We obtained high-resolution spectra of Jupiter between 4.6 and 5.4 µm using NIRSPEC on the Keck 2 telescope in February 2017. We measured the spatial variation of NH, HO, and the pressure level of deep (p > 3 bar) clouds using two geometries. We aligned the slit north–south on Jupiter’s Central Meridian to measure the spatial variation of the gas composition and cloud structure between 66N and 70S. With the slit aligned east–west, we also examined the longitudinal variation at two regions of the North Equatorial Belt (NEB) at 18N and at 8N near the latitude of the Galileo Probe entry site. We used the integrated line absorption, also known as the equivalent width, of deuterated methane (CHD) at 4.66 µm to derive the pressure level of deep clouds between 3 and 7 bar. From thermochemical models, these are most likely water clouds. At the location of a deep cloud revealed by HST methane-band imaging, we found spectroscopic evidence for an opaque cloud at the 5 bar level. We also identified regions on Jupiter that lacked deep clouds but exhibited evidence for upper clouds and enhanced NH. We estimated column-averaged mole fractions of HO and NH above the opaque lower boundary of the deep cloud. The meridional scan exhibited significant belt-zone structure with retrieved NH abundances in the 200–400 ppm range above the opaque lower cloud, except for a depletion (down to 90 ppm) in the NEB. Water in Jupiter’s belts varies from a maximum of 7 ppm at 8S to a minimum of 1.5 ppm at 23S. We found evidence for water clouds and enhanced NH and HO in the South Equatorial Belt Outbreak region at 13S. The NEB is a heterogeneous region with significant variation in all of these quantities. The NH abundance at 18N and 8N varies with the longitude with mole fractions between 120 and 300 ppm. The HO abundance at these same latitudes varies with the longitude with mole fractions between 3 and 10 ppm. Our volatile mole fractions apply to the 5 to 8 bar pressure range (or to the level of an opaque cloud top where found at shallower pressure); therefore, they imply a deeper gradient continuing to increase toward higher concentrations detected by the Galileo Probe Mass Spectrometer at 11 and 20 bar. Hot Spots in the NEB exhibit minimal cloud opacity; however, they lack prominent anomalies in the concentrations of NH or HO.
1 December 2021 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
The demonstration of a newly developed compact thermal imager (CTI) on the International Space Station (ISS) has provided not only a technology advancement but a rich high-resolution dataset on global clouds, atmospheric and land emissions. This study showed that the free-running CTI instrument could be calibrated to produce scientifically useful radiance imagery of the atmosphere, clouds, and surfaces with a vertical resolution of ~460 m at limb and a horizontal resolution of ~80 m at nadir. The new detector demonstrated an excellent sensitivity to detect the weak limb radiance perturbations modulated by small-scale atmospheric gravity waves. The CTI’s high-resolution imaging was used to infer vertical cloud temperature profiles from a side-viewing geometry. For nadir imaging, the combined high-resolution and high-sensitivity capabilities allowed the CTI to better separate cloud and surface emissions, including those in the planetary boundary layer (PBL) that had small contrast against the background surface. Finally, based on the ISS’s orbit, the stable detector performance and robust calibration algorithm produced valuable diurnal observations of cloud and surface emissions with respect to solar local time during May–October 2019, when the CTI had nearly continuous operation.
Thermal imaging is used in security cameras, fire detection, driver assist features in automobiles, medical thermography and other safety applications. Unfortunately, lenses for thermal cameras are made from expensive or restricted materials such as germanium, silicon, or chalcogenide glass, which limits broader use. There is a need for low cost and sustainable alternatives. Sulfur-rich polymers, made from widely available elemental sulfur, are promising candidates due to their high refractive index and mid-wave infrared (MWIR, 3–5 um) and long-wave infrared (LWIR, 7–14 um) transmittance. However, much higher MWIR and LWIR transparencies are required to compete with industry standards. Recently, a copolymer containing a sulfurized norbornane core (1) was predicted by Pyun, based on theoretical considerations, to address this need. However, this polymer has not been made due to complex chemistry encountered in previously attempted syntheses. Here, we overcome these challenges and synthesize this polymer for the first time and validate its use in thermal imaging.