Kiattisak Promsuwan

Dr. Kiattisak Promsuwan

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2022 in Talanta
Verified
Journal Article
Closed access
KSKritsada Samoson
Kritsada Samoson
ASAsamee Soleh
Asamee Soleh
KSKasrin Saisahas
Kasrin Saisahas
KPKiattisak Promsuwan
Kiattisak Promsuwan
JSJenjira Saichanapan
Jenjira Saichanapan
WLWarakorn Limbut
Warakorn Limbut

1 May 2021 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
KSKasrin Saisahas
Kasrin Saisahas
ASAsamee Soleh
Asamee Soleh
KPKiattisak Promsuwan
Kiattisak Promsuwan
APApichai Phonchai
Apichai Phonchai
NSNabeesathul Sumayya Mohamed Sadiq
Nabeesathul Sumayya Mohamed Sadiq
WLWarakorn Limbut
Warakorn Limbut

11 January 2023 in Talanta
Verified
Journal Article
Closed access
KPKiattisak Promsuwan
Kiattisak Promsuwan
ASAsamee Soleh
Asamee Soleh
KSKritsada Samoson
Kritsada Samoson
KSKasrin Saisahas
Kasrin Saisahas
SWSangay Wangchuk
Sangay Wangchuk
WLWarakorn Limbut
Warakorn Limbut

12 April 2022 in ACS Omega
Verified
Journal Article
Open access
KSKasrin Saisahas
Kasrin Saisahas
ASAsamee Soleh
Asamee Soleh
KPKiattisak Promsuwan
Kiattisak Promsuwan
JSJenjira Saichanapan
Jenjira Saichanapan
APApichai Phonchai
Apichai Phonchai
WLWarakorn Limbut
Warakorn Limbut
A portable electrochemical device for xylazine detection is presented for the first time. An electrochemical paper-based analytical device (ePAD) was integrated with a smartphone. The fabrication of the ePAD involved wax printing, low-tack transfer tape, and cutting and screen-printing techniques. Graphene ink was coated on the substrate and modified with nanocoral-like polyaniline, providing an electron transfer medium with a larger effective surface area that promoted charge transfer. The conductive ink on the ePAD presented a thickness of 25.0 ± 0.9 μm for an effective surface area of 0.374 cm2. This sensor was then tested directly on xylazine using differential pulse voltammetry. Two linear responses were obtained: from 0.2 to 5 μg mL–1 and from 5 to 100 μg mL–1. The detection limit was 0.06 μg mL–1. Reproducibility was tested on 10 preparations. The relative standard deviation was less than 5%. The applicability of the sensor was evaluated with beverage samples spiked with trace xylazine. Recoveries ranged from 84 ± 4 to 105 ± 2%. The developed sensor demonstrated excellent accuracy in the detection of trace xylazine. It would be possible to develop the portable system to detect various illicit drugs to aid forensic investigations.

28 December 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
KSKasrin Saisahas
Kasrin Saisahas
ASAsamee Soleh
Asamee Soleh
SSSunita Somsiri
Sunita Somsiri
PSPatthamaporn Senglan
Patthamaporn Senglan
KPKiattisak Promsuwan
Kiattisak Promsuwan
WLWarakorn Limbut
Warakorn Limbut
A 3D porous graphene structure was directly induced by CO2 laser from the surface of Kapton tape (carbon source) supported by polyethylene terephthalate (PET) laminating film. A highly flexible laser-induced porous graphene (LI-PGr) electrode was then fabricated via a facile one-step method without reagent and solvent in a procedure that required no stencil mask. The method makes pattern design easy, and production cost-effective and scalable. We investigated the performance of the LI-PGr electrode for the detection of methamphetamine (MA) on household surfaces and in biological fluids. The material properties and morphology of LI-PGr were analysed by scanning electron microscopy (SEM), energy dispersive x-ray (EDX) and Raman spectroscopy. The LI-PGr electrode was used as the detector in a portable electrochemical sensor, which exhibited a linear range from 1.00 to 30.0 µg mL−1 and a detection limit of 0.31 µg mL−1. Reproducibility was good (relative standard deviation of 2.50% at 10.0 µg mL−1; n = 10) and anti-interference was excellent. The sensor showed good precision and successfully determined MA on household surfaces and in saliva samples.

1 September 2021 in Journal of Colloid and Interface Science
Verified
Journal Article
Closed access
KPKiattisak Promsuwan
Kiattisak Promsuwan
ASAsamee Soleh
Asamee Soleh
KSKasrin Saisahas
Kasrin Saisahas
JSJenjira Saichanapan
Jenjira Saichanapan
PKProespichaya Kanatharana
Proespichaya Kanatharana
WLWarakorn Limbut
Warakorn Limbut