Francisco Javier Aguilar Valero

Dr. Francisco Javier Aguilar Valero

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in Applied Thermal Engineering
Verified
Journal Article
Closed access
FVFrancisco Javier Aguilar Valero
Francisco Javier Aguilar Valero
SAS. Aledo
S. Aledo
PQP. V. Quiles
P. V. Quiles

1 May 2016 in Applied Thermal Engineering
Verified
Journal Article
Closed access
FVFrancisco Javier Aguilar Valero
Francisco Javier Aguilar Valero
SAS. Aledo
S. Aledo
PQP. V. Quiles
P. V. Quiles

2 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
FVFrancisco Javier Aguilar Valero
Francisco Javier Aguilar Valero
JAVIER RUIZ RAMÍREZJAVIER RUIZ RAMÍREZ
JAVIER RUIZ RAMÍREZ
MMANUEL LUCAS
MANUEL LUCAS
PQP. V. Quiles
P. V. Quiles
Solar-powered air conditioners offer a high potential for energy-efficient cooling with a high economic feasibility. They can significantly reduce the energy consumption in the building sector, which is essential to meet the greater ambition of reducing greenhouse gas emissions by 80% in the EU by 2050. This paper presents a computational model development capable of simulating the behaviour of a photovoltaic-assisted heat pump in different locations and working conditions. In addition, this model has been used to optimise a solar on-grid air conditioning system. The generated model has been validated with experimental data obtained in a real facility for a whole summer of operation (more than 100 tested days) in a Mediterranean climate (Alicante, Spain). According to the simulation results, the average Energy Efficiency Ratio (EER) of the system is 16.0, 10.7 and 7.8 in Barcelona, Madrid and Seville, respectively. The optimisation analysis has proven that the severity of the climatic region increases the costs as well as the optimum PV power to drive the AC unit. The obtained values for the the PV power and the annualised cost are 400 W and 506.2 € for Barcelona, 900 W and 536.7 € for Madrid, and 1300 W and 564.7 € for Seville. The annualised cost and the CO2 emission levels are higher for the conventional system (no PV panels) than for the solar on-grid system, regardless of the installed PV power. This difference can be up to 66.64 € (10.55%) and 112.94 kg CO2 (64.83%) per summer season in the case of Seville.

6 March 2024 in Applied Thermal Engineering
Verified
Journal Article
Open access
JAVIER RUIZ RAMÍREZJAVIER RUIZ RAMÍREZ
JAVIER RUIZ RAMÍREZ
PMPedro Martínez
Pedro Martínez
FVFrancisco Javier Aguilar Valero
Francisco Javier Aguilar Valero
MMANUEL LUCAS
MANUEL LUCAS

5 May 2024 in Applied Thermal Engineering
Verified
Journal Article
Open access
PMPedro Martínez
Pedro Martínez
MMANUEL LUCAS
MANUEL LUCAS
FVFrancisco Javier Aguilar Valero
Francisco Javier Aguilar Valero
JAVIER RUIZ RAMÍREZJAVIER RUIZ RAMÍREZ
JAVIER RUIZ RAMÍREZ
PQP.V. Quiles
P.V. Quiles

21 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
FVFrancisco Javier Aguilar Valero
Francisco Javier Aguilar Valero
DLDamian Crespi Llorens
Damian Crespi Llorens
SAS. Aledo
S. Aledo
PQP. V. Quiles
P. V. Quiles
The current work presents a computationally cost-effective numerical model that successfully simulates a heat pump water heater (HPWH) under typical working conditions of dwellings. The model’s main components are a stratified tank and the heat-pump unit. Both systems are coupled, since a good prediction of water temperature is needed to accurately predict the heat-pump performance. Ten thermocouples measured the tank wall temperature. Measurements and simulations were performed under challenging conditions of a heavy stratification. The 190 L tank stratification was successfully modeled employing a 1D model, experimentally adjusted by three tapping cycles, with 6 × 22, 6 × 33, and 3 × 33 L consumptions, covering flowrates of 4 and 6 L/min. Water temperature is obtained with an uncertainty of 2.6 °C while the heat-pump was ON. A black box model has been used to obtain the heat-pump performance out of the external and condenser temperatures. For the analyzed days, the COP estimation presents an uncertainty of only 5.1%. Finally, an application example is included. It was used to simulate six tapping cycles of the European standard for heat pump water heaters testing (EN 16147). The results show the possibilities for heat-pump manufacturers of applying this calibrated model to predict the performance of HPWHs under different conditions.