SAEED AWOD BIN HASSAN

Dr. SAEED AWOD BIN HASSAN

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AAAbdulkhaliq Alshadidi
Abdulkhaliq Alshadidi
Ahid Amer AlshahraniAhid Amer Alshahrani
Ahid Amer Alshahrani
LALujain Ibrahim Aldosari
Lujain Ibrahim Aldosari
SCsaurabh chaturvedi
saurabh chaturvedi
RSRavinder S Singh
Ravinder S Singh
Giuseppe MinerviniGiuseppe Minervini
Giuseppe Minervini
Artificial intelligence (AI) is a contemporary, information-driven innovative technology. Prosthetic dentistry, also known as prosthodontics, is the restoration and reconstruction of missing teeth utilizing implants for permanent and removable prostheses. It enhances healthy soft and hard tissues, promoting oral health. This study examined the use of artificial intelligence in prosthodontics to diagnose abnormalities and create patient-specific prostheses. Two researchers searched Google Scholar, Scopus, PubMed/MEDLINE, EBSCO host, Science Direct, and Web of Science (MEDLINE, WOS, and KJD). Articles on AI in English were reviewed. We also collected the following broad article aspects: research and control groups, assessment methodology, outcomes, and quality rankings. This methodological study examined AI use in prosthodontics using the latest scientific findings. The findings were statistically evaluated using ANOVA. Titles and abstracts revealed 172 AI-related dentistry studies, which were analyzed in this research. Thirty-eight papers were eliminated. According to the evaluation, AI was found to have significantly increased in prosthodontics. Despite the vast number of studies documenting AI applications, the description of the data illustrated the latest breakthroughs in AI in prosthodontics, highlighting its use in automatically produced diagnostics, predicting analytics, and classification or verification tools.

29 August 2023 in Gels
Verified
Journal Article
Open access
PDF file
SASuraj Arora
Suraj Arora
Gotam DasGotam Das
Gotam Das
MAMohammed Alqarni
Mohammed Alqarni
VGVishakha Grover
Vishakha Grover
SBSuheel Manzoor Baba
Suheel Manzoor Baba
AOAnchal Ohri
Anchal Ohri
Biopolymers are organic polymers that can be treated into intricate designs with porous characteristics that mimic essential biologic components. Due to their superior biosafety, biodegradability, biocompatibility, etc., they have been utilized immensely in biomedical engineering, regeneration, and drug delivery. To obtain the greatest number of results, a literature search was undertaken in scientific search engines utilizing keywords. Chitosan is used in a variety of medical sectors, with the goal of emphasizing its applications and benefits in the clinical dental industry. Chitosan can be dissolved in liquid form and combined with other substances to create a variety of products, including fibers, hydrogels, membranes, microspheres, resins, sponges, pastes, tablets, and micro granules. Chitosan has been studied in a variety of dental applications. Chitosan is used in the prevention of caries and wear, in pulpotomy to accelerate osteogenesis in guided tissue regeneration due to its hemostatic property, and primarily to benefit from its antimicrobial activity by adding it to materials, such as glass ionomer cement, calcium hydroxide, and adhesive systems. With its antibacterial activity and biocompatibility, chitosan is leading the pack as a promising ingredient in the production of dental materials. The current review provides an update on the background, fundamentals, and wide range of uses of chitosan and its gels in dental science.

10 July 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
SHSAEED AWOD BIN HASSAN
SAEED AWOD BIN HASSAN
AAAbdulkhaliq Alshadidi
Abdulkhaliq Alshadidi
LALujain Ibrahim Aldosari
Lujain Ibrahim Aldosari
Artak HeboyanArtak Heboyan
Artak Heboyan
RSRavinder S Singh
Ravinder S Singh
Background and objectives: Polyvinyl ether siloxane (PVES) possesses ideal characteristics for making precise and accurate dental impressions. PVES dimensional stability owes to its better polymeric properties derived from its parent materials poly ethers and polyvinyl siloxanes. As recommended use of chemical disinfecting agents is getting more popular, there is a growing concern associated with the effect of disinfectants on PVES dimensional stability. This study was aimed to understand the PVES behavior when subjected to chemical disinfectants. Materials and methodology: The data was collected from research studies retrieved from Google Scholar, Scopus, and PubMed using MeSH terms of keywords “vinyl polyether siloxane AND Disinfection” or (Vinyl polyether siloxane OR polyvinyl siloxane ether OR PVES) AND (disinfectant OR disinfection)” without any restriction to publication date. The PRISMA (Preferred Reporting Items for Systemic Review and Meta-Analysis) directions were observed during the data collection, screening of studies, and meta-analysis. The primary data were retrieved, and batch exported from databases using Harzing’s Publish or Perish software; primary analysis was performed in Microsoft Excel, while statistical analysis for effect size, two-tailed p-values, and heterogeneity among studies was performed using Meta Essentials. The effect size was calculated using Hedge’s g values at the 95% confidence level using the random-effects model. Heterogeneity among studies was measured using the Cochrane Q and I2. Results and conclusion: Dental impressions made from the PVES elastomeric impression materials showed no significant changes in dimensional stability. Immersion in the chemical disinfectant for 10 min was associated with clinically irrelevant changes in the dimensions of the PVES impressions. Disinfection with sodium hypochlorite was associated with clinically significant changes in dimensions, with a two-tailed p-value of 0.049. Disinfection with 2–2.5% glutaraldehyde solution was not associated with any significant dimensional variability.

MAMohammed Alobaid
Mohammed Alobaid
SHSAEED AWOD BIN HASSAN
SAEED AWOD BIN HASSAN
AAAli Alfarhan
Ali Alfarhan
SASalma Ali
Salma Ali
MHMOHAMMAD SHAHUL HAMEED
MOHAMMAD SHAHUL HAMEED
SSSadatullah Syed
Sadatullah Syed
Background: The purpose of the research was to evaluate the content and delivery of the undergraduate endodontic curriculum. Methods: A needs assessment survey was distributed among the Deans of all the dental colleges in Saudi Arabia. Results: The response rate was 72%. All the colleges include foundational and advanced topics in their curriculum. Didactic lectures, clinical cases, self-directed learning assignments and projects, and videos are the most common teaching methods, whereas virtual learning and reading list are the least popular methods. The average staff-to-student ratio for preclinical and clinical training is 1:6 and 1:7, respectively. Eighty-six percent of colleges utilize dedicated endodontic clinics supervised by specialized endodontists. Eighty percent of colleges use simple cases for canal preparation and obturation. Most colleges do not use magnification and ultrasonic instruments. Saline and sodium hypochlorite are preferred irrigation solutions, whereas calcium hydroxide is the preferred inter-visit medicament. Many use MTA as an advanced material, calcium hydroxide as an inter-visit medicament, and provisional restoration after RCT. Conclusion: The content and delivery of the endodontic undergraduate curriculum are primarily uniform. The use of specialist endodontists dedicated endodontic clinics, rotary instruments, and advanced materials have emerged as curricular strengths. However, diversification of teaching strategies, use of magnification instruments, and an increase in the minimum number of endodontically treated teeth are leading areas demanding curricular improvement.

1 January 2024 in Pain Research and Management
Verified
Journal Article
Open access
SHSAEED AWOD BIN HASSAN
SAEED AWOD BIN HASSAN
Aims: The aim of this investigation was to assess bleaching sensitivity following bleaching using either 38% H2O2 only or 38% H2O2 followed by ozone application.Methods: In this randomized controlled clinical investigation, 80 participants (40 females and 40 males) were randomly assigned to two groups (n = 40 each; 20 females and 20 males). The upper anterior teeth were bleached by 38% H2O2 for 20 min followed by ozone application for 60 s (healOzone X4, KaVo Dental, Biberach, Germany) in Group 1 (test group). Meanwhile, the bleaching protocol in Group 2 (controls) included the application of just 38% H2O2 for 20 min. Tooth sensitivity before and after bleaching was reported by the participants using a visual analog scale (VAS) from 0 to 10. Mann–Whitney U test, Wilcoxon signed‐rank test, and regression analysis were used to analyze the data. Significant statistical outcomes were identified at p < 0.05.Results: Bleaching sensitivity was reported following both tested bleaching protocols (p < 0.001). However, less bleaching sensitivity was reported when ozone was applied for 60 s after bleaching with 38% H2O2 (p < 0.001). Female participants reported more bleaching sensitivity regardless the applied bleaching protocol (p < 0.05).Conclusions: Bleaching protocols with 38% hydrogen peroxide were associated with less bleaching sensitivity when followed by ozone application on the teeth.

Verified
Journal Article
Open access
PDF file
HAhanan alsunbul
hanan alsunbul
AKAFTAB Ahmed KHAN
AFTAB Ahmed KHAN
YAYasser M Alqahtani
Yasser M Alqahtani
SHSAEED AWOD BIN HASSAN
SAEED AWOD BIN HASSAN
WAWaleed Asiri
Waleed Asiri
AAAlhanoof Aldegheishem
Alhanoof Aldegheishem
This laboratory experiment was conducted with the objective of augmenting the mechanical properties of glass ionomer cement (GIC) via altering the composition of GIC luting powder through the introduction of micron-sized silanized glass fibres (GFs). Experimental GICs were prepared through the addition of two concentrations of GFs (0.5% and 1.0% by weight) to the powder of commercially available GIC luting materials. The effect of GF in set GIC was internally evaluated using micro-CT while the mechanical attributes such as nano hardness (nH), elastic modulus (EM), compressive strength (CS), and diametral tensile strength (DTS) were gauged. Additionally, the physical properties such as water solubility and sorption, contact angle (CA), and film thickness were evaluated. Reinforced Ketac Cem Radiopaque (KCR) GIC with 0.5 wt.% GF achieved improved nH, EM, CS, and DTS without affecting the film thickness, CA or internal porosity of the set GIC cement. In contrast, both GF-GIC formulations of Medicem (MC) GIC showed the detrimental effect of the GF incorporation. Reinforcing KCR GIC with 0.5 wt.% silanized GFs could improve the physical and mechanical attributes of luting material. Silanized GF, with optimal concentration within the GIC powder, can be used as a functional additive in KCR GIC with promising results.