Daniela Michálková

Dr. Daniela Michálková

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
DMDaniela Michálková
Daniela Michálková
PDPavol Durica
Pavol Durica
Current environmental crisis calls for sustainable solutions in the building industry. One of the possible solutions is to incorporate timber-framed constructions into designs. Among other benefits, these structures are well established in many countries, originating in traditional building systems. This paper focuses on experimental timber-frame walls. Different wall assemblies vary in thermal insulation materials and their combinations. We investigated ten experimental wall structures that have been exposed to natural external boundary conditions since 2015. The emphasis was on their state in terms of visual deterioration, mass moisture content, and thermal conductivity coefficient. We detected several issues, including defects caused by inappropriate realization, causing local moisture increase. Material settlement in loose-fill thermal insulation was another issue. Concerning was a significant change in the thermal conductivity of wood fiber insulation, where the current value almost doubled in one case compared to the design value determined by the producer.

15 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
RPRadoslav Ponechal
Radoslav Ponechal
PKPeter Kotes
Peter Kotes
DMDaniela Michálková
Daniela Michálková
Jakub KraľovanecJakub Kraľovanec
Jakub Kraľovanec
FBFrantišek Bahleda
František Bahleda
In the case of existing prestressed concrete structures, information about the actual state of prestressing is an important basis for determining their load-carrying capacity, as well as remaining service lifetime. This is even more important in the case of existing prestressed concrete bridges, which are exposed to a more aggressive environment than the other prestressed concrete structures. The level of prestressing is affected and reduced by prestress losses at a given time. In calculating the internal forces and stresses, required for the assessment of the Ultimate Limit State and the Serviceability Limit State, it is necessary to know not only the prestressing level but also the cross-sectional area of the prestressing steel (wire, strand or cable), which can change in time due to corrosion. In practice, in the case of the pre-tensioned concrete members, it has often happened in the past that cable ducts have been grouted only partially, or not at all, due to poor grouting technology. Experts did not realize what this could cause in the future—the penetration of water with aggressive agents directly into the cable duct and consequently corrosion of the prestressing steel, which means not increased protection of the steel, but rather acceleration of degradation. On the other hand, in many cases, corrosion also occurs in ducts that are not grouted and no water has entered them. This paper deals with this phenomenon—the formation of corrosion of prestressing steel in cable ducts in ungrouted ducts due to moisture. This problem was investigated experimentally and numerically in the simulation program ESP-r. Experimental measurements and numerical simulations have shown that the water vapor condenses in the cable ducts, which can subsequently cause corrosion of the prestressing steel.

6 March 2023 in Buildings
Verified
Journal Article
Open access
PDF file
PKPeter Kysela
Peter Kysela
RPRadoslav Ponechal
Radoslav Ponechal
DMDaniela Michálková
Daniela Michálková
The airtightness of buildings is an essential topic regarding energy preservation. The development of new and more sophisticated materials and technology approaches is inevitable. Uncontrolled infiltration is undesirable in buildings with lower energy demands with regulated ventilation. Envelope structure, building method, quality, and others are the main factors influencing the airtightness of the building. However, the correlation between airtightness and climatic factors is less known and researched. This paper comprises measurements of a critical timber-house corner in climatic chambers. It captures the correlation between airtightness and gradual temperature and relative humidity adjustments, simulated from the exterior side. The initial timber moisture content was 12%, and during the experiment it increased with the exterior conditions to 18%. Afterward, we simulated conditions causing a humidity decrease while measuring airtightness. The drying process caused a decrement in airtightness by 18%. In addition to this experiment, this paper also analyses two methods of an airtight membrane connection—constricting or taping the contact. The discrepancy between those two methods was more than 21% in favor of tape.

21 December 2022 in Acta Polytechnica CTU Proceedings
Verified
Journal Article
Open access
PDF file
DMDaniela Michálková
Daniela Michálková
PĎPavol Ďurica
Pavol Ďurica
The construction industry's focus on a low-carbon economy will result in the need for a deeper examination of natural-based building materials. From an environmental point of view, the benefits of these materials are undeniable. However, it is necessary to consider their shortcomings in other areas of design in terms of building thermal engineering. This article observes and evaluates a wall designed for a wooden building with almost zero energy demand in year-round operation and subsequent assessment in confrontation with a different composition, seemingly more advantageous in thermal resistance and humidity regime. These assemblies are under long-term examination within the pavilion research of the authors' workplace, in laboratory conditions from the interior side. At the same time, they are exposed to the realistic boundary conditions of the external environment. The paper includes an environmental assessment of two compositions, variating in the used material. The research shows that the wall composition of natural materials is more advantageous from an ecological perspective and can also show favourable effects in terms of temperature and relative humidity regulation.

26 June 2023 in Buildings
Verified
Journal Article
Open access
PDF file
DMDaniela Michálková
Daniela Michálková
PDPavol Durica
Pavol Durica
Loose-fill thermal insulations in timber-frame structures are designed to provide efficient thermal protection with the ability to fill intricate details. In a previous study, we detected several air cavities formed in timber-framed wall samples filled with loose-fill mineral fiber insulation. This discovery led us to retrofit the walls by adding appropriate insulation, thus enabling us to evaluate the importance of proper amendment. This paper focuses on a wall fragment with an 80 mm high air gap at the top and a 30 mm high cavity in the middle of the wall height. The following paper compares data collected before the discovery and after the replenishment (refill of air gaps with additional insulation), evaluating potential thermal performance improvement. We were able to quantify the impact of these defects on the external wall exposed to realistic conditions. Based on temperature and relative humidity measurements, the results show significant advancement in the middle of wall thickness with an 8 °C and 45% difference. The results show that although this defect did not directly affect the energy balance of the building, it significantly increases the risk of mold growth due to thermal bridging.

15 September 2021
Verified
Book Chapter
Closed access
PDF file
DMDaniela Michálková
Daniela Michálková
PĎPavol Ďurica
Pavol Ďurica