Electrical demand is continuously increasing due to technologies, and hence the supply-demand gap is also increasing. Under such circumstances, Demand Side management is applied to manage the load demand and minimize the energy consumption. The objective of this paper proposes a fuzzy multi criterion decision-making system as an intelligent system for demand side management technique for efficient energy and energy saving in industrial building.
With the rapid growth of isolated micro-grids, combined heating and power (CHP) can be integrated with photovoltaic (PV) system. The integration of CHP-PV systems has a tremendous potential to increase system reliability and efficiency as well as reduce energy consumption and CO2 emission. However, the operating models require considerable analysis due to the uncertainty load demand, so it is not easy to apply the models in order to simulate the current trend of baseline systems. In this paper, we developed models based on optimum clustering data to perform the behavior of CHP-PV using the integrating of accelerated particle swarm optimization (APSO) and fuzzy subtractive clustering (FSC). The objective of the APSO algorithm is to tune the parameters of data clustering-based FSC using proportional integral (PI) controller. The paper’s main goal is the minimal total energy and fuel consumption without compromising load demand of cooling. The proposed model interacts to the energy by gas turbine generators (GTGs) and PVs system. Also, it subdivides cooling load with the use of the partial load condition according to the outdoor weather. A case study of Universiti Teknologi Petronas (UTP), Malaysia was used to investigate its CHP plant. The model is validated using actual data obtained from University CHP plant. The results demonstrate that the proposed optimum system including CHP, PV, and storage systems is outperformed on the baseline system and basic CHP models. The proposed optimum models save 7 % and reduce 4.72 % of total daily electrical and steam production, respectively. Also, the optimal system is kept cooling demand satisfied.
Optimal operation is an important aspect of energy efficiency that can be employed to reduce power consumption. In cooling systems, the chillers consume a large amount of electricity, especially if they are not optimally operated, therefore, they cannot produce the required or rated cooling load capacity. The objective of this paper is to improve coefficient of performance (COP) for the operation of chillers and to reduce power consumption. Two contributions in this work are: (1) the prediction of a model by using Adaptive Neuro-Fuzzy Inference System (ANFIS)-based Fuzzy Clustering Subtractive (FCS), and (2) the classification and optimization of the predicted models by using an Accelerated Particle Swarm Optimization (APSO) algorithm. Particularly, in contribution (1), two models are developed to predict/assess power consumption and cooling load capacity. While in contribution (2), the predictive model’s data obtained are used to classify the operating performance of the chiller and to optimize the model in order to reduce power consumption and cooling capacity. Therefore, data classification by APSO is used to enhance the coefficient of performance (COP). The proposed technique reduces the total power consumption by 33.2% and meets the cooling demand requirements. Also, it improves the cooling performance based on COP, thus resulting in a 15.95% increase in efficiency compared to the existing cooling system. The studied ANFIS-based FCS outperforms the ANFIS-based fuzzy C-means clustering in terms of the regression. Then, the algorithm-based classifier APSO has better results compared to the conventional particle swarm optimization (PSO). The data was acquired from the District Cooling System (DCS) at the Universiti Teknologi Petronas (UTP) campus in Malaysia.
30 November 2018 in Journal of Physics: Conference Series
A brain–computer interface (BCI) provides a link between the human brain and a computer. The EEG signal is nonlinear and non-stationary. Feature extraction is one of the most important steps in any BCI system; as such, enhancement to the existing methods has been incorporated in this work. For this, we propose a four-class movement imaginations of the right hand, left hand, both hands, and both feet, and develop feature extraction methods utilizing an intelligent method based on intrinsic time-scale decomposition (ITD) and Artificial neural networks (ANN). Based on the processed electroencephalography (EEG) data recorded from nine subjects, ITD accurately classified and discriminated the four classes of motor imagery; the average accuracy achieved is 92.20%.
This paper discusses the optimal energy management of chiller plant. Two intelligent approaches have been employed. Fuzzy is used to adjust the set-point and, while PSO is utilized to optimize the objective function after setting by Fuzzy. Moreover, Fuzzy is also utilized to adjust weighting factors in order to find the best values for the PSO local and global. This will improve PSO performance. The proposed method was combined two levels as Fuzzified PSO, and the model has been simulated and validated by a real case study which consists of 5 electric-driven chillers. The results have shown that the effectiveness of the proposed method compared to the conventional one, and it also has demonstrated a better power saving.