Shih-Ming Hsu

Prof. Shih-Ming Hsu


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2023 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
CLChih-Yuan Lin
Chih-Yuan Lin
LCLin-Shan Chou
Lin-Shan Chou
YWYuan-Hung Wu
Yuan-Hung Wu
JKJohn S. Kuo
John S. Kuo
MMMinesh P. Mehta
Minesh P. Mehta
TWTi-Hao Wang
Ti-Hao Wang

1 October 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
JLJia-Cheng Lee
Jia-Cheng Lee
YCYi-Wei Chen
Yi-Wei Chen
KCKeh-Shih Chuang
Keh-Shih Chuang
FHFang-Yuh Hsu
Fang-Yuh Hsu
FCFong-In Chou
Fong-In Chou
YWyuanhung wu
yuanhung wu
Unlike conventional photon radiotherapy, sophisticated patient positioning tools are not available for boron neutron capture therapy (BNCT). Thus, BNCT remains vulnerable to setup errors and intra-fractional patient motion. The aim of this study was to estimate the impact of deviations in positioning on the dose administered by BNCT for brain tumors at the Tsing Hua open-pool reactor (THOR). For these studies, a simulated head model was generated based on computed tomography (CT) images of a patient with a brain tumor. A cylindrical brain tumor 3 cm in diameter and 5 cm in length was modeled at distances of 6.5 cm and 2.5 cm from the posterior scalp of this head model (T6.5 cm and T2.5 cm, respectively). Radiation doses associated with positioning errors were evaluated for each distance, including left and right shifts, superior and inferior shifts, shifts from the central axis of the beam aperture, and outward shifts from the surface of the beam aperture. Rotational and tilting effects were also evaluated. The dose prescription was 20 Gray-equivalent (Gy-Eq) to 80 % of the tumor. The treatment planning system, NCTPlan, was used to perform dose calculations. The average decreases in mean tumor dose for T6.5 cm for the 1 cm, 2 cm, and 3 cm lateral shifts composed by left, right, superior, and inferior sides, were approximately 1 %, 6 %, and 11 %, respectively, compared to the dose administered to the initial tumor position. The decreases in mean tumor dose for T6.5 cm were approximately 5 %, 11 %, and 15 % for the 1 cm, 2 cm, and 3 cm outward shifts, respectively. For a superficial tumor at T2.5cm, no significant decrease in average mean tumor dose was observed following lateral shifts of 1 cm. Rotational and tilting up to 15° did not result in significant difference to the tumor dose. Dose differences to the normal tissues as a result of the shifts in positioning were also minimal. Taken together, these data demonstrate that the mean dose administered to tumors at greater depths is potentially more vulnerable to deviations in positioning, and greater shift distances resulted in reduced mean tumor doses at the THOR. Moreover, these data provide an estimation of dose differences that are caused by setup error or intra-fractional motion during BNCT, and these may facilitate more accurate predictions of actual patient dose in future treatments.

7 May 2024 in Cancers
Verified
Journal Article
Open access
PDF file
HCHo-Da Chuang
Ho-Da Chuang
YLYu-Hung Lin
Yu-Hung Lin
CLChin-hsiung Lin
Chin-hsiung Lin
YLYuan-Chun Lai
Yuan-Chun Lai
CWChin-Hui Wu
Chin-Hui Wu
SHShih-Ming Hsu
Shih-Ming Hsu
This study uses Monte Carlo simulation and experimental measurements to develop a predictive model for estimating the external dose rate associated with permanent radioactive source implantation in prostate cancer patients. The objective is to estimate the accuracy of the patient’s external dose rate measurement. First, I-125 radioactive sources were implanted into Mylar window water phantoms to simulate the permanent implantation of these sources in patients. Water phantom experimental measurement was combined with Monte Carlo simulation to develop predictive equations, whose performance was verified against external clinical data. The model’s accuracy in predicting the external dose rate in patients with permanently implanted I-125 radioactive sources was high (R2 = 0.999). A comparative analysis of the experimental measurements and the Monte Carlo simulations revealed that the maximum discrepancy between the measured and calculated values for the water phantom was less than 5.00%. The model is practical for radiation safety assessments, enabling the evaluation of radiation exposure risks to individuals around patients with permanently implanted I-125 radioactive sources.

12 April 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TYTsung-Yu Yen
Tsung-Yu Yen
KCKai-Cheng Chuang
Kai-Cheng Chuang
HFHsiao-Mei Fu
Hsiao-Mei Fu
CFChen-Ju Feng
Chen-Ju Feng
KLKe-Yu Lien
Ke-Yu Lien
SHShih-Ming Hsu
Shih-Ming Hsu
To develop a method of estimating surface dose in whole breast irradiation, we used an anthropomorphic phantom with accessories for the simulation of different breast sizes. The surface points, which are measured by TLDs, are set along with two main directions, superior-inferior and medial-lateral. The incident angle between the photon beam and the surface and the doses at 1 cm beneath the surface at every point are assessed by a computerized treatment planning system (cTPS). With the prescription dose of 200 cGy, the average surface doses under tangential irradiation are 97.73 (±14.96) cGy, 99.90 (±10.73) cGy, and 105.26 (±9.21) cGy for large, medium, and small breast volumes, respectively. The surface dose increased in the model of small breast volume without significance (p = 0.39). The linear analysis between surface dose and the incident angle is y = 0.5258x + 69.648, R2 = 0.7131 (x: incident angle and y: surface dose). We develop the percentage of skin surface dose with reference to a depth of 1 cm (PSDR1cm) to normalize the inhomogeneous dose. The relationship between incident angle and PSDR1cm is y = 0.1894x + 36.021, R2 = 0.6536 (x: incident angle and y: PSDR1cm) by linear analysis. In conclusion, the surface dose in whole breast irradiation could be estimated from this linear relationship between PSDR1cm and incident angle in daily clinical practice by cTPS. Further in vivo data should be studied to verify this formula.

30 June 2022 in Cancers
Verified
Journal Article
Open access
PDF file
CCChiu-Ping Chen
Chiu-Ping Chen
CLChi-Yeh Lin
Chi-Yeh Lin
CKChia-Chun Kuo
Chia-Chun Kuo
TCTung-Ho Chen
Tung-Ho Chen
SLShao-Chen Lin
Shao-Chen Lin
SHShih-Ming Hsu
Shih-Ming Hsu
Purpose: Breast immobilization with personalized breast holder (PERSBRA) is a promising approach for normal organ protection during whole breast radiotherapy. The aim of this study is to evaluate the skin surface dose for breast radiotherapy with PERSBRA using different radiotherapy techniques. Materials and methods: We designed PERSBRA with three different mesh sizes (large, fine and solid) and applied them on an anthropomorphic(Rando) phantom. Treatment planning was generated using hybrid, intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques to deliver a prescribed dose of 5000 cGy in 25 fractions accordingly. Dose measurement with EBT3 film and TLD were taken on Rando phantom without PERSBRA, large mesh, fine mesh and solid PERSBRA for (a) tumor doses, (b) surface doses for medial field and lateral field irradiation undergoing hybrid, IMRT, VMAT techniques. Results: The tumor dose deviation was less than five percent between the measured doses of the EBT3 film and the TLD among the different techniques. The application of a PERSBRA was associated with a higher dose of the skin surface. A large mesh size of PERSBRA was associated with a lower surface dose. The findings were consistent among hybrid, IMRT, or VMAT techniques. Conclusions: Breast immobilization with PERSBRA can reduce heart toxicity but leads to a build-up of skin surface doses, which can be improved with a larger mesh design for common radiotherapy techniques.

31 July 2025 in Journal of Neuro-Oncology
Verified
Journal Article
Open access
PDF file
TLTien-Li Lan
Tien-Li Lan
CLChun-Fu Lin
Chun-Fu Lin
YLYi-Yen Lee
Yi-Yen Lee
FCFeng-Chi Chang
Feng-Chi Chang
SLShih-Chieh Lin
Shih-Chieh Lin
Yi-Wei ChenYi-Wei Chen
Yi-Wei Chen
Background: Boron neutron capture therapy (BNCT) is a targeted radiotherapy modality that has shown promise in the treatment of recurrent gliomas and head and neck cancers. Although meningiomas are generally slow-growing, recent studies have demonstrated favorable uptake of boron-containing compounds, particularly boronophenylalanine (BPA), suggesting a potential role for BNCT in recurrent meningioma. Methods: We retrospectively analyzed 13 patients with recurrent meningiomas treated with salvage BNCT at the Tsing Hua Open-Pool Reactor between August 2020 and May 2024. Tumor uptake was assessed using either ¹⁸F-BPA or ¹⁸F-Fluciclovine PET. Treatment response was evaluated using RANO criteria, and outcomes were analyzed in relation to dosimetric and clinical factors. Results: Of the 13 patients (1 WHO grade 3, 6 grade 2, and 6 grade 1), 5 (38%) responded to BNCT. Responders had significantly higher tumor mean dose (45.10 vs. 25.85 GyE, p = 0.003). Tumor location influenced dosimetry; non–skull base tumors received higher doses and showed a trend toward better response. TNR and tumor size were not predictive of response. No severe adverse events were observed. Conclusions: Salvage BNCT is a feasible and well-tolerated treatment for recurrent meningioma, with dose distribution and tumor location significantly influencing treatment response. Further studies are warranted to refine imaging and planning strategies, particularly for skull base lesions and in the context of Fluciclovine PET.