The application of phase change materials (PCMs) has been verified as an effective strategy for improving energy efficiency and reducing greenhouse gas emissions. Biocomposite PCMs (Bc-PCM) exhibit large latent heat, chemical stability, and a wide temperature range. In this study, thermal conductivity improved Bc-PCM (TBc-PCM) was made via vacuum impregnation with graphene nanoplatelets (GNPs). Chemical stability analysis and thermal performance analyses of the Bc-PCM and TBc-PCM were carried out as well as building energy simulations and thermal comfort analyses. Our results show Bc-PCM showed a higher heat storage capacity and enthalpy value compared to TBc-PCM. TBc-PCM exhibited a 378% increase in thermal conductivity compared to Bc-PCM. Building energy simulation results revealed that annual heating and cooling energy consumption decreased as the thickness of the PCM layer increased. In addition, the Bc-PCM with a larger PCM capacity was more effective in reducing energy consumption during the heating period. On the other hand, the cooling energy reduction effect was greater when TBc-PCM with high thermal conductivity was applied because of the high heat transfer during the cooling period. Thermal comfort evaluation revealed it was more comfortable when PCM was applied.
The interest in zero-energy buildings has increased in Korea recently. Following the significant increases in cooling and lighting energy consumption in offices, various studies have been conducted to implement energy-saving measures. The purpose of this study is to reduce lighting and cooling energy consumption in the summer through the dimming control of a complex smart window system. To achieve this, the optimal dimming control algorithm has been derived and applied in simulations to analyze the energy consumption for lighting and cooling. A smart window incorporates suspended particle display glass that actively responds to changes in indoor and outdoor environments and controls light transmittance. It also includes a light-guiding glass that can actively control solar reflectance. Simulations of office buildings were conducted to develop optimal control algorithms and controllers based on solar radiation. Subsequently, we installed this complex smart window in a test room along with the developed control algorithm and controller, which responded to the amount of insolation and time. To ensure the accuracy of the experiment, we constructed separate test and reference rooms. The experimental results obtained under the same conditions showed a reduction of approximately 36.9% in cooling energy consumption in the test room compared with the reference room and a 54.5% reduction in lighting energy consumption. Furthermore, based on additional simulations and experiments, we confirmed that the application of complex smart window systems in office buildings could reduce considerably the energy consumption for cooling and lighting.
22 January 2025 in Construction and Building Materials