Kevin Moulin

Dr. Kevin Moulin

Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé, Villeurbanne, Auvergne-Rhône-Alpes, France
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KMKevin Moulin
Kevin Moulin
IVIlya A. Verzhbinsky
Ilya A. Verzhbinsky
NMNyasha G. Maforo
Nyasha G. Maforo
LPLuigi E. Perotti
Luigi E. Perotti
DEDaniel B. Ennis
Daniel B. Ennis
Purpose: Cardiomyocyte organization and performance underlie cardiac function, but the in vivo mobility of these cells during contraction and filling remains difficult to probe. Herein, a novel trigger delay (TD) scout sequence was used to acquire high in-plane resolution (1.6 mm) Spin-Echo (SE) cardiac diffusion tensor imaging (cDTI) at three distinct cardiac phases. The objective was to characterize cardiomyocyte organization and mobility throughout the cardiac cycle in healthy volunteers. Materials and methods: Nine healthy volunteers were imaged with cDTI at three distinct cardiac phases (early systole, late systole, and diastasis). The sequence used a free-breathing Spin-Echo (SE) cDTI protocol (b-values = 350s/mm2, twelve diffusion encoding directions, eight repetitions) to acquire high-resolution images (1.6x1.6x8mm3) at 3T in ~7 minutes/cardiac phase. Helix Angle (HA), Helix Angle Range (HAR), E2 angle (E2A), Transverse Angle (TA), Mean Diffusivity (MD), diffusion tensor eigenvalues (λ1-2-3), and Fractional Anisotropy (FA) in the left ventricle (LV) were characterized. Results: Images from the patient-specific TD scout sequence demonstrated that SE cDTI acquisition was possible at early systole, late systole, and diastasis in 78%, 100% and 67% of the cases, respectively. At the mid-ventricular level, mobility (reported as median [IQR]) was observed in HAR between early systole and late systole (76.9 [72.6, 80.5]° vs 96.6 [85.9, 100.3]°, p<0.001). E2A also changed significantly between early systole, late systole, and diastasis (27.7 [20.8, 35.1]° vs 45.2 [42.1, 49]° vs 20.7 [16.6, 26.4]°, p<0.001). Conclusion: We demonstrate that it is possible to probe cardiomyocyte mobility using multi-phase and high resolution cDTI. In healthy volunteers, aggregate cardiomyocytes re-orient themselves more longitudinally during contraction, while cardiomyocyte sheetlets tilt radially during wall thickening. These observations provide new insights into the three-dimensional mobility of myocardial microstructure during systolic contraction.

1 June 2020 in Radiology
Verified
Journal Article
Closed access
KMKevin Moulin
Kevin Moulin
Magalie ViallonMagalie Viallon
Magalie Viallon
WRWilliam Romero
William Romero
ACAlban Chazot
Alban Chazot
NMNathan Mewton
Nathan Mewton
PCPierre Croisille
Pierre Croisille
Apparent diffusion coefficient maps of the myocardium showed improvement in the depiction of myocardial edema compared with T1 and T2 images. Background After acute myocardial infarction (AMI), reperfusion injury is associated with microvascular lesions and myocardial edema. Purpose To evaluate the performance of apparent diffusion coeff...

12 September 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
KMKevin Moulin
Kevin Moulin
EAEric Aliotta
Eric Aliotta
DEDaniel B. Ennis
Daniel B. Ennis

22 February 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
KMKevin Moulin
Kevin Moulin
PCPierre Croisille
Pierre Croisille
Magalie ViallonMagalie Viallon
Magalie Viallon
IVIlya A. Verzhbinsky
Ilya A. Verzhbinsky
LPLuigi Perotti
Luigi Perotti
DEDaniel Bruce Ennis
Daniel Bruce Ennis

29 December 2021 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
ITIrvin Teh
Irvin Teh
WRWilliam A. Romero R.
William A. Romero R.
JBJordan Boyle
Jordan Boyle
JCJaume Coll-Font
Jaume Coll-Font
EDErica Dall'ARmellina
Erica Dall'ARmellina
JSJürgen E. Schneider
Jürgen E. Schneider
Cardiac diffusion tensor imaging (DTI) is an emerging technique for the in vivo characterisation of myocardial microstructure, and there is a growing need for its validation and standardisation. We sought to establish the accuracy, precision, repeatability and reproducibility of state‐of‐the‐art pulse sequences for cardiac DTI among 10 centres internationally. Phantoms comprising 0%–20% polyvinylpyrrolidone (PVP) were scanned with DTI using a product pulsed gradient spin echo (PGSE; N = 10 sites) sequence, and a custom motion‐compensated spin echo (SE; N = 5) or stimulated echo acquisition mode (STEAM; N = 5) sequence suitable for cardiac DTI in vivo. A second identical scan was performed 1–9 days later, and the data were analysed centrally. The average mean diffusivities (MDs) in 0% PVP were (1.124, 1.130, 1.113) x 10−3 mm2/s for PGSE, SE and STEAM, respectively, and accurate to within 1.5% of reference data from the literature. The coefficients of variation in MDs across sites were 2.6%, 3.1% and 2.1% for PGSE, SE and STEAM, respectively, and were similar to previous studies using only PGSE. Reproducibility in MD was excellent, with mean differences in PGSE, SE and STEAM of (0.3 ± 2.3, 0.24 ± 0.95, 0.52 ± 0.58) x 10−5 mm2/s (mean ± 1.96 SD). We show that custom sequences for cardiac DTI provide accurate, precise, repeatable and reproducible measurements. Further work in anisotropic and/or deforming phantoms is warranted.

26 February 2025 in IEEE Access
Verified
Journal Article
Open access
LZLuca Zilberti
Luca Zilberti
AAAlessandro Arduino
Alessandro Arduino
UZUmberto Zanovello
Umberto Zanovello
JMJessica A. Martinez
Jessica A. Martinez
KMKevin Moulin
Kevin Moulin
OBOriano Bottauscio
Oriano Bottauscio
A new approach to Magnetic Resonance-based Electric Properties Tomography (EPT) is presented. The method applies Green’s integral identity to the equation that regulates the EPT problem. The resultant integral equations are used to impose the consistency of the measured values of the radiofrequency field. This is achieved by seeking dielectric properties values that allow satisfying the identity within suitable kernels of voxels. In each kernel, an overdetermined system of equations is written, and the corresponding problem is solved in the least squares sense, providing an index of trustworthiness of the solution. Both the complete formulation and its phase-based approximation are presented. The application of a filter, which post-processes the raw results based on the index of trustworthiness, is also discussed. The performance of the method is evaluated on synthetic data and experimental measurements acquired on a heterogeneous brain phantom and on four human volunteers. The reconstructions are compared to those produced through a Helmholtz-EPT with adaptive kernel. The new EPT method performs well in all tests.