Pablo Lenin Benitez Sellan

Dr. Pablo Lenin Benitez Sellan


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Journal of Dentistry
Verified
Journal Article
Closed access
CTCarlos Rocha Gomes Torres
Carlos Rocha Gomes Torres
MMMariane Cintra Mailart
Mariane Cintra Mailart
RRRafael Santos Rocha
Rafael Santos Rocha
PSPablo Lenin Benitez Sellan
Pablo Lenin Benitez Sellan
SCSheila Célia Mondragón Contreras
Sheila Célia Mondragón Contreras
Alexandre BorgesAlexandre Borges
Alexandre Borges

1 May 2020 in Heliyon
Verified
Journal Article
Open access
PSPablo Lenin Benitez Sellan
Pablo Lenin Benitez Sellan
RZRayssa Ferreira Zanatta
Rayssa Ferreira Zanatta
CTCarlos Rocha Gomes Torres
Carlos Rocha Gomes Torres
FTFu-Cong Tian
Fu-Cong Tian
BBBrian E. Bergeron
Brian E. Bergeron
CPCesar Rogerio Pucci
Cesar Rogerio Pucci
The present study examined a technique for reducing dentin permeability through the application of a calcium phosphate (CaP)-based desensitiser with a laser-assisted process and evaluated adhesive-dentin bond strength. Methods: Thirty dentin discs were divided into two groups according to whether the selected desensitiser (TeethMate; Kuraray Noritake) was used prior to dentin bonding. Each group was subdivided into three subgroups (n = 5): A- Adhesive (Single Bond Universal, 3M ESPE), AL- Adhesive + Laser (Nd:YAG 60 mJ) and LAL- Laser + Adhesive + Laser. Dentin permeability values (%) were recorded before and after desensitiser application. Resin composites were placed over the bonded specimens; the latter were aged prior to microtensile bond strength evaluation. Gelatinolytic activity within the hybrid layers was examined with in-situ zymography using confocal laser scanning microscopy. Data were analysed with ANOVA and Tukey test (α = 0.05). Significant differences in dentin permeability were identified for all groups (p = 0.00). Both laser treatment (p = 0.182) and desensitiser application (p = 0.687) did not significantly improve dentin bond strength. Ultrastructure of the resin-dentin interface identified presence of calcium phosphate within dentinal tubules. Laser treatment did not affect hybrid layer ultrastructure. Both treatment modalities (intratubular CaP occlusion and laser) had no influence on gelatinolytic activity within hybrid layers. Although intratubular CaP occlusion and laser treatment were effective in reducing dentin permeability, they did not affect bond strength, interfacial ultrastructure and gelatinolytic activity within hybrid layers. Treatment of etched dentin with Nd:YAG Laser at 60 mJ does not adversely affect collagen ultrastructure and gelatinolytic activity within the hybrid layer. The application of a calcium phosphate-based desensitiser to etch dentin does not affect dentin bond strength.

18 June 2019 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
PDF file
PSPablo Lenin Benitez Sellan
Pablo Lenin Benitez Sellan
EBEduardo Bresciani
Eduardo Bresciani

3 July 2023 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
Amjad Abu HasnaAmjad Abu Hasna
Amjad Abu Hasna
Frederico MartinhoFrederico Martinho
Frederico Martinho
PSPablo Lenin Benitez Sellan
Pablo Lenin Benitez Sellan
CPCamila Reis Pampuri
Camila Reis Pampuri
CTCarlos Rocha Gomes Torres
Carlos Rocha Gomes Torres
CPCesar Rogerio Pucci
Cesar Rogerio Pucci
This study aimed to evaluate Nd:YAG laser, calcium phosphate, and adhesive system effect as different pretreatments in different protocols on dentin permeability (DP) and bond strength (BS). Fifty human dentin discs were used (4 mm in diameter and 1,5 mm in height). Specimens were divided into five groups (n = 10): (A): adhesive system (control); (AL): adhesive system + Nd:YAG laser; (LAL): Nd:YAG laser + adhesive system + Nd:YAG laser; (PAL): calcium phosphate-based dentin desensitizer TeethMate + adhesive system + Nd:YAG laser; and group (PLAL): Nd:YAG laser + calcium phosphate-based dentin desensitizer + adhesive system + Nd:YAG laser. All materials were used according to the manufacturers’ instructions. The specimens were submitted to artificial aging (5,000 thermal cycles and 12 × 104 mechanical cycles) then a bond test was performed. DP was measured using the split chamber model. Data were submitted to one-way analysis of variance (ANOVA), paired t-test, RM ANOVA, and Tukey test ( ). All treatments were effective in DP reduction. For BS, the groups PAL and PLAL had improved BS with a statistically significant difference of the control group (A). Nd:Yag laser irradiation and calcium phosphate-based desensitizing agents significantly reduced DP, and the association between them could improve the BS on resin–human dentin interface.

20 June 2025 in Journal of Dental Education
Verified
Journal Article
Open access
PSPablo Lenin Benitez Sellan
Pablo Lenin Benitez Sellan
Edgar David GarcíaEdgar David García
Edgar David García
EBEduardo Bresciani
Eduardo Bresciani

28 August 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
PSPablo Lenin Benitez Sellan
Pablo Lenin Benitez Sellan
MRMaría Paula Sánchez Rogel
María Paula Sánchez Rogel
CBCoraima Pouleth Sandoval Bravo
Coraima Pouleth Sandoval Bravo
ALAntonio Lanata-Flores
Antonio Lanata-Flores
MBMarcelo Armijos Briones
Marcelo Armijos Briones
TGThiago Oliveira Gamba
Thiago Oliveira Gamba
Background/Objectives: Intraoral scanners (IOS) are increasingly integrated into dental curricula, yet evidence on how brief structured training affects novice students remains limited, particularly in resource-constrained settings. This pilot quasi-experimental study evaluated the effect of a structured IOS training program on the self-reported perceptions of undergraduate dental students with no prior IOS experience. Methods: Twenty first- and third-semester students at the School of Dentistry, Universidad de Especialidades Espíritu Santo (Ecuador), completed a 5-item Likert-type questionnaire (1–9 scale) before and after a training program comprising theoretical instruction and typodont-based practical sessions using a TRIOS 3 scanner (3Shape, Copenhagen, Denmark). Paired Student’s t-tests and Wilcoxon signed-rank tests were used to compare pre- and post-training scores, and effect sizes (Cohen’s d) were calculated for each dimension. Results: Significant improvements were observed in all five perception dimensions (all p < 0.001): familiarity (mean difference: +3.45; d = 1.74), comfort (+3.25; d = 1.91), confidence (+3.70; d = 2.06), perceived scan accuracy (+3.30; d = 1.61), and software competence (+3.55; d = 1.59). Conclusions: A brief, structured IOS training program produced large improvements in students’ self-reported perceptions. These findings support the early integration of IOS training into the dental curriculum. Future controlled studies should assess objective performance outcomes and long-term skill retention.