Haroon Khan

Mr. Haroon Khan

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
HKHaroon Khan
Haroon Khan
FNFarzan Majeed Noori
Farzan Majeed Noori
AYAnis Yazidi
Anis Yazidi
Md Zia UddinMd Zia Uddin
Md Zia Uddin
MKM. N. Afzal Khan
M. N. Afzal Khan
PMPeyman Mirtaheri
Peyman Mirtaheri
Functional near-infrared spectroscopy (fNIRS) is a comparatively new noninvasive, portable, and easy-to-use brain imaging modality. However, complicated dexterous tasks such as individual finger-tapping, particularly using one hand, have been not investigated using fNIRS technology. Twenty-four healthy volunteers participated in the individual finger-tapping experiment. Data were acquired from the motor cortex using sixteen sources and sixteen detectors. In this preliminary study, we applied standard fNIRS data processing pipeline, i.e., optical densities conversation, signal processing, feature extraction, and classification algorithm implementation. Physiological and non-physiological noise is removed using 4th order band-pass Butter-worth and 3rd order Savitzky–Golay filters. Eight spatial statistical features were selected: signal-mean, peak, minimum, Skewness, Kurtosis, variance, median, and peak-to-peak form data of oxygenated haemoglobin changes. Sophisticated machine learning algorithms were applied, such as support vector machine (SVM), random forests (RF), decision trees (DT), AdaBoost, quadratic discriminant analysis (QDA), Artificial neural networks (ANN), k-nearest neighbors (kNN), and extreme gradient boosting (XGBoost). The average classification accuracies achieved were 0.75±0.04, 0.75±0.05, and 0.77±0.06 using k-nearest neighbors (kNN), Random forest (RF) and XGBoost, respectively. KNN, RF and XGBoost classifiers performed exceptionally well on such a high-class problem. The results need to be further investigated. In the future, a more in-depth analysis of the signal in both temporal and spatial domains will be conducted to investigate the underlying facts. The accuracies achieved are promising results and could open up a new research direction leading to enrichment of control commands generation for fNIRS-based brain-computer interface applications.

16 February 2024 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
HKHaroon Khan
Haroon Khan
RKRabindra Khadka
Rabindra Khadka
MSMalik Shahid Sultan
Malik Shahid Sultan
AYAnis Yazidi
Anis Yazidi
HOHernando Ombao
Hernando Ombao
PMPeyman Mirtaheri
Peyman Mirtaheri
In this study, we explore the potential of using functional near-infrared spectroscopy (fNIRS) signals in conjunction with modern machine-learning techniques to classify specific anatomical movements to increase the number of control commands for a possible fNIRS-based brain-computer interface (BCI) applications. The study focuses on novel individual finger-tapping, a well-known task in fNIRS and fMRI studies, but limited to left/right or few fingers. Twenty-four right-handed participants performed the individual finger-tapping task. Data were recorded by using sixteen sources and detectors placed over the motor cortex according to the 10-10 international system. The event's average oxygenated ∆ HbO and deoxygenated ∆HbR hemoglobin data were utilized as features to assess the performance of diverse machine learning (ML) models in a challenging multi-class classification setting. These methods include LDA, QDA, MNLR, XGBoost, and RF. A new DL-based model named `Hemo-Net' has been proposed which consists of multiple parallel convolution layers with different filters to extract the features. This paper aims to explore the efficacy of using fNRIS along with ML/DL methods in a multi-class classification task. Complex models like RF, XGBoost, and Hemo-Net produce relatively higher test set accuracy when compared to LDA, MNLR, and QDA. Hemo-Net has depicted a superior performance achieving the highest test set accuracy of $76 \%$, however, in this work, we do not aim at improving the accuracies of models rather we are interested in exploring if fNIRS has the neural signatures to help modern ML/DL methods in multi-class classification which can lead to applications like brain-computer interfaces. Multi-class classification of fine anatomical movements, such as individual finger movements, is difficult to classify with fNIRS data. Traditional ML models like MNLR and LDA show inferior performance compared to the ensemble-based methods of RF and XGBoost. DL-based method Hemo-Net outperforms all methods evaluated in this study and demonstrates a promising future for fNIRS-based BCI applications.

26 July 2021 in IEEE Access
Verified
Journal Article
Open access
NSNeelum Yousaf Sattar
Neelum Yousaf Sattar
ZKZareena Kausar
Zareena Kausar
SUSyed Ali Usama
Syed Ali Usama
Noman NaseerNoman Naseer
Noman Naseer
UFUmer Farooq
Umer Farooq
PMPeyman Mirtaheri
Peyman Mirtaheri
Limited non-invasive transhumeral prosthesis control exists due to the absence of signal sources on amputee residual muscles. This paper introduces a hybrid brain-machine interface (hBMI) that integrates surface electromyography (sEMG) and functional near-infrared spectroscopy (fNIRS) signals to overcome the limits of an existing myoelectric upper-limb prosthesis. This hybridization aims to improve classification accuracy (CA) to escalate arm movements' control performance for individuals who have a transhumeral amputation. To evaluate the effectiveness of this hBMI, fifteen healthy and three transhumeral amputee subjects for six arm motions were participating in the experiment. Myo armband was used to acquire sEMG signals corresponding to four arm motions: elbow extension, elbow flexion, wrist pronation, and wrist supination. Whereas, fNIRS brain imaging modality was used to monitor cortical hemodynamics response from the prefrontal cortex region for two hand motions: hand open and hand close. The average accuracy of 94.6 % and 74% was achieved for elbow and wrist motions by sEMG for healthy and amputated subjects, respectively. Simultaneously, the fNIRS modality showed an average accuracy of 96.9% and 94.5% for hand motions of healthy and amputated subjects. This study demonstrates the feasibility of hybridizing sEMG and fNIRS signals to improve the CA for transhumeral amputees, improving the control performances of multifunctional upper-limb prostheses.

10 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JAJamila Akhter
Jamila Akhter
Noman NaseerNoman Naseer
Noman Naseer
Hammad NazeerHammad Nazeer
Hammad Nazeer
HKHaroon Khan
Haroon Khan
PMPeyman Mirtaheri
Peyman Mirtaheri
Brain–computer interface (BCI) systems include signal acquisition, preprocessing, feature extraction, classification, and an application phase. In fNIRS-BCI systems, deep learning (DL) algorithms play a crucial role in enhancing accuracy. Unlike traditional machine learning (ML) classifiers, DL algorithms eliminate the need for manual feature extraction. DL neural networks automatically extract hidden patterns/features within a dataset to classify the data. In this study, a hand-gripping (closing and opening) two-class motor activity dataset from twenty healthy participants is acquired, and an integrated contextual gate network (ICGN) algorithm (proposed) is applied to that dataset to enhance the classification accuracy. The proposed algorithm extracts the features from the filtered data and generates the patterns based on the information from the previous cells within the network. Accordingly, classification is performed based on the similar generated patterns within the dataset. The accuracy of the proposed algorithm is compared with the long short-term memory (LSTM) and bidirectional long short-term memory (Bi-LSTM). The proposed ICGN algorithm yielded a classification accuracy of 91.23 ± 1.60%, which is significantly (p < 0.025) higher than the 84.89 ± 3.91 and 88.82 ± 1.96 achieved by LSTM and Bi-LSTM, respectively. An open access, three-class (right- and left-hand finger tapping and dominant foot tapping) dataset of 30 subjects is used to validate the proposed algorithm. The results show that ICGN can be efficiently used for the classification of two- and three-class problems in fNIRS-based BCI applications.

10 February 2023 in Heliyon
Verified
Journal Article
Open access
HKHaroon Khan
Haroon Khan
NQNauman Khalid Qureshi
Nauman Khalid Qureshi
AYAnis Yazidi
Anis Yazidi
HEHåvard Engell
Håvard Engell
PMPeyman Mirtaheri
Peyman Mirtaheri
Maintaining body balance, whether static or dynamic, is critical in performing everyday activities and developing and optimizing basic motor skills. This study investigates how a professional alpine skier's brain activates on the contralateral side during a single-leg stance. Continuous-wave functional near-infrared spectroscopy (fNIRS) signals were recorded with sixteen sources and detectors over the motor cortex to investigate brain hemodynamics. Three different tasks were performed: barefooted walk (BFW), right-leg stance (RLS), and left-leg stance (LLS). The signal processing pipeline includes channel rejection, the conversation of raw intensities into hemoglobin concentration changes using modified Beer-Lambert law, baseline zero-adjustments, z-normalization, and temporal filtration. The hemodynamic brain signal was estimated using a general linear model with a 2-gamma function. Measured activations (t-values) with p-value <0.05 were only considered as statistically significant active channels. Compared to all other conditions, BFW has the lowest brain activation. LLS is associated with more contralateral brain activation than RLS. During LLS, higher brain activation was observed across all brain regions. The right hemisphere has comparatively more activated regions-of-interest. Higher ΔHbO demands in the dorsolateral prefrontal, pre-motor, supplementary motor cortex, and primary motor cortex were observed in the right hemisphere relative to the left which explains higher energy demands for balancing during LLS. Broca's temporal lobe was also activated during both LLS and RLS. Comparing the results with BFW- which is considered the most realistic walking condition-, it is concluded that higher demands of ΔHbO predict higher motor control demands for balancing. The participant struggled with balance during the LLS, showing higher ΔHbO in both hemispheres compared to two other conditions, which indicates the higher requirement for motor control to maintain balance. A post-physiotherapy exercise program is expected to improve balance during LLS, leading to fewer changes to ΔHbO.

29 May 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
HKHaroon Khan
Haroon Khan
MKM. N. Afzal Khan
M. N. Afzal Khan
Usman TariqUsman Tariq
Usman Tariq
Hasan Al-NashashHasan Al-Nashash
Hasan Al-Nashash
PMPeyman Mirtaheri
Peyman Mirtaheri
Finger tapping is one of the most reliable and widely utilized tasks for evoking activity in the motor cortex area of the brain, both for the brain-computer interface (BCI) and for evaluating the progress of certain brain diseases. Keeping in view the importance of dominance of the right hand, the goal of this study is to understand the response of each finger tapping alongside proposing a suitable finger tapping task both for BCI and medical imaging. With this in mind, we recruited twenty-four healthy subjects. Functional near-infrared spectroscopy (fNIRS) was used for brain imaging while the subjects performed a series of finger-tapping tasks utilizing each of the five fingers individually. From average hemodynamic results, the middle finger tapping task showed a maximum amount of activation in the motor cortex, whereas the index finger tapping task had the minimum activation compared to the other four fingers. The little finger and ring finger tapping tasks gave the most significant and widespread activation, respectively when compared through brain activation maps. The activation was clustered on a single region for the thumb-tapping task, whereas a wider area showed a very strong activation for the little finger and ring finger tapping tasks. Conclusively, this study is a step towards standardizing finger tapping and its related motor area activations, demonstrating that little finger tapping can best suit the purpose of a finger tapping task for BCI and medical imaging applications.