in summer. Potentially explanatory variables of these parameters were collected, including building and renovation year, house type, building location, trickle vent status, occupancy, wood stove, floor material, pets, RH, and air temperature.
The aim of this study was to compare the applicability and the correlation between three commercially available instruments capable of detection, quantification, and characterization of ultrafine airborne particulate matter in the industrial setting of a tapping area in a silicon alloy production plant. The number concentration of ultrafine particles was evaluated using an Electric Low Pressure Impactor (ELPITM), a Fast Mobility Particle Sizer (FMPSTM), and a Condensation Particle Counter (CPC). The results are discussed in terms of particle size distribution and temporal variations linked to process operations. The instruments show excellent temporal covariation and the correlation between the FMPS and ELPI is good. The advantage of the FMPS is the excellent time- and size resolution of the results. The main advantage of the ELPI is the possibility to collect size-fractionated samples of the dust for subsequent analysis by, for example, electron microscopy. The CPC does not provide information about the particle size distribution and its correlation to the other two instruments is somewhat poor. Nonetheless, the CPC gives basic, real-time information about the ultrafine particle concentration and can therefore be used for source identification.
Using an exposure chamber, we investigate the precision of the DustTrak DRX monitor by comparing its results to those obtained from taking traditional gravimetric samples of two stone minerals commonly used in asphalt and lactose powder. We also discuss the possibility of using real-time monitors such as DustTrak DRX for occupational exposure monitoring purposes.
27 November 2019 in Journal of Occupational Medicine and Toxicology
Background: The aim of this study is to make a comparison of a new small sized nanoparticle monitoring instrument, Nanoscan SMPS, with more traditional large size instruments, known to be precise and accurate [Scanning Mobility Particle Sampler (SMPS) and Fast Mobility Particle Sizer (FMPS)], and with an older small size instrument with bulk measurements of 10–1000 nm particles (CPC3007). The comparisons are made during simulated exposure scenarios relevant to occupational hygiene studies. Methods: Four scenarios were investigated: metal inert gas (MIG) welding, polyvinyl chloride (PVC) welding, cooking, and candle-burning. Ratios between results are compaed and Pearsson correlations analysis was performed. Results: The highest correlation between the results is found between Nanoscan and SMPS, with Pearsson correlation coefficients above 0.9 for all scenarios. However, Nanoscan tended to overestimate the results from the SMPS; the ratio between the UFP concentrations vary between 1.44 and 2.01, and ratios of total concentrations between 1.18 and 2.33. CPC 3007 did not show comparable results with the remaining instruments. Conclusion: Based on the results of this study, the choice of measurement equipment may be crucial when evaluating measurement results against a reference value or a limit value for nanoparticle exposure. This stresses the need for method development, standardisation, and harmonisation of particle sampling protocols before reference values are introduced. Until this is established, the SMPS instruments are the most reliable for quantification of the concentrations of UFP, but in a more practical occupational hygiene context, the Nanoscan SMPS should be further tested.