Ge Li

Mrs. Ge Li

Xi'an Jiaotong University
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
GLGe Li
Ge Li
LHLee Hakey
Lee Hakey
XTXiaoyan Tian
Xiaoyan Tian
ZOZeyu Ouyang
Zeyu Ouyang
XKXiaoya Kang
Xiaoya Kang
XJXinbiao Jiang
Xinbiao Jiang
Heat-pipe-cooled microreactors (HPMR) use a passive high-temperature alkali metal heat pipe to directly transfer the heat of solid core to the hot end of the intermediate heat exchanger or thermoelectric conversion device, thus avoiding a single point failure. To analyze and evaluate the transient safety characteristics of an HPMR system under accident conditions, such as heat pipe failure in the core or a loss of system heat sink and other accidents, a previously developed model for transient analysis of a heat-pipe-cooled space nuclear reactor power system (HPSR) was improved and validated in this study. The models improved mainly comprise: (1) An entire 2-D solid-core heat transfer model is established to analyze the accident conditions of core heat pipe failure and system heat sink loss. In this model, radial and axial Fourier heat conduction equations are used to divide the core into r-θ direction control volumes. The physical parameters of the material in the control volume are calculated according to the volume-weighted average. (2) By coupling the heat transfer limit model and the two-dimensional thermal resistance network model, the transient model of a heat pipe for HPMR system analysis is improved. (3) Conversion system models are established to simulate the system characteristics of the advanced HPMR concept, such as thermoelectric conversion, Stirling conversion, and the open Brayton conversion analysis model. Based on the improved models, the HPMR system analysis program TAPIRSD was developed, which was verified by experimental data of the separated conversion components and the ground nuclear test device KRUSTY. The maximum deviation of the power output predicted by the energy conversion model is less than 8%. The accident conditions of the KRUSTY tests, such as load change, core heat pipe failure, and heat sink loss accident, were studied by using TAPIRSD. The results show that the simulation results of the TAPIRSD code agree well with the experimental data of the KRUSTY prototype reactor. The maximum error between the TAPIRSD code prediction and the measured value of the core temperature under accident conditions is less than 10 K, and the maximum deviation is less than 2%. The results show that the developed code can predict the transient response process of the HPMR system well. At the same time, the accuracy and reliability of the improved model are proved. The TAPIRSD is suitable for system transient analysis of different types of HPMRs and provides an optional tool for the system safety characteristics analysis of HPMR.

27 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
HLHuaqi Li
Huaqi Li
XTXiaoyan Tian
Xiaoyan Tian
LHLee Hakey
Lee Hakey
XKXiaoya Kang
Xiaoya Kang
LZLei Zhu
Lei Zhu
JSJianqiang Shan
Jianqiang Shan
Space nuclear reactor power system (SNRPS) is a priority technical solution to meet the future space power requirement of high-power, low-mass, and long-life. The thermoelectric conversion subsystem is the key component of SNRPS, which greatly affects the performance, quality, and volume of SNRPS. Among all kinds of proposed thermoelectric conversion technologies, the free-piston Stirling power converter (FPSPC) has become a preferred conversion technology for small-scale advanced SNPRS due to its moderate waste heat emission temperature and high conversion efficiency, mainly composed of a linear alternator and free-piston Stirling engine (FPSE). For studying the performance of FPSPC, a quasi-steady flow thermodynamic cycle analysis model considering parasitic heat losses has been developed for FPSE. And then the performance analysis model for FPSPC has been established by coupling the thermodynamic cycle analysis model with the mechanical motion model of the piston and volt-ampere characteristic model of the linear alternator. Furthermore, the analysis model was compared and validated by the GPU-3 Stirling engine’s experimental data. The performance parameters of Component Test Power Converter (CTPT) FPSPC designed by NASA for SNRPS were also analyzed. The results show that the amplitudes position of CTPC displacer and piston are 15.1 mm and 11.2 mm, respectively. The corresponding average electric power output of CTPC is 17.316 kW. The input thermal power to the CTPT heater is 66.1 kW, leading to the converter efficiency of 26.2%. The average current and voltage of the CTPC alternator are 86.38 A and 193.15 V, respectively. Among all kinds of parasitic energy losses, the regenerator heat loss accounts for the largest proportion, with an average of about 12.7 kW. The effects of cooler and heater temperature on the performance of CTPC FPSPC were also studied.

19 September 2017 in Science and Technology of Nuclear Installations
Verified
Journal Article
Open access
PDF file
GLGe Li
Ge Li
WLWei Liu
Wei Liu
JSJianqiang Shan
Jianqiang Shan
This paper presents a faster solver named NRLU (Node Reordering Lower Upper) factorization solver to improve the solution speed for the pressure equations, which are formed by RELAP5/MOD3.3. The NRLU solver uses the oriented graph method and minimal fill-ins rule to reorder the structure of the nonsymmetry sparse pressure matrix. It solves the pressure matrix by LU factorization. Then the solver is embedded into the large scale advanced thermal-hydraulic system analysis program RELAP5/MOD3.3. The comparisons of the original solver and the NRLU solver show that the NRLU solver is faster than the original solver in RELAP5/MOD3.3, and the rate enhancement can be 44.44%. The results also show that the NRLU solver can reduce the number of fill-ins effectively. This can improve the calculation speed.

3 February 2018 in Diabetes Research and Clinical Practice
Verified
Journal Article
Closed access
PDF file
XHXiaofei Huang
Xiaofei Huang
SLSha Li
Sha Li
MYMei Yang
Mei Yang
XFXuquan Fu
Xuquan Fu
LHLee Hakey
Lee Hakey
XZXiaowei Zhong
Xiaowei Zhong

16 December 2023 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
BYBowen Yang
Bowen Yang
JSJianqiang Shan
Jianqiang Shan
GLGe Li
Ge Li
ZWZhao Wu
Zhao Wu
MLMingxu Liu
Mingxu Liu

15 November 2023 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
GLGe Li
Ge Li
WJWang Jingxin
Wang Jingxin
FKFan Kun
Fan Kun
ZJZhang Jie
Zhang Jie
SJShan Jianqiang
Shan Jianqiang
The liquid lead-bismuth cooled fast reactor has been in a single-phase, low-pressure, and high-temperature state for a long time during operation. Considering the requirement of calculation efficiency for long-term transient accident calculation, based on a homogeneous hydrodynamic model, one-dimensional heat conduction model, coolant flow and heat transfer model, neutron kinetics model, coolant and material properties model, this study used the fully implicit difference scheme algorithm of the convection-diffusion term to solve the basic conservation equation, to develop the transient analysis program NUSOL-LMR 2.0 for the lead-bismuth fast reactor system. The steady-state and typical design basis accidents (including reactivity introduction, loss of flow caused by main pump idling, excessive cooling, and plant power outage accidents) for the ABR have been analyzed. The results are compared with the international system analysis software ATHENA. The results indicate that the developed program can stably, accurately, and efficiently predict the transient accident response and safety characteristics of the lead-bismuth fast reactor system.