Salvador López-Gil

Dr. Salvador López-Gil

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2023 in Kidney360
Verified
Journal Article
Open access
AAArmando Armenta-Alvarez
Armando Armenta-Alvarez
SLSalvador López-Gil
Salvador López-Gil
IOIván Osuna
Iván Osuna
NGNadja Grobe
Nadja Grobe
XTXia Tao
Xia Tao
MMMagdalena Madero
Magdalena Madero
Key Points: HDF and MCO have shown greater clearance of middle-size uremic solutes in comparison with HF dialyzers; MCO has never been studied in HDF. MCO in HDF does not increase the clearance of B2M and results in a higher loss of albumin. Background: Middle molecule removal and albumin loss have been studied in medium cutoff (MCO) membranes on hemodialysis (HD). It is unknown whether hemodiafiltration (HDF) with MCO membranes provides additional benefit. We aimed to compare the removal of small solutes and β2-microglobulin (B2M), albumin, and total proteins between MCO and high-flux (HFX) membranes with both HD and HDF, respectively. Methods: The cross-over study comprised 4 weeks, one each with postdilutional HDF using HFX (HFX-HDF), MCO (MCO-HDF), HD with HFX (HFX-HD), and MCO (MCO-HD). MCO and HFX differ with respect to several characteristics, including membrane composition, pore size distribution, and surface area (HFX, 2.5 m2; MCO, 1.7 m2). There were two study treatments per week, one after the long interdialytic interval and another midweek. Reduction ratios of vitamin B12, B2M, phosphate, uric acid, and urea corrected for hemoconcentration were computed. Dialysis albumin and total protein loss during the treatment were quantified from dialysate samples. Results: Twelve anuric patients were studied (six female patients; 44±19 years; dialysis vintage 35.2±28 months). The blood flow was 369±23 ml/min, dialysate flow was 495±61 ml/min, and ultrafiltration volume was 2.8±0.74 L. No significant differences were found regarding the removal of B2M, vitamin B12, and water-soluble solutes between dialytic modalities and dialyzers. Albumin and total protein loss were significantly higher in MCO groups than HFX groups when compared with the same modality. HDF groups had significantly higher albumin and total protein loss than HD groups when compared with the same dialyzer. MCO-HDF showed the highest protein loss among all groups. Conclusions: MCO-HD is not superior to HFX-HD and HFX-HDF for both middle molecule and water-soluble solute removal. Protein loss was more pronounced with MCO when compared with HFX on both HD and HDF modalities. MCO-HDF has no additional benefits regarding better removal of B2M but resulted in greater protein loss than MCO-HD.

27 January 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
VJVictor Hugo Gomez Johnson
Victor Hugo Gomez Johnson
SLSalvador López-Gil
Salvador López-Gil
EAEduardo Argaiz
Eduardo Argaiz
Abhilash KoratalaAbhilash Koratala
Abhilash Koratala
Point-of-care ultrasound (POCUS) has increasingly become an integral part of clinical practice, particularly in nephrology, where its use extends beyond renal assessment to include multi-organ evaluations. Despite challenges such as limited ultrasound training and equipment access, especially in low- and middle-income countries, the adoption of POCUS is steadily rising. This narrative review explores the growing role of multi-organ POCUS in nephrology, with applications ranging from the assessment of congestion phenotypes, cardiorenal syndrome, and hemodynamic acute kidney injury (AKI) to the evaluation of arteriovenous fistulas and electrolyte disorders. In nephrology, POCUS enhances clinical decision making by enabling rapid, bedside evaluations of fluid status, cardiac function, and arteriovenous access. Studies have demonstrated its utility in diagnosing and managing complications such as heart failure, cirrhosis, and volume overload in end-stage renal disease. Additionally, POCUS has proven valuable in assessing hemodynamic alterations that contribute to AKI, particularly in patients with heart failure, cirrhosis, and systemic congestion. This review highlights how integrating ultrasound techniques, including lung ultrasound, venous Doppler, and focused cardiac ultrasound, can guide fluid management and improve patient outcomes. With advancements in ultrasound technology, particularly affordable handheld devices, and the expansion of targeted training programs, the potential for POCUS to become a global standard tool in nephrology continues to grow, enabling improved care in diverse clinical settings.

23 December 2021 in Biology
Verified
Journal Article
Open access
PDF file
Claudia LermaClaudia Lerma
Claudia Lerma
NSNadia Saavedra-Fuentes
Nadia Saavedra-Fuentes
JLJasbeth Ledesma-Gil
Jasbeth Ledesma-Gil
MJMartín Calderón Juárez
Martín Calderón Juárez
HPHector Perez-Grovas
Hector Perez-Grovas
SLSalvador López-Gil
Salvador López-Gil
Ocular complications are common among end-stage renal disease patients and some complications had been linked to increments of intraocular pressure (IOP) during hemodialysis. The changes of IOP during hemodiafiltration (HDF) have been scarcely investigated and the potential influence of the sodium dialysate concentration is unknown. The aim of this study was to compare the IOP changes during HDF with sodium dialysate concentration, either fixed or individualized. Thirteen end-stage renal disease patients participated in the study; they were treated with HDF using a dialysate sodium profile fixed at 138 mmol and another session with an individualized sodium profile. The intraocular pressure was measured before and after each session and every 30 min during HDF. Both groups had a similar HDF prescription, blood pressure, and biochemical parameters. At the end of hemodiafiltration, sodium concentration decreased only in the fixed sodium profile group. The number of patients with at least an episode of intraocular hypertension during HDF ranged from 5 (19%) to 8 (31%) without significant differences between right and left eye nor between dialysate sodium concentration. During HDF, there is a large variability of IOP; transient events of intraocular hypertension are highly prevalent in this sample, and they are not related to the sodium dialysate concentration.

23 May 2026 in Archives of Medical Research
Verified
Journal Article
Closed access
LCLaura Crespo-Ortega
Laura Crespo-Ortega
RVRodrigo Villaseñor-Echavarri
Rodrigo Villaseñor-Echavarri
VLValeria Liberman-Borovoy
Valeria Liberman-Borovoy
LRLaura Rincon-Ángel
Laura Rincon-Ángel
SLSalvador López-Gil
Salvador López-Gil

25 March 2024 in World Journal of Nephrology
Verified
Journal Article
Open access
JJJose Daniel Juarez-Villa
Jose Daniel Juarez-Villa
IZIván Zepeda-Quiroz
Iván Zepeda-Quiroz
STSebastián Toledo-Ramírez
Sebastián Toledo-Ramírez
VGVictor Hugo Gomez-Johnson
Victor Hugo Gomez-Johnson
FPFrancisco Pérez-Allende
Francisco Pérez-Allende
SLSalvador López-Gil
Salvador López-Gil
BACKGROUND The association between congenital heart disease and chronic kidney disease is well known. Various mechanisms of kidney damage associated with congenital heart disease have been established. The etiology of kidneydisease has commonly been considered to be secondary to focal segmental glomerulosclerosis (FSGS), however, this has only been demonstrated in case reports and not in observational or clinical trials. AIM To identify baseline and clinical characteristics, as well as the findings in kidney biopsies of patients with congenital heart disease in our hospital. METHODS This is a retrospective observational study conducted at the Nephrology Department of the National Institute of Cardiology “Ignacio Chávez”. All patients over 16 years old who underwent percutaneous kidney biopsy from January 2000 to January 2023 with congenital heart disease were included in the study. RESULTS Ten patients with congenital heart disease and kidney biopsy were found. The average age was 29.00 years ± 15.87 years with pre-biopsy proteinuria of 6193 mg/24 h ± 6165 mg/24 h. The most common congenital heart disease was Fallot’s tetralogy with 2 cases (20%) and ventricular septal defect with 2 (20%) cases. Among the 10 cases, one case of IgA nephropathy and one case of membranoproliferative glomerulonephritis associated with immune complexes were found, receiving specific treatment after histopathological diagnosis, delaying the initiation of kidney replacement therapy. Among remaining 8 cases (80%), one case of FSGS with perihilar variety was found, while the other 7 cases were non-specific FSGS. CONCLUSION Determining the cause of chronic kidney disease can help in delaying the need for kidney replacement therapy. In 2 out of 10 patients in our study, interventions were performed, and initiation of kidney replacement therapy was delayed. Prospective studies are needed to determine the usefulness of kidney biopsy in patients with congenital heart disease.

31 December 2021 in Kidney and Dialysis
Verified
Journal Article
Open access
PDF file
SLSalvador López-Gil
Salvador López-Gil
MMMagdalena Madero
Magdalena Madero
Based on our experience in our hemodiafiltration unit we would recommend a personalized isonatremic dialysate bath. We currently prescribe 137 meq (isonatremic) or delta dialysate Na/serum Na less than 2 meq. In addition to the sodium prescribed in the dialysate, for the majority of our patients we do not restrict dietary sodium or water intake. The average sodium intake is 2775 mg per day and blood pressure is maintained without hypertensive medications. We acknowledge that part of the success for achieving dry weight may not be attributable only to the dialysate sodium but is likely the result of a combination of multiple factors such as convection therapy, cooling of dialysate, close monitoring of volume status during sessions with relative blood volume, presence of a nephrologist during all sessions and assessing volume status regularly with lung ultrasound and bioimpedance. In our experience, exercising during hemodialysis has additionally been associated with better hemodynamic status and less intradialytic hypotension. Moreover, we acknowledge there is little evidence to support a gradient dialysate to serum sodium of less than 2 meq and that our approach may not be optimal.