A pressure pulsation experiment of a dishwasher pump with a passive rotation double-tongue volute was carried out and compared with the pressure pulsation of a single-tongue volute and a static double-tongue volute. The pressure pulsation of the three volute models was compared and analyzed from two aspects of different impeller speeds and different monitoring points. The frequency domain and time–frequency domain of pressure pulsation were obtained by a Fourier transform and short-time Fourier transform, respectively. The results showed that the average pressure of each monitoring point on the rotating double-tongue volute was the smallest and that on the single-tongue volute was the largest. When the impeller rotates at 3000 rpm, there were eight peaks and valleys in the pressure pulsation time domain curve of the single-tongue volute, while the double-tongue volute was twice that of the single-tongue volute. Under different impeller speeds, the changing trends of pressure pulsation time and frequency domain curves of static and rotating double-tongue volutes at monitoring point p1 are basically the same. Therefore, a volute reference scheme with passive rotation speed is proposed in this study, which can effectively improve the flow pattern and reduce pressure inside the dishwasher pump, and also provide a new idea for rotor–rotor interference to guide the innovation of dishwashers.
Through numerical simulations, this work analyzes the unsteady pressure pulsation characteristics in new type of dishwasher pump with double tongue volute and single tongue volute, under volute static and rotation conditions. Likewise, the performance tests were also carried out to verify the numerical results. Multiple monitoring points were set at the various positions of new type dishwasher pump to collect the pressure pulsation signals, and the relevant frequency signals were obtained via Fast Fourier Transform, to analyze the influence of volute tongue and its passive speed on the pump performance. The results reveal that when the double tongue volute is stationary, the pressure pulsation amplitudes increase from the impeller inlet to the impeller outlet. Under the influence of shedding vortex, the pressure pulsation in the lateral region of tongue becomes disorganized, and the main frequency of pressure pulsation changes from blade frequency to shaft frequency. In addition, compared with the static volute, double tongue volute can effectively guide the water flow out of the tongue during the rotation process, thus ensuring good periodicity for pressure pulsation in the tongue region. Accordingly, a volute reference scheme with passive rotation speed is proposed in this study, which can effectively improve the pressure pulsation at tongue position, and provides a new idea for rotor-stator interference to guide the innovation of dishwasher.