Tsung-Yu Yen

Dr. Tsung-Yu Yen

Mackay Memorial Hospital, Hsinchu, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Medicine
Verified
Journal Article
Open access
TYTsung-Yu Yen
Tsung-Yu Yen
JCJeng-Fong Chiou
Jeng-Fong Chiou
WCWei-Yong Chiang
Wei-Yong Chiang
WSWen-Hao Su
Wen-Hao Su
MHMing-Yuan Huang
Ming-Yuan Huang
YLYuen-Liang Lai
Yuen-Liang Lai
The management of breakthrough pain (BTP) in cancer patients is a challenge. It is clinically useful to evaluate the effectiveness of rapid-onset opioid at a starting dose in proportional to the background opioid regimen. This open-label, multicenter, noncomparative study aimed to assess the efficacy and safety of proportional doses of fentanyl buccal soluble film (FBSF) in patients with breakthrough cancer pain. Thirty patients aged 20 to 70, experiencing 1 to 3 BTP per day, receiving regimens equivalent to 60 to 360 mg/day of oral morphine or 25 to 150 μg/h of transdermal fentanyl ≥1 week, were prospectively recruited. FBSF was administered proportionally based on their current opioid regimen for baseline pain. The percentage of patients requiring dose titration was evaluated. For each BTP episode, changes in pain intensity at 30 minutes (PID30) after dosing, patient's satisfaction, the percentage of episodes requiring rescue medication, and adverse events (AEs) were recorded. The percentage of patients who required dose titration was 21.4% (6/28) and 12.0% (3/25) in the full analysis set and per-protocol populations, respectively. The average PID30 was 3.9, and a pain score ≤3 was achieved in 95.1% of the events. Eight out of 367 (2.2%) BTP episodes needed rescue medication. The majority of subjects (75.8%) rated their experience of pain management as good to excellent. A total of 6 drug-related AEs were reported by 3 (10.7%) patients in the safety population. FBSF dose in proportional to the regimen of opioid for baseline pain management is efficacious and well tolerated for the treatment of cancer patients with BTP.
1

12 April 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TYTsung-Yu Yen
Tsung-Yu Yen
KCKai-Cheng Chuang
Kai-Cheng Chuang
HFHsiao-Mei Fu
Hsiao-Mei Fu
CFChen-Ju Feng
Chen-Ju Feng
KLKe-Yu Lien
Ke-Yu Lien
SHShih-Ming Hsu
Shih-Ming Hsu
To develop a method of estimating surface dose in whole breast irradiation, we used an anthropomorphic phantom with accessories for the simulation of different breast sizes. The surface points, which are measured by TLDs, are set along with two main directions, superior-inferior and medial-lateral. The incident angle between the photon beam and the surface and the doses at 1 cm beneath the surface at every point are assessed by a computerized treatment planning system (cTPS). With the prescription dose of 200 cGy, the average surface doses under tangential irradiation are 97.73 (±14.96) cGy, 99.90 (±10.73) cGy, and 105.26 (±9.21) cGy for large, medium, and small breast volumes, respectively. The surface dose increased in the model of small breast volume without significance (p = 0.39). The linear analysis between surface dose and the incident angle is y = 0.5258x + 69.648, R2 = 0.7131 (x: incident angle and y: surface dose). We develop the percentage of skin surface dose with reference to a depth of 1 cm (PSDR1cm) to normalize the inhomogeneous dose. The relationship between incident angle and PSDR1cm is y = 0.1894x + 36.021, R2 = 0.6536 (x: incident angle and y: PSDR1cm) by linear analysis. In conclusion, the surface dose in whole breast irradiation could be estimated from this linear relationship between PSDR1cm and incident angle in daily clinical practice by cTPS. Further in vivo data should be studied to verify this formula.

24 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MLMuh-Lii Liang
Muh-Lii Liang
TYTing-Chi Yeh
Ting-Chi Yeh
MHMan-Hsu Huang
Man-Hsu Huang
PWPao-Shu Wu
Pao-Shu Wu
SWShih-Pei Wu
Shih-Pei Wu
THTsung-Han Hsieh
Tsung-Han Hsieh
Primary intracranial ependymoma is a challenging tumor to treat despite the availability of multidisciplinary therapeutic modalities, including surgical resection, radiotherapy, and adjuvant chemotherapy. After the completion of initial treatment, when resistant tumor cells recur, salvage therapy needs to be carried out with a more precise strategy. Circulating tumor cells (CTCs) have specifically been detected and validated for patients with primary or recurrent diffused glioma. The CTC drug screening platform can be used to perform a mini-invasive liquid biopsy for potential drug selection. The validation of potential drugs in a patient-derived xenograft (PDX) mouse model based on the same patient can serve as a preclinical testing platform. Here, we present the application of a drug testing model in a six-year-old girl with primary ependymoma on the posterior fossa, type A (EPN-PFA). She suffered from tumor recurrence with intracranial and spinal seeding at 2 years after her first operation and extraneural metastases in the pleura, lung, mediastinum, and distant femoral bone at 4 years after initial treatment. The CTC screening platform results showed that everolimus and entrectinib could be used to decrease CTC viability. The therapeutic efficacy of these two therapeutic agents has also been validated in a PDX mouse model from the same patient, and the results showed that these two therapeutic agents significantly decreased tumor growth. After precise drug screening and the combination of focal radiation on the femoral bone with everolimus chemotherapy, the whole-body bone scan showed significant shrinkage of the metastatic tumor on the right femoral bone. This novel approach can combine liquid biopsy, CTC drug testing platforms, and PDX model validation to achieve precision medicine in rare and challenging tumors with extraneural metastases.

14 June 2024 in BMC Palliative Care
Verified
Journal Article
Open access
PDF file
YCYi-Hao Chiang
Yi-Hao Chiang
CLChing-Ting Lien
Ching-Ting Lien
WSWen-Hao Su
Wen-Hao Su
TYTsung-Yu Yen
Tsung-Yu Yen
YCYu-Jen Chen
Yu-Jen Chen
YLYi-Shing Leu
Yi-Shing Leu
Clinical evidence for the rapidity and effectiveness of fentanyl buccal soluble film (FBSF) in reducing pain intensity of breakthrough cancer pain (BTcP) remains inadequate. This study aimed to evaluate the efficacy of FBSF proportional to the around-the‐clock (ATC) opioid regimens in rapidly relieving the intensity of BTcP episodes by determining the percentage of patients requiring further dose titration. The study procedure included a dose-finding period followed by a 14-day observation period. Pain intensity was recorded with a Numeric Rating Scale (NRS) at onset and 5, 10, 15, and 30 min after FBSF self-administration. Meaningful pain relief was defined as the final NRS score ≤ 3. Satisfaction survey was conducted for each patient after treatment using the Global Satisfaction Scale. A total of 63 BTcP episodes occurred in 30 cancer patients. Only one patient required rescue medication at first BTcP episode and then achieved meaningful pain relief after titrating FBSF by 200 µg. Most BTcP episodes relieved within 10 min. Of 63 BTcP episodes, 30 (47.6%), 46 (73.0%), and 53 (84.1%) relieved within 5, 10, and 15 min after FBSF administration. Only grade 1/2 adverse events were reported, including somnolence, malaise, and dizziness. Of the 63 BTcP episodes, 82.6% were rated as excellent/good satisfaction with FBSF. FBSF can be administrated “on demand” by cancer patients at the onset of BTcP, providing rapid analgesia by achieving meaningful pain relief within 10 min. This study was retrospectively registered 24 December, 2021 at Clinicaltrial.gov (NCT05209906): https://clinicaltrials.gov/study/NCT05209906 .

31 January 2025 in Journal of Neuro-Oncology
Verified
Journal Article
Closed access
PDF file
JHJia-Yun Huang
Jia-Yun Huang
TYTing-Chi Yeh
Ting-Chi Yeh
HLHsi-Che Liu
Hsi-Che Liu
JHJen-Yin Hou
Jen-Yin Hou
TYTsung-Yu Yen
Tsung-Yu Yen
MLMuh-Lii Liang
Muh-Lii Liang

21 February 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
YYYing-Hao Yu
Ying-Hao Yu
TYTsung-Yu Yen
Tsung-Yu Yen
SHShih-Kai Hung
Shih-Kai Hung
SCShi-He Chen
Shi-He Chen
KWKuei-Ying Wang
Kuei-Ying Wang
In modern radiation therapy for lung cancer, examining the uncertainty between tumor motion and beam delivery is vitally important. To lower the radiation dose delivery to the patient’s normal tissue, narrowing the irradiation field margin to hit the tumor accurately is critical. Thus we proposed a phantom that simulates the thorax and lung tumor’s motions by employing a 3D printing technique. The lung tumor is controlled by a linear miniature Delta robot arm, with a maximum displacement of 20 mm in each direction. When we simulated the thoracic breathing movements at 12 mm in A–P (Anterior-Posterior), the control errors were within 10%. The average tracking errors of the prosthetic tumor were within 1.1 mm. Therefore, the 3D-printed phantom with a robot arm can provide a reliable simulation for training and dosimetry measurement before lung radiotherapy, especially SBRT.