Daniel Jie Yuan Chin

Mr. Daniel Jie Yuan Chin


Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Journal of Hepatology
Verified
Journal Article
Closed access
ATAnthony T. Tan
Anthony T. Tan
LHLong Truong Hoang
Long Truong Hoang
DCDaniel Jie Yuan Chin
Daniel Jie Yuan Chin
ERErik Rasmussen
Erik Rasmussen
ULUri Lopatin
Uri Lopatin
MHMartin Hibberd
Martin Hibberd

1 August 1996 in Journal of Investigative Dermatology
Verified
Journal Article
Closed access
CGCristina Giachetti
Cristina Giachetti
DCDaniel Jie Yuan Chin
Daniel Jie Yuan Chin

29 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
DCDaniel Jie Yuan Chin
Daniel Jie Yuan Chin
AMAhmad Sufril Azlan Mohamed
Ahmad Sufril Azlan Mohamed
Khairul Anuar ShariffKhairul Anuar Shariff
Khairul Anuar Shariff
Mohd Nadhir Ab WahabMohd Nadhir Ab Wahab
Mohd Nadhir Ab Wahab
KIKunio Ishikawa
Kunio Ishikawa
Three-dimensional reconstruction plays a vital role in assisting doctors and surgeons in diagnosing the healing progress of bone defects. Common three-dimensional reconstruction methods include surface and volume rendering. As the focus is on the shape of the bone, this study omits the volume rendering methods. Many improvements have been made to surface rendering methods like Marching Cubes and Marching Tetrahedra, but not many on working towards real-time or near real-time surface rendering for large medical images and studying the effects of different parameter settings for the improvements. Hence, this study attempts near real-time surface rendering for large medical images. Different parameter values are experimented on to study their effect on reconstruction accuracy, reconstruction and rendering time, and the number of vertices and faces. The proposed improvement involving three-dimensional data smoothing with convolution kernel Gaussian size 5 and mesh simplification reduction factor of 0.1 is the best parameter value combination for achieving a good balance between high reconstruction accuracy, low total execution time, and a low number of vertices and faces. It has successfully increased reconstruction accuracy by 0.0235%, decreased the total execution time by 69.81%, and decreased the number of vertices and faces by 86.57% and 86.61%, respectively.


1 January 2014 in Journal of Hepatology
Verified
Journal Article
Open access
SFScott Laurence Friedman
Scott Laurence Friedman
DSDidier Samuel
Didier Samuel
MPMarkus Peck‐Radosavljevic
Markus Peck‐Radosavljevic
MCMary E. Charlton
Mary E. Charlton
Thomas DickThomas Dick
Thomas Dick
COC Oõfarrelly
C Oõfarrelly

25 October 2021 in Preprints.org
Verified
Preprint
Open access
PDF file
DCDaniel Jie Yuan Chin
Daniel Jie Yuan Chin
AMAhmad Sufril Azlan Mohamed
Ahmad Sufril Azlan Mohamed
Khairul Anuar ShariffKhairul Anuar Shariff
Khairul Anuar Shariff
Mohd Nadhir Ab WahabMohd Nadhir Ab Wahab
Mohd Nadhir Ab Wahab
KIKunio Ishikawa
Kunio Ishikawa
Three-dimensional reconstruction plays an important role in assisting doctors and surgeons in diagnosing bone defects’ healing progress. Common three-dimensional reconstruction methods include surface and volume rendering. As the focus is on the shape of the bone, volume rendering is omitted. Many improvements have been made on surface rendering methods like Marching Cubes and Marching Tetrahedra, but not many on working towards real-time or near real-time surface rendering for large medical images, and studying the effects of different parameter settings for the improvements. Hence, in this study, an attempt towards near real-time surface rendering for large medical images is made. Different parameter values are experimented on to study their effect on reconstruction accuracy, reconstruction and rendering time, and the number of vertices and faces. The proposed improvement involving three-dimensional data smoothing with convolution kernel Gaussian size 0.5 and mesh simplification reduction factor of 0.1, is the best parameter value combination for achieving a good balance between high reconstruction accuracy, low total execution time, and a low number of vertices and faces. It has successfully increased the reconstruction accuracy by 0.0235%, decreased the total execution time by 69.81%, and decreased the number of vertices and faces by 86.57% and 86.61% respectively.