Tiago Coelho-Magalhães

Dr. Tiago Coelho-Magalhães

Universidade Federal de Minas Gerais (UFMG)
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Tiago Coelho-MagalhãesTiago Coelho-Magalhães
Tiago Coelho-Magalhães
EFEmerson Fachin-Martins
Emerson Fachin-Martins
Andressa SilvaAndressa Silva
Andressa Silva
CCChristine Azevedo Coste
Christine Azevedo Coste
HMHenrique Resende Martins
Henrique Resende Martins
Since the first Cybathlon 2016, when twelve teams competed in the FES bike race, we have witnessed a global effort towards the development of stimulation and control strategies to improve FES-assisted devices, particularly for cycling, as a means to practice a recreational physical activity. As a result, a set of technical notes and research paved the way for many other studies and the potential behind FES-assisted cycling has been consolidated. However, engineering research needs instrumented devices to support novel developments and enable precise assessment. Therefore, some researchers struggle to develop their own FES-assisted devices or find it challenging to implement their instrumentation using commercial devices, which often limits the implementation of advanced control strategies and the possibility to connect different types of sensor. In this regard, we hypothesize that it would be advantageous for some researchers in our community to enjoy access to an entire open-source FES platform that allows different control strategies to be implemented, offers greater adaptability and power capacity than commercial devices, and can be used to assist different functional activities in addition to cycling. Hence, it appears to be of interest to make our proprietary electrical stimulation system an open-source device and to prove its capabilities by addressing all the aspects necessary to implement a FES cycling system. The high-power capacity stimulation device is based on a constant current topology that allows the creation of biphasic electrical pulses with amplitude, width, and frequency up to 150 mA, 1000 µs, and 100 Hz, respectively. A mobile application (Android) was developed to set and modify the stimulation parameters of up to eight stimulation channels. A proportional-integral controller was implemented for cadence tracking with the aim to improve the overall cycling performance. A volunteer with complete paraplegia participated in the functional testing of the system. He was able to cycle indoors for 45 min, accomplish distances of more than 5 km using a passive cycling trainer, and pedal 2400 m overground in 32 min. The results evidenced the capacity of our FES cycling system to be employed as a cycling tool for individuals with spinal cord injury. The methodological strategies used to improve FES efficiency suggest the possibility of maximizing pedaling duration through more advanced control techniques.

18 July 2025 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
Tiago Coelho-MagalhãesTiago Coelho-Magalhães
Tiago Coelho-Magalhães
CCChristine Azevedo Coste
Christine Azevedo Coste
FBFrançois Bailly
François Bailly
In this paper, an existing physiological muscle model that predicts muscular force in response to electrical stimulation is adapted to be compatible with gradient-based optimization, in particular with numerical optimal control/estimation problems. The objective is to integrate biomechanical models with those that correlate muscle force generation with electrical pulses from a physiological perspective, with the aim of achieving optimal stimulation patterns in activities assisted by functional electrical stimulation. To this end, the activation dynamics of the original model, initially constrained to a stimulation train of predefined and constant length, is reformulated to account for stimulation sequences that dynamically change over time. This is typically necessary to simulate complex motions, which would otherwise be impossible to achieve with the earliest formulation. To identify the model parameters, experimental torque data of 3 participants with spinal cord injury performing electrically evoked isometric quadriceps contractions at different knee angles are used. We then employ an optimal control framework to demonstrate the model’s ability to predict knee torques and the possibility of achieving optimized stimulation patterns in simulation for controlling muscle force and knee extension. Our results reveal that the identified model allows accurate prediction of knee torque and optimization of stimulation patterns while satisfying the system’s dynamics at the skeletal and physiological muscle levels. This proof of concept is a first step towards physiological muscle model-based control of functional electrical stimulation to achieve movements that best exploit an individual’s physiological and biomechanical characteristics.

15 April 2022
Verified
Book Chapter
Closed access
PDF file
Tiago Coelho-MagalhãesTiago Coelho-Magalhães
Tiago Coelho-Magalhães
AVA. F. Vilaça-Martins
A. F. Vilaça-Martins
PAP. A. Araújo
P. A. Araújo
HRH. Resende-Martins
H. Resende-Martins