Fast iterative soft threshold algorithm (FISTA) is one of the algorithms for the reconstruction part of compressed sensing (CS). However, FISTA cannot meet the increasing demands for accuracy and efficiency in the signal reconstruction. Thus, an improved algorithm (FIPITA, fast iterative parametric improved threshold algorithm) based on mended threshold function, restart adjustment mechanism and parameter adjustment is proposed. The three parameters used to generate the gradient in the FISTA are carefully selected by assessing the impact of them on the performance of the algorithm. The developed threshold function is used to replace the soft threshold function to reduce the reconstruction error and a restart mechanism is added at the end of each iteration to speed up the algorithm. The simulation experiment is carried out on one-dimensional signal and the FISTA, RadaFISTA and RestartFISTA are used as the comparison objects, with the result that in one case, for example, the residual rate of FIPITA is about 6.35% lower than those three and the number of iterations required to achieve the minimum error is also about 102 less than that of FISTA.
Adverse drug reactions (ADRs) are increasingly becoming a serious public health problem. Spontaneous reporting systems (SRSs) are an important way for many countries to monitor ADRs produced in the clinical use of drugs, and they are the main data source for ADR signal detection. The traditional signal detection methods are based on disproportionality analysis (DPA) and lack the application of data mining technology. In this paper, we selected the spontaneous reports from 2011 to 2018 in Jiangsu Province of China as the research data and used association rules analysis (ARA) to mine signals. We defined some important metrics of the ARA according to the two-dimensional contingency table of ADRs, such as Confidence and Lift, and constructed performance evaluation indicators such as Precision, Recall, and F1 as objective standards. We used experimental methods based on data to objectively determine the optimal thresholds of the corresponding metrics, which, in the best case, are Confidence = 0.007 and Lift = 1. We obtained the average performance of the method through 10-fold cross-validation. The experimental results showed that F1 increased from 31.43% in the MHRA method to 40.38% in the ARA method; this was a significant improvement. To reduce drug risk and provide decision making for drug safety, more data mining methods need to be introduced and applied to ADR signal detection.