Tongyu Huang

Dr. Tongyu Huang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
THTongyu Huang
Tongyu Huang
RMRuoyu Meng
Ruoyu Meng
JSJiawei Song
Jiawei Song
TBTongjun Bu
Tongjun Bu
YZYuanhuan Zhu
Yuanhuan Zhu
Hui MaHui Ma
Hui Ma
Polarization imaging techniques are sensitive to the anisotropic microstructure of samples, therefore can be regarded as a potential tool in biomedical studies. Mueller matrix (MM) provides the comprehensive characterization of sample’s polarization properties. When considering the polarization detection for bulk biological tissues such as living organs, backscattering MM imaging is more applicable. In recent years, many applications of backscattering MM imaging in biomedical fields have emerged, including endoscopy,1 – 4 cancer diagnosis,5 urology pathology detection,6 and characterization of tissue optical clearing (TOC).7 Compared to the oblique incident illumination reflection MM imaging system,8 collinear reflection MM imaging can obtain a set of rotation invariant parameters which are not affected by the sample’s azimuth angles,9,10 and is therefore particularly suitable for probing the intrinsic polarization properties of the anisotropic samples. For polarization monitoring on living animals or dynamic processes, higher measurement speed and accuracy are always in demand.

5 March 2024 in Photonics
Verified
Journal Article
Open access
PDF file
QLQizhi Lai
Qizhi Lai
TBTongjun Bu
Tongjun Bu
THTongyu Huang
Tongyu Huang
YSYanan Sun
Yanan Sun
YWYi Wang
Yi Wang
Hui MaHui Ma
Hui Ma
Polarization imaging is a label-free and non-invasive technique that is sensitive to microstructure and suitable for probing the microstructure of living tissues. However, obtaining deep-layer information from tissues has been a challenge for optical techniques. In this work, we used tissue optical clearing (TOC) to increase optical penetration depth and characterize the layered structures of tissue samples. Different tissue phantoms were constructed to examine changes in the polarization features of the layered structure during the TOC process. We found that depolarization and anisotropy parameters were able to distinguish between single-layer and double-layer phantoms, reflecting microstructural information from each layer. We observed changes in polarization parameter images during the TOC process and, by analyzing different regions of the images, explained the sensitivity of these parameters to double-layer structures and analyzed the influence of oblique incident illumination. Finally, we conducted TOC experiments on living skin samples, leveraging the experience gained from phantom experiments to identify the double-layer structure of the skin and extract features related to layered structures. The results show that the combination of backscattering polarization imaging and tissue optical clearing provides a powerful tool for the characterization of layered samples.

10 May 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
YCYan Chen
Yan Chen
HWHongjian Wang
Hongjian Wang
RLRan Liao
Ran Liao
HLHening Li
Hening Li
YWYihao Wang
Yihao Wang
Hui MaHui Ma
Hui Ma
Suspended particles play a vital role in aquatic environments. We propose a method to rapidly measure the scattered polarization parameters of individual suspended particles with continuously large angular range (PCLAR), from 60° to 120° in one shot. A conceptual setup is built to measure PCLAR with 20 kHz; to verify the setup, 10 μm-diameter silica microspheres suspended in water, whose PCLAR are consistent with those simulated by Mie theory, are measured. PCLAR of 6 categories of particles are measured, which enables high-accuracy classification with the help of a convolutional neural network algorithm. PCLAR of different mixtures of Cyclotella stelligera and silica microspheres are measured to successfully identify particulate components. Furthermore, classification ability comparisons of different angular-selection strategies show that PCLAR enables the best classification beyond the single angle, discrete angles and small-ranged angles. Simulated PCLAR of particles with different size, refractive index, and structure show explicit discriminations between them. Inversely, the measured PCLAR are able to estimate the effective size and refractive index of individual Cyclotella cells. Results demonstrate the method’s power, which intrinsically takes the advantage of the optical polarization and the angular coverage. Future prototypes based on this concept would be a promising biosensor for particles in environmental monitoring.

1 October 2023 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
SWShilong Wei
Shilong Wei
LSLu Si
Lu Si
THTongyu Huang
Tongyu Huang
SDShan Du
Shan Du
YYYue Yao
Yue Yao
Hui MaHui Ma
Hui Ma
SignificanceMueller matrix (MM) microscopy has proven to be a powerful tool for probing microstructural characteristics of biological samples down to subwavelength scale. However, in clinical practice, doctors usually rely on bright-field microscopy images of stained tissue slides to identify characteristic features of specific diseases and make accurate diagnosis. Cross-modality translation based on polarization imaging helps to improve the efficiency and stability in analyzing sample properties from different modalities for pathologists.AimIn this work, we propose a computational image translation technique based on deep learning to enable bright-field microscopy contrast using snapshot Stokes images of stained pathological tissue slides. Taking Stokes images as input instead of MM images allows the translated bright-field images to be unaffected by variations of light source and samples.ApproachWe adopted CycleGAN as the translation model to avoid requirements on co-registered image pairs in the training. This method can generate images that are equivalent to the bright-field images with different staining styles on the same region.ResultsPathological slices of liver and breast tissues with hematoxylin and eosin staining and lung tissues with two types of immunohistochemistry staining, i.e., thyroid transcription factor-1 and Ki-67, were used to demonstrate the effectiveness of our method. The output results were evaluated by four image quality assessment methods.ConclusionsBy comparing the cross-modality translation performance with MM images, we found that the Stokes images, with the advantages of faster acquisition and independence from light intensity and image registration, can be well translated to bright-field images.

4 March 2022 in Photonics
Verified
Journal Article
Open access
PDF file
TBTongjun Bu
Tongjun Bu
CSConghui Shao
Conghui Shao
YZYuanhuan Zhu
Yuanhuan Zhu
THTongyu Huang
Tongyu Huang
QZQianhao Zhao
Qianhao Zhao
Hui MaHui Ma
Hui Ma
Polarization imaging can quantitatively probe the microscopic structure of biological tissues which can be complex and consist of layered structures. In this paper, we established a fast-backscattering Mueller matrix imaging system to characterize the dynamic variation in the microstructure of single-layer and double-layer tissues as glycerin solution penetrated into the samples. The characteristic response of Mueller matrix elements, as well as polarization parameters with clearer physics meanings, show that polarization imaging can capture the dynamic variation in the layered microstructure. The experimental results are confirmed by Monte Carlo simulations. Further examination on the accuracy of Mueller matrix measurements also shows that much faster speed has to be considered when backscattering Mueller matrix imaging is applied to living samples.