Asamee Soleh

Mr. Asamee Soleh

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2022 in Talanta
Verified
Journal Article
Closed access
KSKritsada Samoson
Kritsada Samoson
ASAsamee Soleh
Asamee Soleh
KSKasrin Saisahas
Kasrin Saisahas
KPKiattisak Promsuwan
Kiattisak Promsuwan
JSJenjira Saichanapan
Jenjira Saichanapan
WLWarakorn Limbut
Warakorn Limbut

1 May 2021 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
KSKasrin Saisahas
Kasrin Saisahas
ASAsamee Soleh
Asamee Soleh
KPKiattisak Promsuwan
Kiattisak Promsuwan
APApichai Phonchai
Apichai Phonchai
NSNabeesathul Sumayya Mohamed Sadiq
Nabeesathul Sumayya Mohamed Sadiq
WLWarakorn Limbut
Warakorn Limbut

11 January 2023 in Talanta
Verified
Journal Article
Closed access
KPKiattisak Promsuwan
Kiattisak Promsuwan
ASAsamee Soleh
Asamee Soleh
KSKritsada Samoson
Kritsada Samoson
KSKasrin Saisahas
Kasrin Saisahas
SWSangay Wangchuk
Sangay Wangchuk
WLWarakorn Limbut
Warakorn Limbut

28 December 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
KSKasrin Saisahas
Kasrin Saisahas
ASAsamee Soleh
Asamee Soleh
SSSunita Somsiri
Sunita Somsiri
PSPatthamaporn Senglan
Patthamaporn Senglan
KPKiattisak Promsuwan
Kiattisak Promsuwan
WLWarakorn Limbut
Warakorn Limbut
A 3D porous graphene structure was directly induced by CO2 laser from the surface of Kapton tape (carbon source) supported by polyethylene terephthalate (PET) laminating film. A highly flexible laser-induced porous graphene (LI-PGr) electrode was then fabricated via a facile one-step method without reagent and solvent in a procedure that required no stencil mask. The method makes pattern design easy, and production cost-effective and scalable. We investigated the performance of the LI-PGr electrode for the detection of methamphetamine (MA) on household surfaces and in biological fluids. The material properties and morphology of LI-PGr were analysed by scanning electron microscopy (SEM), energy dispersive x-ray (EDX) and Raman spectroscopy. The LI-PGr electrode was used as the detector in a portable electrochemical sensor, which exhibited a linear range from 1.00 to 30.0 µg mL−1 and a detection limit of 0.31 µg mL−1. Reproducibility was good (relative standard deviation of 2.50% at 10.0 µg mL−1; n = 10) and anti-interference was excellent. The sensor showed good precision and successfully determined MA on household surfaces and in saliva samples.

1 September 2021 in Journal of Colloid and Interface Science
Verified
Journal Article
Closed access
KPKiattisak Promsuwan
Kiattisak Promsuwan
ASAsamee Soleh
Asamee Soleh
KSKasrin Saisahas
Kasrin Saisahas
JSJenjira Saichanapan
Jenjira Saichanapan
PKProespichaya Kanatharana
Proespichaya Kanatharana
WLWarakorn Limbut
Warakorn Limbut

1 May 2021 in Electrochimica Acta
Verified
Journal Article
Closed access
KPKiattisak Promsuwan
Kiattisak Promsuwan
CKChompoonut Kaewjunlakan
Chompoonut Kaewjunlakan
JSJenjira Saichanapan
Jenjira Saichanapan
ASAsamee Soleh
Asamee Soleh
KSKasrin Saisahas
Kasrin Saisahas
WLWarakorn Limbut
Warakorn Limbut