Jaewon Park

Prof. Jaewon Park

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

20 July 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JYJi Woon Yea
Ji Woon Yea
JPJaewon Park
Jaewon Park
SKSung Kyu Kim
Sung Kyu Kim
DKDong Youn Kim
Dong Youn Kim
JKJae Gu Kim
Jae Gu Kim
SOSe An OH
Se An OH
This study evaluated the feasibility of utilizing a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Contoured left and right head phantoms were converted from DICOM to STL format. Fused deposition modeling (FDM) was used to construct an anthropomorphic patient-specific head phantom with a 3D printer. An established QA technique and the patient-specific head phantom were used to compare the calculated and measured doses. When the established technique was used to compare the calculated and measured doses, the gamma passing rate for γ ≤ 1 was 97.28%, while the gamma failure rate for γ > 1 was 2.72%. When the 3D-printed patient-specific head phantom was used, the gamma passing rate for γ ≤ 1 was 95.97%, and the gamma failure rate for γ > 1 was 4.03%. The 3D printed patient-specific head phantom was concluded to be highly feasible for patient-specific QA prior to complicated radiotherapy procedures such as IMRT.

1 February 2016 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
JYJeong Il Yu
Jeong Il Yu
JPJaewon Park
Jaewon Park
HPHee Chul Park
Hee Chul Park
SYSang Min Yoon
Sang Min Yoon
DLDo Hoon Lim
Do Hoon Lim
JKJong Hoon Kim
Jong Hoon Kim

28 March 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SOSe An Oh
Se An Oh
JYJi Woon Yea
Ji Woon Yea
MKMin Kyu Kang
Min Kyu Kang
JPJaewon Park
Jaewon Park
SKSung-Kyu Kim
Sung-Kyu Kim
This study evaluated the setup uncertainties for brain sites when using BrainLAB’s ExacTrac X-ray 6D system for daily pretreatment to determine the optimal planning target volume (PTV) margin. Between August 2012 and April 2015, 28 patients with brain tumors were treated by daily image-guided radiotherapy using the BrainLAB ExacTrac 6D image guidance system of the Novalis-Tx linear accelerator. DUONTM (Orfit Industries, Wijnegem, Belgium) masks were used to fix the head. The radiotherapy was fractionated into 27–33 treatments. In total, 844 image verifications were performed for 28 patients and used for the analysis. The setup corrections along with the systematic and random errors were analyzed for six degrees of freedom in the translational (lateral, longitudinal, and vertical) and rotational (pitch, roll, and yaw) dimensions. Optimal PTV margins were calculated based on van Herk et al.’s [margin recipe = 2.5∑ + 0.7σ - 3 mm] and Stroom et al.’s [margin recipe = 2∑ + 0.7σ] formulas. The systematic errors (∑) were 0.72, 1.57, and 0.97 mm in the lateral, longitudinal, and vertical translational dimensions, respectively, and 0.72°, 0.87°, and 0.83° in the pitch, roll, and yaw rotational dimensions, respectively. The random errors (σ) were 0.31, 0.46, and 0.54 mm in the lateral, longitudinal, and vertical rotational dimensions, respectively, and 0.28°, 0.24°, and 0.31° in the pitch, roll, and yaw rotational dimensions, respectively. According to van Herk et al.’s and Stroom et al.’s recipes, the recommended lateral PTV margins were 0.97 and 1.66 mm, respectively; the longitudinal margins were 1.26 and 3.47 mm, respectively; and the vertical margins were 0.21 and 2.31 mm, respectively. Therefore, daily setup verifications using the BrainLAB ExacTrac 6D image guide system are very useful for evaluating the setup uncertainties and determining the setup margin.

11 May 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JPJaewon Park
Jaewon Park
SOSe An Oh
Se An Oh
JYJi Woon Yea
Ji Woon Yea
MKMin Kyu Kang
Min Kyu Kang
A three-dimensional (3D)-printed customized bolus (3D bolus) can be used for radiotherapy application to irregular surfaces. However, bolus fabrication based on computed tomography (CT) scans is complicated and also delivers unwanted irradiation. Consequently, we fabricated a bolus using a 3D scanner and evaluated its efficacy. The head of an Alderson Rando phantom was scanned with a 3D scanner. The 3D surface data were exported and reconstructed with Geomagic Design X software. A 3D bolus of 5-mm thickness designed to fit onto the nose was printed with the use of rubber-like printing material, and a radiotherapy plan was developed. We successfully fabricated the customized 3D bolus, and further, a CT simulation indicated an acceptable fit of the 3D bolus to the nose. There was no air gap between the bolus and the phantom surface. The percent depth dose (PDD) curve of the phantom with the 3D bolus showed an enhanced surface dose when compared with that of the phantom without the bolus. The PDD of the 3D bolus was comparable with that of a commercial superflab bolus. The radiotherapy plan considering the 3D bolus showed improved target coverage when compared with that without the bolus. Thus, we successfully fabricated a customized 3D bolus for an irregular surface using a 3D scanner instead of a CT scanner.

13 December 2012 in Medical Physics
Verified
Journal Article
Closed access
PDF file
SJSang Hoon Jung
Sang Hoon Jung
SYSang Min Yoon
Sang Min Yoon
SPSung Ho Park
Sung Ho Park
BCByungchul Cho
Byungchul Cho
JPJaewon Park
Jaewon Park
SASeung Do Ahn
Seung Do Ahn