Ultrasound based on-line cleaning for membrane filtration of industrial wastewater was studied. An ultrasonic transducer was assembled in the membrane module in order to get an efficient cleaning of membranes in fouling conditions. The focus of the studies was on the effects of the ultrasound propagation direction and frequency as well as the transmembrane pressure. The more open the membrane was the easier the membrane became plugged by wastewater colloids, when the ultrasound propagation direction was from the feed flow side of the membrane. If the membrane was tight enough, the ultrasound irradiated from the feed side of the membrane increased the flux significantly. However, in the circumstances studied, the power intensity needed during filtration was so high that the membranes eroded gradually at some spots of the membrane surface. It was discovered that the ultrasonic field produced by the used transducers was uneven in pressurised conditions. On the other hand, the ultrasound treatment at atmospheric pressure during an intermission pause in filtration turned out to be an efficient and, at the same time, a gentle method in membrane cleaning. The input power of 120 W (power intensity of 1.1 W/cm2) for a few seconds was sufficient for cleaning. The flux improvement was significant when using a frequency of 27 kHz but only minor when using 200 kHz.
Water reuse from wastewater treatment plants can significantly reduce freshwater demand. Additionally municipal sewage and some industrial wastewaters could be used as sources of nutrients and carbon more effectively than they are used today. Biological treatments have attracted the most attention in wastewater purification, whereas, so far, only a little attention has been paid to the physico-chemical technologies. These technologies could, however, have great potential to recover nutrients when purifying wastewater. In this study, the main emphasis was to study the possibilities to utilize existing physico-chemical unit operations for wastewater purification and nutrients as well as carbon recovery. Unit operations were selected so that they could produce exploitable circular economy products from wastewaters and be assembled in a mobile container for carrying out recovery anywhere that is suitable. The results showed that in a mobile container, solids could be successfully separated from the studied wastewaters by flocculation-assisted solid/liquid separation and then processed into hydrochar by hydrothermal carbonization. Phosphate was precipitated using lime milk as calcium phosphate, and ammonium nitrogen was captured from the wastewater using membrane contactor technology resulting in ammonium sulphate for fertilizer use. Additionally, reverse osmosis retained residual impurities well, producing good quality water for reuse. The techno-economic feasibility seems promising.
Intense pressure on water resources has led to efforts to reuse reclaimed processing wastewater in the food industry. There are tight rules for water quality, but efficient separation technologies such as reverse osmosis possess good possibilities for water reuse. This study developed a membrane-based reuse water concept for wastewater from the candy industry emphasizing the pre-treatment stage in the concept to reduce fouling. The wastewater contained suspended solids, sugar compounds and the ingredients for candy gelation, which had a tendency to foul membranes, making pre-treatment essential for a successful concept. Cross-rotational ultrafiltration, which featured enhanced fouling prevention for membranes, functioned well for the removal of challenging substances. Conventional filtration technologies were impractical due to a low flux, even when the viscosity of the wastewater was reduced using surfactants. The wastewater had a high chemical oxygen demand, meaning that there was a strong fouling potential for reverse osmosis membranes, but also high osmotic pressure. A spiral wound reverse osmosis functioned well when the wastewater was pre-treated, and it produced good quality water with respect to all the other studied parameters except the chemical oxygen demand. However, chemical oxygen demand rejection was 99% since the concentration in the wastewater was originally very high.
Large amounts of wet sludge are produced annually in municipal and industrial wastewater treatment. Already in pulp and paper industry, more than ten million tons of primary sludge, waste activated sludge, and de-inking sludge is generated. Waste activated sludge contains large quantities of bound water, which is difficult to dewater. Low water content would be a matter of high calorific value in incineration but it also has effects on the volume and the quality of the matter to be handled in sludge disposal. In this research waste activated sludges from different pulp and paper mills were chemically characterised and dewatered. Correlations of chemical composition and dewatering properties were determined using multivariate analysis. Chemical characterisation included basic sludge analysis, elementary analysis and analysis of wood-based components, such as hemicelluloses and lignin-derived material. Dewatering properties were determined using measurements of dry solids content, flux and flocculant dosage. The effects of different variables varied according to the response concerned. The variables which were significant regarding cake DS increase in filtration or centrifugation and flocculant dosage needed in filtration were different from those which were significant regarding flux.