Peter Jevnikar

Prof. Dr. Peter Jevnikar

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2010 in Dental Materials
Verified
Journal Article
Closed access
PJPeter Jevnikar
Peter Jevnikar
KKKristoffer Krnel
Kristoffer Krnel
Andraž KocjanAndraž Kocjan
Andraž Kocjan
NFNenad Funduk
Nenad Funduk
TKTomaž Kosmač
Tomaž Kosmač

1 April 2018 in Journal of Prosthodontic Research
Verified
Journal Article
Closed access
MAMaja Antanasova
Maja Antanasova
AKAndraž Kocjan
Andraž Kocjan
JKJanez Kovač
Janez Kovač
BŽBorut Žužek
Borut Žužek
PJPeter Jevnikar
Peter Jevnikar
The aim has been to determine the effect of thermo-mechanical cycling on shear-bond-strength (SBS) of dental porcelain to Co-Cr and Ti-based alloys fabricated by casting, computer-numerical-controlled milling, and selective-laser-melting (SLM). Seven groups (n=22/group) of metal cylinders were fabricated by casting (Co-Cr and commercially pure-cpTi), milling (Co-Cr, cpTi, Ti-6Al-4V) or by SLM (Co-Cr and Ti-6Al-4V) and abraded with airborne-particles. The average surface roughness (Ra) was determined for each group. Dental porcelain was applied and each metal-ceramic combination was divided into two subgroups - stored in deionized water (24-h, 37°C), or subjected to both thermal (6000-cycles, between 5 and 60°C) and mechanical cycling (105-cycles, 60N-load). SBS test-values and failure modes were recorded. Metal-ceramic interfaces were analyzed with a focused-ion-beam/scanning-electron-microscope (FIB/SEM) and energy-dispersive-spectroscopy (EDS). The elastic properties of the respective metal and ceramic materials were evaluated by instrumented-indentation-testing. The oxide thickness on intact Ti-based substrates was measured with Auger-electron-spectroscopy (AES). Data were analyzed using ANOVA, Tukey's HSD and t-tests (α=0.05). The SBS-means differed according to the metal-ceramic combination (p<0.0005) and to the fatigue conditions (p<0.0005). The failure modes and interface analyses suggest better porcelain adherence to Co-Cr than to Ti-based alloys. Values of Ra were dependent on the metal substrate (p<0.0005). Ti-based substrates were not covered with thick oxide layers following digital fabrication. Ti-based alloys are more susceptible than Co-Cr to reduction of porcelain bond strength following thermo-mechanical cycling. The porcelain bond strength to Ti-based alloys is affected by the applied metal processing technology.

1 March 2021 in Dental Materials
Verified
Journal Article
Closed access
AKAndraž Kocjan
Andraž Kocjan
JCJasna Cotič
Jasna Cotič
TKTomaž Kosmač
Tomaž Kosmač
PJPeter Jevnikar
Peter Jevnikar

1 March 2020 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
MAMaja Antanasova
Maja Antanasova
AKAndraž Kocjan
Andraž Kocjan
MHMatej Hočevar
Matej Hočevar
PJPeter Jevnikar
Peter Jevnikar

1 March 2021 in Dental Materials
Verified
Journal Article
Closed access
JCJasna Cotič
Jasna Cotič
AKAndraž Kocjan
Andraž Kocjan
SPSanja Panchevska
Sanja Panchevska
TKTomaž Kosmač
Tomaž Kosmač
PJPeter Jevnikar
Peter Jevnikar

7 February 2016 in Radiology and Oncology
Verified
Journal Article
Open access
PDF file
JCJasna Cotic
Jasna Cotic
JJJure Jamsek
Jure Jamsek
MKMilan Kuhar
Milan Kuhar
NHNatasa Ihan Hren
Natasa Ihan Hren
AKAndrej Kansky
Andrej Kansky
PJPeter Jevnikar
Peter Jevnikar
Background: Slovenia has a high burden of head and neck cancer. Patients are mostly treated with surgery followed by radiation therapy. Advanced surgical and prosthodontic techniques have expanded the rehabilitation options. The aim of the study was to review the outcome of implant-prosthetic treatment after radiation therapy.Patients and methods: Twenty irradiated head and neck cancer patients who received a removable implant-supported denture at the University Medical Centre Ljubljana were included in the study. Kaplan-Meier survival analysis, Cox proportional hazard models and logistic regression were used to assess the implant survival and success rate.Results: Twenty patients had 100 implants inserted. The estimated implant survival rate was 96% after 1 year and 87% after 5 years. Failures were mostly observed before loading (91.2%). Implants inserted in the transplanted bone were significantly more likely to fail. Out of 89 implants supporting the dentures, 79 implants (88.7%) were successful, meaning that they were functionally loaded and exhibited no pain, radiolucency or progressive bone loss. Prosthetic treatment was significantly less successful in older patients. The attachment system and the number of implants did not have a statistically significant influence on the success rate.Conclusions: Implant-supported dentures have been shown to be a reliable treatment modality after head and neck cancer surgery and radiation therapy. Possible early failures should be communicated with the patients.