Potential under- or overdose of antibiotics may occur in intensive care units due to high variability in plasma concentrations. The risk is either treatment failure or toxicity. Thus, therapeutic drug monitoring of antibiotics may guide dosing adjustment, maximising antibacterial efficacy and minimising toxicity. The aim of this study was to develop and validate a method for the analysis of 15 antibiotics including beta-lactams, linezolid, fluoroquinolones, daptomycin, and clindamycin to have a complete panel in the management of infections. We proposed to develop a fast, sensitive, and quantitative method for the analysis of 15 antibiotics using ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometer (UPLC-MS/MS) technology. this method required only 100 µL of plasma and consisted of a rapid liquid–liquid deproteinisation using methanol. Calibration curves ranged from 0.078 to 500 mg/L depending on the molecules, and were defined according to a therapeutic range. Inter- and intra-assay precisions values were less than 15%. This work described the development and the full validation of a precise, sensitive and accurate assay using UPLC-MS/MS technology. After validation, this new assay was successfully applied to routine therapeutic drug monitoring.
Dihydropyrimidine dehydrogenase (DPD) deficiency is associated with severe fluoropyrimidines-induced toxicity. As of September 2018, French recommendations call for screening for DPD deficiency by plasma uracil quantification prior to all fluoropyrimidine-based chemotherapy. A dose reduction of fluoropyrimidine is recommended when uracil concentration is equal to or greater than 16 ng/mL. This matched retrospective study assessed the impact of DPD screening on the reduction of severe side effects and on the management of DPD-deficient patients. Using a propensity score, we balanced the factors influencing 5-Fluorouracil (5-FU) toxicity. Then, the severity scores (G3 and G4 severity as well as their frequency) of patients who did not benefit from DPD screening were compared with those of patients who benefited from DPD screening for each treatment cycle (from 1 to 4). Among 349 screened patients, 198 treated patients were included. Among them, 31 (15.7%) had DPD deficiency (median uracilemia 19.8 ng/mL (range: 16.1–172.3)). The median toxicity severity score was higher in the unscreened group for each treatment cycle (0 vs. 1, p < 0.001 at each cycle from 1 to 4) as well as the cumulative score during all courses of treatment (p = 0.028). DPD-deficient patients received a significantly lower dose of 5-FU (p < 0.001). This study suggests that pretherapeutic plasmatic uracil assessment, along with 5-FU dosage adjustment, may be beneficial in reducing 5-FU toxicity in real-life patients.
(1) Background: In toxicological laboratories, various screening methods can be used to identify compounds involved in intoxication. High-resolution mass spectrometry has been increasingly used in this context for the last years, because of its sensitivity and reliability. Here, we present the development and validation of a screening method that uses liquid chromatography coupled with a high-resolution mass spectrometer. (2) Methods: This method required only 100 µL of whole blood or plasma sample. Pretreatment consisted of a rapid and simple deproteinisation with methanol/acetonitrile and zinc sulphate. This new assay was validated according to international guidelines. (3) Results: To perform the method validation, 53 compounds were selected. The selection criteria were as follows: various chemical structures and therapeutic families (>15), large m/z distribution, positive or negative ionisation mode, and various elution times. The assays showed high selectivity and specificity, with optimal process efficiency. The identification limits, determined using predefined criteria, were established at sub-therapeutic or therapeutic concentrations. Applicability was evaluated using spiked plasma controls and external quality controls. (4) Conclusions: The new method was then successfully applied to routine clinical and forensic samples.
Objectives Non-adherence to rheumatoid arthritis (RA) treatments must be identified. A methotrexate (MTX) urinary dosage (METU) was recently developed. The aim of our study was to assess adherence to MTX in RA using METU in real-life conditions and to compare it with indirect adherence measurement technics. Methods We performed a cross-sectional study at Reims University Hospital. We included over 18-year-old patients with RA treated by MTX for more than 6 months. Patients were invited to complete demographic, clinical and psychological questionnaires and adherence measurement technics (Compliance Questionnaire of Rheumatology (CQR) and Medication Possession Ratio (MPR)). A urinary sample was collected to measure MTX and information about tolerance was evaluated through Methotrexate Intolerance Severity Score. Results 84 patients were included, 26 using oral MTX, 58 subcutaneous (SC) MTX. Among them, 73% were female, mean age was 61.5 years, MTX mean dose was 15 mg/week and 61.9% were treated by biological DMARDs (Disease Modifying Antirheumatic Drugs). 77 patients (91.7%) were adherent to treatment according to METU, whereas MPR and CQR reported less adherence (69.5% and 61.9%, respectively). MPR and METU were not significantly different in SC MTX users (p=0.059). Non-adherent patients had a higher number of tender joints and C reactive protein value (p<0.05). Conclusion This is the first largest study evaluating MTX adherence in patients with RA using a urinary dosage. We identified that indirect adherence measurements did not reflect real-life adherence. It would be appreciable to realise METU, in a new study, in patients with RA with unexplained response to treatment, to consider it before escalating therapeutic strategy.