Artificial intelligence (AI) is a contemporary, information-driven innovative technology. Prosthetic dentistry, also known as prosthodontics, is the restoration and reconstruction of missing teeth utilizing implants for permanent and removable prostheses. It enhances healthy soft and hard tissues, promoting oral health. This study examined the use of artificial intelligence in prosthodontics to diagnose abnormalities and create patient-specific prostheses. Two researchers searched Google Scholar, Scopus, PubMed/MEDLINE, EBSCO host, Science Direct, and Web of Science (MEDLINE, WOS, and KJD). Articles on AI in English were reviewed. We also collected the following broad article aspects: research and control groups, assessment methodology, outcomes, and quality rankings. This methodological study examined AI use in prosthodontics using the latest scientific findings. The findings were statistically evaluated using ANOVA. Titles and abstracts revealed 172 AI-related dentistry studies, which were analyzed in this research. Thirty-eight papers were eliminated. According to the evaluation, AI was found to have significantly increased in prosthodontics. Despite the vast number of studies documenting AI applications, the description of the data illustrated the latest breakthroughs in AI in prosthodontics, highlighting its use in automatically produced diagnostics, predicting analytics, and classification or verification tools.
Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis: An In Vitro Study - Article abstract #946624
Tobacco consumption in its different forms can affect the optical and surface properties of dental materials that are used in the oral cavity. Thus, the present study was conducted to evaluate the effects of two commercially available smokeless tobacco products on the color stability and surface roughness of denture base resins that were fabricated using three different techniques (CAD/CAM milling, 3D printing, and conventional heat polymerization). A total of 126 denture base resin specimens were fabricated using the three different manufacturing techniques (n = 42 each). Specimens from each group were further subdivided into three subgroups (n = 14 each) and immersed in three different immersion media (a khaini suspension, a tabbaq suspension, and artificial saliva). The differences in color and surface roughness were assessed according to data that were collected and statistically analyzed using SPSS version 24.0. The tabbaq smokeless tobacco was found to cause greatest changes in color and surface roughness; the effect was observed to be highest in the 3D-printed specimens followed by the conventional heat-polymerized and CAD/CAM milled specimens. The mean changes in color and surface roughness were the highest for the tabbaq smokeless tobacco followed by the khaini smokeless tobacco and the artificial saliva. Statistically significant (p-value < 0.05) differences were observed among all techniques and suspensions. We concluded that the mean changes in color and surface roughness were significantly higher for the 3D-printed dentures compared to the conventional heat-polymerized and CAD/CAM-milled dentures. Thus, the results of the present study strengthened the concept that tobacco in any form can lead to changes in the color and surface roughness of denture base materials.
Background: Sleep bruxism (SB) and obstructive sleep apnea syndrome (OSAS) are two sleep‐related conditions that have been associated with significantly conflicting results in literature. Understanding the prevalence of bruxism among OSA patients is crucial for identifying possible comorbidities and optimising treatment strategies.Objective: This systematic review aimed at analysing the prevalence of SB in OSAS sufferers and understanding the association between the two.Methods: Five online databases were searched for relevant articles in accordance with the PRISMA guidelines for conduction of systematic reviews. Studies reporting the prevalence of bruxism in OSAS patients and diagnosed through clinical assessments or polysomnography were included. Data extraction and quality assessment were performed independently by two reviewers. Methodological quality of the included studies was assessed using Risk of Bias In Non‐randomised Studies of Interventions (ROBINS‐I).Results: A thorough search of literature yielded only two studies were eligible for this review. SB was found to be significantly present in the OSAS group. Despite methodological variations, the majority of studies reported higher rates of bruxism in OSAS patients compared to the general population or control groups.Conclusion: The results of this systematic review point to a significant association between bruxism and obstructive sleep apnea. Further research is required to determine a more precise prevalence rate and investigate the potential therapeutic implications of the bruxism‐OSAS association that uses a standardised assessment techniques and larger sample sizes.
The aim of this study is to investigate the combined effect of a digital manufacturing technique (subtractive vs. additive), preparation taper (10° vs. 20° TOC), and finish line (chamfer vs. shoulder) on the marginal adaptation of temporary crowns following cementation with a compatible temporary cement. Four mandibular first molar typodont teeth were prepared for full coverage crowns with standard 4 mm preparation height as follows: 10° TOC with the chamfer finish line, 10° TOC with the shoulder finish line, 20° TOC with the chamfer finish line and 20° TOC with the shoulder finish line. Each of the four preparation designs were subdivided into two subgroups to receive CAD/CAM milled and 3D-printed crowns (n = 10). A total of 80 temporary crowns (40 CAD/CAM milled and 40 3D-printed) were cemented to their respective die using clear temporary recement in the standard cementation technique. The samples were examined under a stereomicroscope at ×100 magnification following calibration. Linear measurements were performed at seven equidistant points on each axial surface and five equidistant points on each proximal surface. One-way ANOVA analysis and Tukey HSD (Honestly Significance Difference) were performed. The best marginal fit was seen in group 8, while the poorest fit was noted in group 2. Shoulder finish lines and 10° TOC resulted in higher marginal gaps, especially in CAD/CAM milled group. The selection of 3D-printed crowns may provide a better marginal fit within the range of clinical acceptability. Marginal gaps were within clinical acceptability (50 and 120 µm) in all groups except group 2.
This study determined the influence of surface treatment and protracted ageing on the shear bond strength (SBS) of orthodontic brackets bonded to CADCAM (milled) and 3D-printed polymethylmethacrylate (PMMA) provisional crowns (PCs). Eighty disc-shaped specimens [forty milled (CopraTemp WhitePeaks) [group (Gp) M] and forty printed (Asiga DentaTooth) (Gp P)] were divided into eight subgroups (Gp) based on surface treatment [no treatment (control) (Gp MC and Gp PC), coarse diamond (Gp MCD and Gp PCD), fine diamond (Gp MFD, and GP PFD) and sandblast (Gp MSB and Gp PSB)]. Orthodontic brackets were bonded (Assure Plus, Transbond XT), thermocycled (2200 cycles), and tested for SBS and failure (Adhesive Remnant Index) (ARI). Statistical tests included analysis of variance (ANOVA); Kruskal–Wallis (ARI ranks); and post hoc (Tukey, Dunn, and Bonferroni) for determining group differences at predetermined probability p-values less than 0.05. SBS was significantly increased in Gp MSB (15.51 Mpa) and Gp PSB (14.11 Mpa), while the coarse diamond subgroups yielded the lowest mean SBS values [Gp MCD (11.28 Mpa) and Gp PCD (11.62 Mpa)]. The SBS of subgroups MFD, MSB, PCD, and PSB showed significant differences from those of their respective controls (Gp MC and Gp PC). Low ARI scores were observed in Gp MC (0.40) and Gp MSB (0.80), while higher scores were observed in Gp PCD (2.10). Both milled and printed PCs fulfil the clinical criteria of the minimum SBS for orthodontic brackets for long-term use. However, milled PC has better SBS and low ARI scores, which make it more clinically feasible for orthodontic treatments.