David Sailor

Dr. David Sailor

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Urban Forestry & Urban Greening
Verified
Journal Article
Closed access
QZQunshan Zhao
Qunshan Zhao
DSDavid Sailor
David Sailor
EWElizabeth A. Wentz
Elizabeth A. Wentz

1 May 2021 in Environmental Research Letters
Verified
Journal Article
Open access
PDF file
EKEric Scott Krayenhoff
Eric Scott Krayenhoff
ABAshley M. Broadbent
Ashley M. Broadbent
LZLei Zhao
Lei Zhao
MGMatei Georgescu
Matei Georgescu
AMAriane Middel
Ariane Middel
EEEvyatar Erell
Evyatar Erell
Infrastructure-based heat reduction strategies can help cities adapt to high temperatures, but simulations of their cooling potential yield widely varying predictions. We systematically review 146 studies from 1987 to 2017 that conduct physically based numerical modelling of urban air temperature reduction resulting from green-blue infrastructure and reflective materials. Studies are grouped into two modelling scales: neighbourhood scale, building-resolving (i.e. microscale); and city scale, neighbourhood-resolving (i.e. mesoscale). Street tree cooling has primarily been assessed at the microscale, whereas mesoscale modelling has favoured reflective roof treatments, which are attributed to model physics limitations at each scale. We develop 25 criteria to assess contextualization and reliability of each study based on metadata reporting and methodological quality, respectively. Studies have shortcomings with respect to neighbourhood characterization, reporting areal coverages of heat mitigation implementations, evaluation of base case simulations, and evaluation of modelled physical processes relevant to heat reduction. To aid comparison among studies, we introduce two metrics: the albedo cooling effectiveness (ACE), and the vegetation cooling effectiveness (VCE). A sub-sample of 47 higher quality studies suggests that high reflectivity coatings or materials offer ≈0.2 °C–0.6 °C cooling per 0.10 neighbourhood albedo increase, and that trees yield ≈0.3 °C cooling per 0.10 canopy cover increase, for afternoon clear-sky summer conditions. VCE of low vegetation and green roofs varies more strongly between studies. Both ACE and VCE exhibit a striking dependence on model choice and model scale, particularly for albedo and roof-level implementations, suggesting that much of the variation of cooling magnitudes between studies may be attributed to model physics representation. We conclude that evaluation of the base case simulation is not a sufficient prerequisite for accurate simulation of heat mitigation strategy cooling. We identify a three-phase framework for assessment of the suitability of a numerical model for a heat mitigation experiment, which emphasizes assessment of urban canopy layer mixing and of the physical processes associated with the heat reduction implementation. Based on our findings, we include recommendations for optimal design and communication of urban heat mitigation simulation studies.

1 December 2018 in Urban Climate
Verified
Journal Article
Closed access
PCPeter Crank
Peter Crank
DSDavid Sailor
David Sailor
GBGeorge Ban-Weiss
George Ban-Weiss
MTMohammad Taleghani
Mohammad Taleghani

1 December 2021 in Energy and Buildings
Verified
Journal Article
Open access
DSDavid Sailor
David Sailor
JAJ. Anand
J. Anand
RKR.R. King
R.R. King

1 March 2014 in Building and Environment
Verified
Journal Article
Closed access
MTMohammad Taleghani
Mohammad Taleghani
DSDavid Sailor
David Sailor
MTMartin Tenpierik
Martin Tenpierik
ADAndy van Den Dobbelsteen
Andy van Den Dobbelsteen

1 October 2015 in Atmospheric Environment
Verified
Journal Article
Open access
DSDavid Sailor
David Sailor
MGMatei Georgescu
Matei Georgescu
JMJeffrey M. Milne
Jeffrey M. Milne
MHMelissa A. Hart
Melissa A. Hart
Given increasing utility of numerical models to examine urban impacts on meteorology and climate, there exists an urgent need for accurate representation of seasonally and diurnally varying anthropogenic heating data, an important component of the urban energy budget for cities across the world. Incorporation of anthropogenic heating data as inputs to existing climate modeling systems has direct societal implications ranging from improved prediction of energy demand to health assessment, but such data are lacking for most cities. To address this deficiency we have applied a standardized procedure to develop a national database of seasonally and diurnally varying anthropogenic heating profiles for 61 of the largest cities in the United Stated (U.S.). Recognizing the importance of spatial scale, the anthropogenic heating database developed includes the city scale and the accompanying greater metropolitan area. Our analysis reveals that a single profile function can adequately represent anthropogenic heating during summer but two profile functions are required in winter, one for warm climate cities and another for cold climate cities. On average, although anthropogenic heating is 40% larger in winter than summer, the electricity sector contribution peaks during summer and is smallest in winter. Because such data are similarly required for international cities where urban climate assessments are also ongoing, we have made a simple adjustment accounting for different international energy consumption rates relative to the U.S. to generate seasonally and diurnally varying anthropogenic heating profiles for a range of global cities. The methodological approach presented here is flexible and straightforwardly applicable to cities not modeled because of presently unavailable data. Because of the anticipated increase in global urban populations for many decades to come, characterizing this fundamental aspect of the urban environment – anthropogenic heating – is an essential element toward continued progress in urban climate assessment