In the framework of the EUROfusion Horizon Europe Programme, ENEA and its linked third parties are in charge of the conceptual design of the steam generators belonging to EU DEMO WCLL Breeding Blanket Primary Heat Transfer Systems (BB PHTSs). In particular, in 2021, design activities and supporting numerical simulations were carried out in order to achieve a feasible and robust preliminary concept design of the Once Through Steam Generators (OTSGs), selected as reference technology for the DEMO Balance of Plant at the end of the Horizon 2020 Programme. The design of these components is very challenging. In fact, the steam generators have to deliver the thermal power removed from the two principal blanket subsystems, i.e., the First Wall (FW) and the Breeding Zone (BZ), to the Power Conversion System (PCS) for its conversion into electricity, operating under plasma pulsed regime and staying in dwell period at a very low power level (decay power). Consequently, the OTSG stability and control represent a key point for these systems’ operability and the success of a DEMO BoP configuration with direct coupling between the BB PHTS and the PCS. In this paper, the authors reported and critically discussed the FW and BZ steam generators’ thermal-hydraulic and mechanical design, the developed 3D CAD models, as well as the main results of the stability analyses and the control strategy to be adopted.
Recent R&D activities in nuclear fusion have identified the DEMO reactor as the ITER successor, aiming at demonstrating the technical feasibility of fusion plants, along with their commercial exploitation. However, the pulsed operation of the machine causes an “unconventional” operation of the system, posing unique challenges to the functional feasibility of the steam generator, for which it is necessary to define and qualify a reference configuration for DEMO. In order to facilitate the transitions between different operational regimes, the Once Through Steam Generator (OTSG) is considered to be a suitable choice for the DEMO primary heat transfer systems, being characterized by lower thermal inertia with respect to the most common U-tube steam generators. In this framework, the ENEA has undertaken construction of the STEAM facility at Brasimone R.C., aiming at characterizing the behavior of the DEMO OTSG and related water coolant systems in steady-state and transient conditions. A dedicated OTSG mock-up has been conceived and designed, adopting a scaling procedure, keeping the height 1:1 of the DEMO OTSGs. The conceptual design has been supported by RELAP5/Mod3.3 thermal-hydraulic calculations. CFD and FEM codes have been used for fluid-dynamic analyses and mechanical stress analyses, respectively, in specific parts of the component.