Tongjun Bu

Mr. Tongjun Bu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
THTongyu Huang
Tongyu Huang
RMRuoyu Meng
Ruoyu Meng
JSJiawei Song
Jiawei Song
TBTongjun Bu
Tongjun Bu
YZYuanhuan Zhu
Yuanhuan Zhu
Hui MaHui Ma
Hui Ma
Polarization imaging techniques are sensitive to the anisotropic microstructure of samples, therefore can be regarded as a potential tool in biomedical studies. Mueller matrix (MM) provides the comprehensive characterization of sample’s polarization properties. When considering the polarization detection for bulk biological tissues such as living organs, backscattering MM imaging is more applicable. In recent years, many applications of backscattering MM imaging in biomedical fields have emerged, including endoscopy,1 – 4 cancer diagnosis,5 urology pathology detection,6 and characterization of tissue optical clearing (TOC).7 Compared to the oblique incident illumination reflection MM imaging system,8 collinear reflection MM imaging can obtain a set of rotation invariant parameters which are not affected by the sample’s azimuth angles,9,10 and is therefore particularly suitable for probing the intrinsic polarization properties of the anisotropic samples. For polarization monitoring on living animals or dynamic processes, higher measurement speed and accuracy are always in demand.

5 March 2024 in Photonics
Verified
Journal Article
Open access
PDF file
QLQizhi Lai
Qizhi Lai
TBTongjun Bu
Tongjun Bu
THTongyu Huang
Tongyu Huang
YSYanan Sun
Yanan Sun
YWYi Wang
Yi Wang
Hui MaHui Ma
Hui Ma
Polarization imaging is a label-free and non-invasive technique that is sensitive to microstructure and suitable for probing the microstructure of living tissues. However, obtaining deep-layer information from tissues has been a challenge for optical techniques. In this work, we used tissue optical clearing (TOC) to increase optical penetration depth and characterize the layered structures of tissue samples. Different tissue phantoms were constructed to examine changes in the polarization features of the layered structure during the TOC process. We found that depolarization and anisotropy parameters were able to distinguish between single-layer and double-layer phantoms, reflecting microstructural information from each layer. We observed changes in polarization parameter images during the TOC process and, by analyzing different regions of the images, explained the sensitivity of these parameters to double-layer structures and analyzed the influence of oblique incident illumination. Finally, we conducted TOC experiments on living skin samples, leveraging the experience gained from phantom experiments to identify the double-layer structure of the skin and extract features related to layered structures. The results show that the combination of backscattering polarization imaging and tissue optical clearing provides a powerful tool for the characterization of layered samples.

4 March 2022 in Photonics
Verified
Journal Article
Open access
PDF file
TBTongjun Bu
Tongjun Bu
CSConghui Shao
Conghui Shao
YZYuanhuan Zhu
Yuanhuan Zhu
THTongyu Huang
Tongyu Huang
QZQianhao Zhao
Qianhao Zhao
Hui MaHui Ma
Hui Ma
Polarization imaging can quantitatively probe the microscopic structure of biological tissues which can be complex and consist of layered structures. In this paper, we established a fast-backscattering Mueller matrix imaging system to characterize the dynamic variation in the microstructure of single-layer and double-layer tissues as glycerin solution penetrated into the samples. The characteristic response of Mueller matrix elements, as well as polarization parameters with clearer physics meanings, show that polarization imaging can capture the dynamic variation in the layered microstructure. The experimental results are confirmed by Monte Carlo simulations. Further examination on the accuracy of Mueller matrix measurements also shows that much faster speed has to be considered when backscattering Mueller matrix imaging is applied to living samples.