Mamadou Samba Camara

Mamadou Samba Camara

Auto-generated profile, based on publicly available information

Mamadou Samba Camara

Cheikh Anta Diop University,Laboratoire dImagerie Mdicale et Bio-Informatique Polytechnic High School,Dakar,Senegal

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LGLeah A. Groves
Leah A. Groves
MKMohamed Keita
Mohamed Keita
STSaidou Talla
Saidou Talla
RKRon Kikinis
Ron Kikinis
GFGabor Fichtinger
Gabor Fichtinger
MCMamadou Camara
Mamadou Camara
Ultrasound-compatible phantoms are used to develop novel US-based systems and train simulated medical interventions. The price difference between lab-made and commercially available ultrasound-compatible phantoms lead to the publication of many papers categorized as low-cost in the literature. The aim of this review was to improve the phantom selection process by summarizing the pertinent literature. We compiled papers on US-compatible spine, prostate, vascular, breast, kidney, and li ver phantoms. We reviewed papers for cost and accessibility, providing an overview of the materials, construction time, shelf life, needle insertion limits, and manufacturing and evaluation methods. This information was summarized by anatomy. The clinical application associated with each phantom was also reported for those interested in a particular intervention. Techniques and common practices for building low-cost phantoms were provided. Overall, this paper aims to summarize a breadth of ultrasound-compatible phantom research to enable informed phantom methods selection.

20 April 2020
Verified
Book Chapter
Open access
PDF file
FGFrançois Kasséné Gomis
François Kasséné Gomis
TBThierry Bouwmans
Thierry Bouwmans
MCMamadou Samba Camara
Mamadou Samba Camara
IDIdy Diop
Idy Diop
Steganography is a science which helps to hide secret data inside multimedia supports like image, audio and video files to ensure secure communication between two parts of a channel. Steganalysis is the discipline which detects the presence of data hidden by a steganographic algorithm. There are two types of steganalysis: targeted steganalysis and universal steganalysis. In targeted steganalysis, the steganographic algorithm used to hide data is known. In the case of universal steganalysis, the detection of hidden data doesn’t depend on any specific algorithm used in the process of steganography. In this paper, we focus on universal steganalysis of images in a database with an eventual cover-source mismatch problem. It is shown that combining both unsupervised and supervised machine learning algorithms helps to improve the performance of classifiers in the case of universal steganalysis by reducing the cover-source mismatch problem. In the unsupervised step, the k-means algorithm is generally used to group similar images. When the number of features extracted from the image is very large it becomes difficult to compute the k-means algorithm properly. We propose, in that case, to use Deep Learning with Convolutional Neural Network (CNN) to group similar images at first and implement a Multilayer Perceptron (MLP) neural network to estimate the hidden message length in all the different groups of images. The first step of this approach prevents the cover-source mismatch problem. Reducing this issue boost the performance of classifiers in the second step which consists of estimating the hidden message length.

19 July 2023
Verified
Conference Paper
Closed access
FNFatou Bintou Ndiaye
Fatou Bintou Ndiaye
LGLeah A. Groves
Leah A. Groves
RHRebecca Hisey
Rebecca Hisey
TUTamas Ungi
Tamas Ungi
IDIdy Diop
Idy Diop
MCMamadou Samba Camara
Mamadou Samba Camara
Background and purpose: Nowadays, computerized nephrostomy techniques exist. Although relatively safe, several factors make it difficult for inexperienced users. A computer-assisted nephrostomy guidance system has been studied to increase the success rate of this intervention and reduce the work and difficulties encountered by the actors. Methods: To design the system, two methods will be studied. Following this study, this system was designed based on method 2. SmartSysNephro is composed of a hardware part whose manipulations made by the user are visualized and assisted by the computer. This nephrostomy procedure that the user simulates is monitored by webcam. Using the data from this Intel Real Sense webcam, allowed to propose a CNN YOLO model. Results: The results obtained show that the objectives set have been achieved globally. The SmartSysNephro system gives real time warning when the surgeon deviates from the standard workflow. It allows monitoring of the nephrostomy procedure via webcam. It is therefore relying on tracking, and it also has the potential to identify workflow tasks in video using the YOLO model. Conclusion: SmartSysNephro shows that the skills of the users can be greatly improved during the intervention because they will benefit from the assistance of the end-to-end system. Therefore, the success rate of nephrostomy increases, and the difficulties encountered by the actors decrease considerably.