Leah A. Groves

Dr. Leah A. Groves


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2020 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
LGLeah A. Groves
Leah A. Groves
BVBlake VanBerlo
Blake VanBerlo
NVNatan Veinberg
Natan Veinberg
AAAbdulrahman Alboog
Abdulrahman Alboog
Terry PetersTerry Peters
Terry Peters
Elvis C. S. ChenElvis C. S. Chen
Elvis C. S. Chen

8 May 2019 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
LGLeah A. Groves
Leah A. Groves
PCPatrick Kelly Carnahan
Patrick Kelly Carnahan
DADaniel R. Allen
Daniel R. Allen
RARankin Adam
Rankin Adam
Terry PetersTerry Peters
Terry Peters
Elvis C. S. ChenElvis C. S. Chen
Elvis C. S. Chen

7 January 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
LGLeah A. Groves
Leah A. Groves
NLNatalie Li
Natalie Li
Terry PetersTerry Peters
Terry Peters
Elvis C. S. ChenElvis C. S. Chen
Elvis C. S. Chen
While ultrasound (US) guidance has been used during central venous catheterization to reduce complications, including the puncturing of arteries, the rate of such problems remains non-negligible. To further reduce complication rates, mixed-reality systems have been proposed as part of the user interface for such procedures. We demonstrate the use of a surgical navigation system that renders a calibrated US image, and the needle and its trajectory, in a common frame of reference. We compare the effectiveness of this system, whereby images are rendered on a planar monitor and within a head-mounted display (HMD), to the standard-of-care US-only approach, via a phantom-based user study that recruited 31 expert clinicians and 20 medical students. These users performed needle-insertions into a phantom under the three modes of visualization. The success rates were significantly improved under HMD-guidance as compared to US-guidance, for both expert clinicians (94% vs. 70%) and medical students (70% vs. 25%). Users more consistently positioned their needle closer to the center of the vessel’s lumen under HMD-guidance compared to US-guidance. The performance of the clinicians when interacting with this monitor system was comparable to using US-only guidance, with no significant difference being observed across any metrics. The results suggest that the use of an HMD to align the clinician’s visual and motor fields promotes successful needle guidance, highlighting the importance of continued HMD-guidance research.

20 June 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LGLeah A. Groves
Leah A. Groves
MKMohamed Keita
Mohamed Keita
STSaidou Talla
Saidou Talla
RKRon Kikinis
Ron Kikinis
GFGabor Fichtinger
Gabor Fichtinger
MCMamadou Camara
Mamadou Camara
Ultrasound-compatible phantoms are used to develop novel US-based systems and train simulated medical interventions. The price difference between lab-made and commercially available ultrasound-compatible phantoms lead to the publication of many papers categorized as low-cost in the literature. The aim of this review was to improve the phantom selection process by summarizing the pertinent literature. We compiled papers on US-compatible spine, prostate, vascular, breast, kidney, and li ver phantoms. We reviewed papers for cost and accessibility, providing an overview of the materials, construction time, shelf life, needle insertion limits, and manufacturing and evaluation methods. This information was summarized by anatomy. The clinical application associated with each phantom was also reported for those interested in a particular intervention. Techniques and common practices for building low-cost phantoms were provided. Overall, this paper aims to summarize a breadth of ultrasound-compatible phantom research to enable informed phantom methods selection.

2 December 2019 in Healthcare Technology Letters
Verified
Journal Article
Open access
PDF file
LGLeah A. Groves
Leah A. Groves
BVBlake VanBerlo
Blake VanBerlo
TPTerry M. Peters
Terry M. Peters
Elvis C. S. ChenElvis C. S. Chen
Elvis C. S. Chen
The authors present a deep learning algorithm for the automatic centroid localisation of out‐of‐plane US needle reflections to produce a semi‐automatic ultrasound (US) probe calibration algorithm. A convolutional neural network was trained on a dataset of 3825 images at a 6 cm imaging depth to predict the position of the centroid of a needle reflection. Applying the automatic centroid localisation algorithm to a test set of 614 annotated images produced a root mean squared error of 0.62 and 0.74 mm (6.08 and 7.62 pixels) in the axial and lateral directions, respectively. The mean absolute errors associated with the test set were 0.50 ± 0.40 mm and 0.51 ± 0.54 mm (4.9 ± 3.96 pixels and 5.24 ± 5.52 pixels) for the axial and lateral directions, respectively. The trained model was able to produce visually validated US probe calibrations at imaging depths on the range of 4–8 cm, despite being solely trained at 6 cm. This work has automated the pixel localisation required for the guided‐US calibration algorithm producing a semi‐automatic implementation available open‐source through 3D Slicer. The automatic needle centroid localisation improves the usability of the algorithm and has the potential to decrease the fiducial localisation and target registration errors associated with the guided‐US calibration method.

10 October 2019
Verified
Book Chapter
Closed access
PDF file
LGLeah A. Groves
Leah A. Groves
NLNatalie Li
Natalie Li
Terry PetersTerry Peters
Terry Peters
Elvis C. S. ChenElvis C. S. Chen
Elvis C. S. Chen