Se An OH

Prof. Dr. Se An OH

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Progress in Medical Physics
Verified
Journal Article
Open access
PDF file
SOSe An OH
Se An OH
MKMin Kyu Kang
Min Kyu Kang
SKSung Kyu Kim
Sung Kyu Kim
JYJi Woon Yea
Ji Woon Yea

20 July 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JYJi Woon Yea
Ji Woon Yea
JPJaewon Park
Jaewon Park
SKSung Kyu Kim
Sung Kyu Kim
DKDong Youn Kim
Dong Youn Kim
JKJae Gu Kim
Jae Gu Kim
SOSe An OH
Se An OH
This study evaluated the feasibility of utilizing a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Contoured left and right head phantoms were converted from DICOM to STL format. Fused deposition modeling (FDM) was used to construct an anthropomorphic patient-specific head phantom with a 3D printer. An established QA technique and the patient-specific head phantom were used to compare the calculated and measured doses. When the established technique was used to compare the calculated and measured doses, the gamma passing rate for γ ≤ 1 was 97.28%, while the gamma failure rate for γ > 1 was 2.72%. When the 3D-printed patient-specific head phantom was used, the gamma passing rate for γ ≤ 1 was 95.97%, and the gamma failure rate for γ > 1 was 4.03%. The 3D printed patient-specific head phantom was concluded to be highly feasible for patient-specific QA prior to complicated radiotherapy procedures such as IMRT.

13 March 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SOSe An OH
Se An OH
JYJi Woon Yea
Ji Woon Yea
SKSung Kyu Kim
Sung Kyu Kim
JPJaewon Park
Jaewon Park
Respiratory-gated radiotherapy is one of the most effective approaches to minimise radiation dose delivery to normal tissue and maximise delivery to tumours under patient’s motion caused by respiration. We propose a respiration guiding system based on real-time position management with suitable gating window for respiratory-gated radiotherapy applied to liver cancer. Between August 2016 and February 2018, 52 patients with liver cancer received training in real-time position management and respiration guiding. Respiration signals were statistically analysed during unguided respiration and when applying the respiration guiding system. Phases of 30–60% and 30–70% retrieved the lowest respiration variability among patients, and 47 patients exhibited significant differences in terms of respiration reproducibility between unguided and guided respiration. The results suggest that either of these phases can establish suitable windows for gated radiotherapy applied to liver cancer, especially regarding respiration reproducibility.

14 November 2021 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
JPJaehyeon Park
Jaehyeon Park
JYJi Woon Yea
Ji Woon Yea
SOSe An OH
Se An OH
JPJaewon Park
Jaewon Park
Background: Neoadjuvant chemoradiotherapy (nCRT) followed by surgery is a standard treatment modality for locally-advanced esophageal cancer. However, patients who achieve clinical complete response (cCR) after nCRT have been reported to have better prognosis. Further, the role of surgery in these patients is controversial. Thus, this meta-analysis aimed to evaluate whether surgery is still useful in patients with cCR after nCRT. Methods: We systematically reviewed the MEDLINE, PubMed, Embase, Cochrane library, and Scopus databases for studies on surgical efficacy in complete responders after concurrent chemoradiotherapy for esophageal cancer. The publication date was set to January 1, 2010–January 31, 2020. The hazard ratio (HR) and risk ratio were used to compare the 2-year overall survival (OS), disease-free survival (DFS), incidence of locoregional failure, distant metastasis, and treatment mortality between the nCRT and nCRT plus surgery groups. Results: Six articles involving 609 patients were included. There was a significant benefit of nCRT for OS (HR = 0.80, 95% confidence interval [CI] 0.64–0.99, p = 0.04), but not for DFS (HR = 1.55, 95% CI 0.35–6.86, p = 0.56). The nCRT group tended to have lower mortality than the nCRT plus surgery group (risk ratio = 0.15, 95% CI 0.02–1.18, p = 0.07). Conclusion: Omitting surgery provides better OS in complete responders after nCRT. Adding surgery could increase the morbidity and mortality and decrease the quality of life. Thus, nCRT alone could be a feasible approach for patients with cCR.

19 October 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SKSung Yeop Kim
Sung Yeop Kim
JPJae Won Park
Jae Won Park
JPJaehyeon Park
Jaehyeon Park
JYJi Woon Yea
Ji Woon Yea
SOSe An OH
Se An OH
This study aimed to fabricate a heterogeneous phantom replicating the commercial Rando phantom by mixing plaster powder and polylactic acid (PLA) powder. Producing a heterogeneous phantom using Plaster and PLA is cheaper because it can be easily obtained in the commercial market. Additionally, patient-specific Quality Assurance can be easily performed because the phantom can be produced based on the patient’s CT image. PLA has been well studied in the field of radiation therapy and was found to be safe and effective. To match the mean Hounsfield unit (HU) values of the Rando phantom, the bone tissue was changed using plaster and 0–35% PLA powder until an appropriate HU value was obtained, and soft tissue was changed using the PLA infill value until an appropriate HU value was obtained. Bone tissue (200 HU or higher), soft issue (− 500 to 200 HU), and air cavity (less than − 500 HU) were modeled based on the HU values on the computed tomography (CT) image. The bone tissue was modeled as a cavity, and after three-dimensional (3D) printing, a solution containing a mixture of plaster and PLA powder was poured. To evaluate the bone implementation of the phantom obtained by the mixture of plaster and PLA powder, the HU profile of the CT images of the 3D-printed phantom using only PLA and the Rando phantom printed using only PLA was evaluated. The mean HU value for soft tissue in the Rando phantom (− 22.5 HU) showed the greatest similarity to the result obtained with an infill value of 82% (− 20 HU). The mean HU value for bone tissue (669 HU) showed the greatest similarity to the value obtained with 15% PLA powder (680 HU). Thus, for the phantom composed of plaster mixed with PLA powder, soft tissue was fabricated using a 3D printer with an infill value of 82%, and bone tissue was fabricated with a mixture containing 15% PLA powder. In the HU profile, this phantom showed a mean difference of 61 HU for soft tissue and 109 HU for bone tissue in comparison with the Rando phantom. The ratio of PLA powder and plaster can be adjusted to achieve an HU value similar to bone tissue. A simple combination of PLA powder and plaster enabled the creation of a custom phantom that showed similarities to the Rando phantom in both soft tissue and bone tissue.

13 June 2012 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
PDF file
SOSe An OH
Se An OH
MKMin Kyu Kang
Min Kyu Kang
JYJi Woon Yea
Ji Woon Yea
SKSung-Kyu Kim
Sung-Kyu Kim
YOYoung Kee Oh
Young Kee Oh